Phoenix NBC-R4 Series Industrial Connectors Selection Guide: Multi-Interface & Protocol-Compliant Cable Assemblies
Opening: Customizable Industrial Cable Assemblies for Signal/Ethernet Transmission
The Phoenix NBC-R4 series is a portfolio of pre-terminated industrial cable assemblies with R4-series interfaces (RC/OC/ACS/AC/AC-10G/AC1), covering cable lengths from 0.3m to 20m and diverse protocol codings (93B/93C/93E/93M/94B/94F/94G/BC5/BC6A). Designed for industrial automation, Ethernet communication, and sensor/actuator interconnection, these assemblies feature IP67 protection, shielded designs, and protocol-specific optimization, ensuring stable transmission in harsh environments. This guide structures part number-model correspondence, core parameters, and scenario recommendations for efficient selection.
I. Core Advantages: Why Choose the NBC-R4 Series?
- Pre-terminated convenience: Factory-assembled and tested, eliminating on-site wiring errors and reducing installation time by 60% compared to field-terminated cables.
- Multi-interface compatibility: Covers RC (relay connection), OC (open-circuit), ACS (advanced communication), AC (standard Ethernet), and AC-10G (10G Ethernet) interfaces, adapting to signal and high-speed data transmission needs.
- Protocol-specific coding: Supports B/C/E/F/G/M codings (matching PROFINET, Ethernet, and custom industrial protocols) and BC5/BC6A proprietary specifications, ensuring seamless integration with control systems.
- Flexible cable lengths: 0.3m (compact cabinets) to 20m (long-distance field wiring), meeting different installation distance requirements.
- Industrial-grade durability: IP67 waterproof/dustproof, -40°C to +85°C operating temperature, shielded against electromagnetic interference (EMI), and anti-vibration for factory floor reliability.
II. Complete Product Selection Table (Part Number + Model + Core Information)
1. R4RC Sub-series: Relay Connection Cable Assemblies
Optimized for relay control circuit wiring, with 10m fixed length and 93B coding for general signal transmission.
| Part Number | Complete Model | Core Parameters | Application Scenario |
|---|---|---|---|
| 1408976 | NBC-R4RC/10,0-93B/R4RC | Interface: R4RC (relay connection); Length: 10.0m; Coding: 93B; Feature: Relay circuit-specific | 10m long-distance relay control signal transmission (e.g., PLC-to-relay module wiring in large workshops) |
2. R4OC Sub-series: Open-Circuit Signal Cable Assemblies
Suitable for open-circuit sensor/actuator signal transmission, with BC5/BC6A proprietary coding and cable lengths from 1.0m to 15.0m.
| Part Number | Complete Model | Core Parameters | Application Scenario |
|---|---|---|---|
| 1227563 | NBC-R4OC/3,0-BC5/R4OC | Interface: R4OC (open-circuit); Length: 3.0m; Coding: BC5; Feature: Proprietary open-circuit signal | 3m BC5-coded open-circuit sensor wiring (e.g., proximity sensor to PLC input) |
| 1227580 | NBC-R4OC/2,0-BC6A/R4OC | Interface: R4OC; Length: 2.0m; Coding: BC6A; Feature: BC6A proprietary protocol | 2m BC6A-coded actuator signal transmission (e.g., small solenoid valve control) |
| 1227562 | NBC-R4OC/2,0-BC5/R4OC | Interface: R4OC; Length: 2.0m; Coding: BC5 | 2m compact BC5-coded open-circuit signal wiring (e.g., control cabinet internal sensor connection) |
| 1227570 | NBC-R4OC/15,0-BC5/R4OC | Interface: R4OC; Length: 15.0m; Coding: BC5 | 15m long-distance BC5-coded field sensor wiring (e.g., outdoor conveyor belt proximity sensors) |
| 1227561 | NBC-R4OC/1,5-BC5/R4OC | Interface: R4OC; Length: 1.5m; Coding: BC5 | 1.5m short-distance BC5-coded signal transmission (e.g., indicator light to relay wiring) |
| 1227560 | NBC-R4OC/1,0-BC5/R4OC | Interface: R4OC; Length: 1.0m; Coding: BC5 | 1m ultra-compact BC5-coded open-circuit wiring (e.g., narrow cabinet sensor feedback) |
3. R4ACS Sub-series: Advanced Communication Signal Cable Assemblies
Designed for high-reliability communication signals, with 93B/93C coding and lengths from 0.5m to 20m, suitable for industrial fieldbus and sensor networks.
| Part Number | Complete Model | Core Parameters | Application Scenario |
|---|---|---|---|
| 1112856 | NBC-R4ACS/5,0-93B/R4ACS | Interface: R4ACS (advanced communication); Length: 5.0m; Coding: 93B | 5m 93B-coded advanced communication signal wiring (e.g., PROFINET sensor network) |
| 1113327 | NBC-R4ACS/20,0-93B/R4ACS | Interface: R4ACS; Length: 20.0m; Coding: 93B | 20m long-distance 93B-coded fieldbus communication (e.g., workshop-wide sensor data transmission) |
| 1112820 | NBC-R4ACS/2,0-93B/R4ACS | Interface: R4ACS; Length: 2.0m; Coding: 93B | 2m compact 93B-coded advanced signal wiring (e.g., control cabinet internal fieldbus connection) |
| 1113329 | NBC-R4ACS/10,0-93B/R4ACS | Interface: R4ACS; Length: 10.0m; Coding: 93B | 10m medium-distance 93B-coded sensor network wiring (e.g., production line sensor array) |
| 1112817 | NBC-R4ACS/1,0-93B/R4ACS | Interface: R4ACS; Length: 1.0m; Coding: 93B | 1m ultra-short 93B-coded advanced signal transmission (e.g., PLC-to-gateway wiring) |
| 1112939 | NBC-R4ACS/0,5-93C/R4ACS | Interface: R4ACS; Length: 0.5m; Coding: 93C | 0.5m 93C-coded high-precision communication wiring (e.g., IoT edge module signal connection) |
| 1112785 | NBC-R4ACS/0,5-93B/R4ACS | Interface: R4ACS; Length: 0.5m; Coding: 93B | 0.5m compact 93B-coded advanced signal wiring (e.g., narrow cabinet gateway-to-sensor connection) |
4. R4AC-10G Sub-series: 10G Ethernet Cable Assemblies
Optimized for high-speed 10G Ethernet communication, with 94F coding for high-bandwidth data transmission (e.g., industrial cameras, large-data sensors).
| Part Number | Complete Model | Core Parameters | Application Scenario |
|---|---|---|---|
| 1416125 | NBC-R4AC-10G/20,0-94F/R4AC-10G | Interface: R4AC-10G (10G Ethernet); Length: 20.0m; Coding: 94F; Feature: 10G high-speed | 20m long-distance 10G Ethernet wiring (e.g., workshop-wide industrial camera network) |
| 1422211 | NBC-R4AC-10G/1,5-94F/R4AC-10G | Interface: R4AC-10G; Length: 1.5m; Coding: 94F | 1.5m compact 10G Ethernet wiring (e.g., control cabinet internal camera-to-switch connection) |
| 1422209 | NBC-R4AC-10G/0,3-94F/R4AC-10G | Interface: R4AC-10G; Length: 0.3m; Coding: 94F | 0.3m ultra-short 10G Ethernet wiring (e.g., compact IoT gateway-to-Ethernet module connection) |
5. R4AC1 Sub-series: AC1-Type Ethernet Cable Assemblies (Blue-Coded)
Blue (BU) color-coded for critical Ethernet circuits, with 94G coding and lengths of 1.0m/5.0m for visual circuit differentiation.
| Part Number | Complete Model | Core Parameters | Application Scenario |
|---|---|---|---|
| 1413163 | NBC-R4AC1/5,0-94G/R4AC1-BU | Interface: R4AC1 (AC1-type Ethernet); Length: 5.0m; Coding: 94G; Color: BU (blue); Feature: Critical circuit identification | 5m blue-coded 94G-coded Ethernet wiring (e.g., emergency stop system communication circuit) |
| 1413160 | NBC-R4AC1/1,0-94G/R4AC1-BU | Interface: R4AC1; Length: 1.0m; Coding: 94G; Color: BU | 1m blue-coded 94G-coded compact Ethernet wiring (e.g., control cabinet critical communication link) |
6. R4AC/R4ACR Sub-series: Standard Ethernet Cable Assemblies
General-purpose Ethernet cable assemblies with diverse codings (93B/93E/93M/94B) and lengths of 5.0m/7.5m, suitable for standard industrial Ethernet networks.
| Part Number | Complete Model | Core Parameters | Application Scenario |
|---|---|---|---|
| 1424816 | NBC-R4AC/7,5-93B/R4AC | Interface: R4AC (standard Ethernet); Length: 7.5m; Coding: 93B | 7.5m medium-distance 93B-coded Ethernet wiring (e.g., production line PLC-to-switch connection) |
| 1408952 | NBC-R4AC/5,0-94B/R4AC | Interface: R4AC; Length: 5.0m; Coding: 94B | 5m 94B-coded Ethernet wiring (e.g., industrial HMI-to-PLC communication) |
| 1420383 | NBC-R4AC/5,0-93M/R4ACR | Interface: R4ACR (standard Ethernet, R-type); Length: 5.0m; Coding: 93M | 5m 93M-coded Ethernet wiring (e.g., custom protocol industrial device communication) |
| 1408935 | NBC-R4AC/5,0-93E/R4AC | Interface: R4AC; Length: 5.0m; Coding: 93E | 5m 93E-coded PROFINET Ethernet wiring (e.g., PROFINET IO device-to-controller connection) |
| 1408970 | NBC-R4AC/5,0-93B/R4AC | Interface: R4AC; Length: 5.0m; Coding: 93B | 5m standard 93B-coded Ethernet wiring (e.g., general workshop sensor-to-switch connection) |
III. NBC-R4 Series Nomenclature Decoding
NBC-R4[Interface Type]/[Cable Length]-[Coding/Specification]/[Tail Suffix]
- Interface Type:
- RC = Relay connection (control circuit);
- OC = Open-circuit (sensor/actuator signal);
- ACS = Advanced communication (fieldbus/high-reliability signal);
- AC-10G = 10G high-speed Ethernet;
- AC1 = AC1-type Ethernet (blue-coded);
- AC/ACR = Standard Ethernet (ACR = R-type variant).
- Cable Length: 0.3m/0.5m/1.0m/1.5m/2.0m/3.0m/5.0m/7.5m/10.0m/15.0m/20.0m (decimal separator: comma for European standard).
- Coding/Specification:
- 93B/93C/93E/93M = Industrial protocol coding (93E for PROFINET, 93B for general signal);
- 94B/94F/94G = Ethernet coding (94F for 10G, 94G for AC1-type);
- BC5/BC6A = Phoenix proprietary open-circuit signal coding.
- Tail Suffix:
- Matching interface type (e.g., R4RC/R4OC) for consistency;
- BU = Blue color (critical circuit identification for AC1 sub-series);
- R4ACR = R-type standard Ethernet variant.
IV. 3-Step Quick Selection Technique
Step 1: Determine Interface Type Based on Transmission Need
- Relay control circuits: R4RC (only 1408976, 10m 93B) → relay module wiring;
- Open-circuit sensor/actuator signals: R4OC (BC5/BC6A coding, e.g., 1227560) → proximity/photoelectric sensor wiring;
- Advanced communication/fieldbus: R4ACS (93B/93C coding, e.g., 1112785) → high-reliability sensor networks;
- 10G high-speed Ethernet: R4AC-10G (94F coding, e.g., 1416125) → industrial cameras/large-data devices;
- Critical Ethernet circuits (visual identification): R4AC1 (BU blue, 94G coding, e.g., 1413160) → emergency communication links;
- Standard industrial Ethernet: R4AC/R4ACR (93B/93E/93M/94B coding, e.g., 1408970) → PLC/HMI/IO device networking.
Step 2: Match Cable Length to Installation Distance
- Ultra-short (compact cabinets): 0.3m (1422209) / 0.5m (1112785) → internal module-to-module wiring;
- Short-distance (cabinet internal): 1.0m (1227560) / 1.5m (1422211) → sensor-to-PLC wiring;
- Medium-distance (workstation): 2.0m (1227562) / 3.0m (1227563) / 5.0m (1112856) → production line device interconnection;
- Long-distance (workshop-wide): 7.5m (1424816) / 10m (1408976) / 15m (1227570) / 20m (1113327) → cross-workshop sensor/network wiring.
Step 3: Select Coding for Protocol Compatibility
- PROFINET: 93E coding (1408935 R4AC) → PROFINET IO device communication;
- 10G Ethernet: 94F coding (1416125 R4AC-10G) → high-bandwidth data transmission;
- Phoenix proprietary open-circuit: BC5/BC6A (1227560 R4OC) → matching Phoenix sensors/actuators;
- General signal/fieldbus: 93B coding (1112785 R4ACS) → most industrial control systems;
- Critical Ethernet (visual ID): 94G + BU blue (1413160 R4AC1) → emergency/key circuits;
- Custom protocol: 93M coding (1420383 R4ACR) → legacy/custom industrial devices.
V. Recommended Industry-Scenario Combinations
| Industry | Typical Scenario | Recommended Model Combination |
|---|---|---|
| Factory Automation (PROFINET Network) | 5m PROFINET IO device-to-controller wiring + 2m cabinet internal sensor connection | 1408935 (NBC-R4AC/5,0-93E/R4AC) + 1227562 (NBC-R4OC/2,0-BC5/R4OC) |
| Industrial Machine Vision (10G Ethernet) | 20m workshop camera network + 0.3m cabinet camera-to-switch wiring | 1416125 (NBC-R4AC-10G/20,0-94F/R4AC-10G) + 1422209 (NBC-R4AC-10G/0,3-94F/R4AC-10G) |
| Critical Safety System (Blue-Coded Ethernet) | 5m emergency communication link + 1m cabinet critical network wiring | 1413163 (NBC-R4AC1/5,0-94G/R4AC1-BU) + 1413160 (NBC-R4AC1/1,0-94G/R4AC1-BU) |
| Long-Distance Sensor Network (Advanced Communication) | 20m workshop sensor data transmission + 0.5m cabinet gateway connection | 1113327 (NBC-R4ACS/20,0-93B/R4ACS) + 1112785 (NBC-R4ACS/0,5-93B/R4ACS) |
| Relay Control Circuit (Long-Distance) | 10m PLC-to-relay module wiring in large workshop | 1408976 (NBC-R4RC/10,0-93B/R4RC) + 1424816 (NBC-R4AC/7,5-93B/R4AC) |
VI. Selection Pitfall Avoidance Guide
- Interface type mismatch: 10G Ethernet using R4AC (standard Ethernet) → Choose R4AC-10G (1416125) for 10G bandwidth support.
- Coding incompatibility: PROFINET system using 93B coding → Select 93E coding (1408935 R4AC) for PROFINET protocol compatibility.
- Cable length error: 20m workshop wiring using 5m cable → Opt for 10m/15m/20m models (1408976/1227570/1113327) to avoid signal attenuation.
- Critical circuit identification missing: Emergency communication using black cables → Use R4AC1 (BU blue, 1413160) for visual differentiation.
- Proprietary protocol neglect: Phoenix open-circuit sensors using 93B coding → Choose BC5/BC6A coding (1227560 R4OC) for matching sensor signals.
- High-speed data oversight: Industrial cameras using standard Ethernet (R4AC) → Select R4AC-10G (1416125) for 10G high-bandwidth transmission.
- Compact cabinet wiring error: 0.3m internal wiring using 1m cable → Use 0.3m (1422209) / 0.5m (1112785) models to save space and reduce cable clutter.
Conclusion: Select the Right NBC-R4 Cable Assembly for Reliable Industrial Transmission
The Phoenix NBC-R4 series provides pre-terminated, protocol-compliant cable assemblies for signal, communication, and Ethernet transmission, with diverse interfaces, lengths, and codings adapting to industrial automation, machine vision, and safety system needs.