Phoenix CABLE Series Industrial Connection Cables Selection Guide

Opening: Pre-Terminated Cables for Reliable Controller-I/O & Device Interconnection

The Phoenix CABLE series covers factory-pre-terminated industrial connection cables for linking controllers, I/O modules, and field devices, including FLK (FLK50/20/16/14/10), FCN40 (controller-specific), and DB37F (D-sub interface) sub-series. These cables feature fixed wire gauge (0.14mm²/0.4mm²/4×14/1×50), diverse lengths (0.05m–10m), and compatibility with mainstream controllers (Schneider M340, Siemens S7, Mitsubishi MEL), eliminating on-site wiring errors and improving connection stability. This guide organizes part number-model correspondence, core parameters, and scenario recommendations for efficient selection.


I. Core Advantages of the CABLE Series

  1. Factory pre-terminated: Precision crimped and tested, reducing 80% of on-site wiring time and avoiding manual connection faults.
  2. Controller-specific compatibility: Tailored for Schneider M340, Siemens S7, Mitsubishi MEL, and other mainstream PLCs, achieving plug-and-play integration.
  3. Flexible length coverage: Ranges from ultra-short (50mm for cabinet internal) to long-distance (10m for field device connection), adapting to different installation spaces.
  4. Stable signal transmission: Fixed 0.14mm²/0.4mm² signal wire gauge ensures low attenuation, while multi-core (4×14/1×50) power cables meet medium-current transmission needs.
  5. Industrial-grade durability: Wear-resistant outer sheath, -25°C to +60°C operating temperature, and anti-vibration design for harsh factory environments.

II. Complete Product Classification & Parameter Table

1. FLK Series (FLK50/20/16/14/10, Open-End OE)

Suitable for general I/O module and field device wiring, with open-end (OE) design for on-site terminal connection, and 0.14mm² signal wire gauge for low-current signal transmission.

Part Number Complete Model Interface Type Wire Gauge Length Key Features Application Scenario
FLK50 Sub-series            
2305392 CABLE-FLK50/OE/0,14/300 FLK50 0.14mm² 300mm Open-end (OE) FLK50 I/O module short-distance cabinet internal wiring
2305376 CABLE-FLK50/OE/0,14/200 FLK50 0.14mm² 200mm Open-end FLK50 module compact cabinet connection
2314163 CABLE-FLK50/0,14/HF/2,0M FLK50 0.14mm² 2.0m HF (high-frequency) FLK50 module high-frequency signal transmission (2m)
FLK20 Sub-series            
2305842 CABLE-FLK20/OE/0,14/600 FLK20 0.14mm² 600mm Open-end FLK20 I/O module medium-distance cabinet wiring
2305347 CABLE-FLK20/OE/0,14/300 FLK20 0.14mm² 300mm Open-end FLK20 module short-distance connection
2305334 CABLE-FLK20/OE/0,14/250 FLK20 0.14mm² 250mm Open-end FLK20 module ultra-compact cabinet wiring
2305321 CABLE-FLK20/OE/0,14/200 FLK20 0.14mm² 200mm Open-end FLK20 module minimal-space connection
FLK16 Sub-series            
2318211 CABLE-FLK16/OE/0,14/10,0M FLK16 0.14mm² 10.0m Open-end FLK16 module long-distance field device connection (10m)
2318172 CABLE-FLK16/OE/0,14/3,0M FLK16 0.14mm² 3.0m Open-end FLK16 module medium-distance workshop wiring (3m)
2318156 CABLE-FLK16/OE/0,14/2,0M FLK16 0.14mm² 2.0m Open-end FLK16 module 2m field connection
2318127 CABLE-FLK16/OE/0,14/0,5M FLK16 0.14mm² 0.5m Open-end FLK16 module cabinet internal short wiring (0.5m)
FLK14 Sub-series            
2305761 CABLE-FLK14/OE/0,14/50 FLK14 0.14mm² 50mm Open-end FLK14 module ultra-short cabinet internal connection (5cm)
2305774 CABLE-FLK14/OE/0,14/400 FLK14 0.14mm² 400mm Open-end FLK14 module 40cm medium-distance cabinet wiring
2305295 CABLE-FLK14/OE/0,14/300 FLK14 0.14mm² 300mm Open-end FLK14 module 30cm short-distance connection
2305279 CABLE-FLK14/OE/0,14/200 FLK14 0.14mm² 200mm Open-end FLK14 module 20cm compact cabinet wiring
FLK10 Sub-series            
2904075 CABLE-FLK10/OE/0,14/1,5M FLK10 0.14mm² 1.5m Open-end FLK10 module 1.5m workshop I/O connection

2. FCN40 Series (Controller-Specific, M340/S7/MEL Compatible)

Customized for brand controllers, with 4×14 (multi-core signal) and 1×50 (single-core power) wire specifications, supporting Schneider M340, Siemens S7, and Mitsubishi MEL systems.

Part Number Complete Model Core Specification Length Controller Compatibility Application Scenario
4×14 Multi-core Signal          
2321761 CABLE-FCN40/4X14/6,0M/M340 4×14 (multi-core signal) 6.0m Schneider M340 M340 controller 6m long-distance multi-signal I/O connection
2321745 CABLE-FCN40/4X14/3,0M/M340 4×14 3.0m Schneider M340 M340 controller 3m workshop multi-signal wiring
2321732 CABLE-FCN40/4X14/2,0M/M340 4×14 2.0m Schneider M340 M340 controller 2m cabinet-to-I/O module connection
2321185 CABLE-FCN40/4X14/1,0M/S7-OUT 4×14 1.0m Siemens S7 (output module) S7 controller 1m output module multi-signal wiring
1×50 Single-core Power          
2321664 CABLE-FCN40/1X50/3,0M/M340 1×50 (single-core power) 3.0m Schneider M340 M340 controller 3m medium-distance power supply for I/O modules
2321651 CABLE-FCN40/1X50/2,0M/M340 1×50 2.0m Schneider M340 M340 controller 2m cabinet internal I/O power connection
2903470 CABLE-FCN40/1X50/2,0M/IM/MEL 1×50 2.0m Mitsubishi MEL (input module) MEL controller 2m input module power supply
2321648 CABLE-FCN40/1X50/1,0M/M340 1×50 1.0m Schneider M340 M340 controller 1m short-distance I/O power wiring

3. DB37F Series (D-sub 37-Pin Interface, CS1112/CS1107 Compatible)

D-sub 37-pin female (DB37F) interface cables, with 2×IC14 cores and 0.4mm² wire gauge, for connecting to CS1112/CS1107 modules.

Part Number Complete Model Interface Type Core Specification Wire Gauge Controller/Module Compatibility Application Scenario
2903139 CABLE-DB37F-2IC14/0,4/CS1112 DB37F (D-sub 37-pin female) 2×IC14 0.4mm² CS1112 module CS1112 module dual-channel signal transmission
2903140 CABLE-DB37F-2IC14/0,4/CS1107 DB37F 2×IC14 0.4mm² CS1107 module CS1107 module dual-channel control signal wiring

III. CABLE Series Nomenclature Decoding

1. FLK Series Nomenclature

CABLE-FLK[Interface Size]/[Wire Gauge]/[Feature]/[Length]

  • Interface Size: 50/20/16/14/10 → Matches FLK I/O module interface specifications (larger numbers for more cores).
  • Wire Gauge: 0,14 → 0.14mm² signal wire for low-current data transmission.
  • Feature:
    • OE = Open-end (for on-site terminal crimping);
    • HF = High-frequency (for high-speed signal transmission).
  • Length: 50/200/300 (mm, without unit) or 2,0M/10,0M (meter, with M suffix), decimal separator is comma (European standard).

2. FCN40 Series Nomenclature

CABLE-FCN40/[Core Specification]/[Length]/[Controller Compatibility]

  • Core Specification:
    • 4X14 = 4-core 14-gauge (multi-channel signal transmission);
    • 1X50 = 1-core 50-gauge (medium-current power supply).
  • Length: 1,0M/2,0M/6,0M (meter).
  • Controller Compatibility:
    • M340 = Schneider M340 PLC;
    • S7-OUT = Siemens S7 output module;
    • IM/MEL = Mitsubishi MEL input module.

3. DB37F Series Nomenclature

CABLE-DB37F-[Core Count&Type]/[Wire Gauge]/[Module Compatibility]

  • Core Count&Type: 2IC14 = 2×IC14 dedicated signal cores.
  • Wire Gauge: 0,4 = 0.4mm² signal wire (higher current than 0.14mm²).
  • Module Compatibility: CS1112/CS1107 = Specific industrial control modules.

IV. 3-Step Quick Selection Technique

Step 1: Confirm Interface/Controller Type

  • General FLK I/O modules: Select corresponding FLK sub-series (FLK50 for 50-pin modules, FLK14 for 14-pin modules) based on module interface size.
  • Brand-specific PLCs:
    • Schneider M340 → FCN40 series with M340 suffix (e.g., 2321761 CABLE-FCN40/4X14/6,0M/M340);
    • Siemens S7 → FCN40 with S7-OUT suffix (2321185 CABLE-FCN40/4X14/1,0M/S7-OUT);
    • Mitsubishi MEL → FCN40 with IM/MEL suffix (2903470 CABLE-FCN40/1X50/2,0M/IM/MEL);
  • D-sub 37-pin modules: Choose DB37F series (2903139/2903140) matching CS1112/CS1107 modules.

Step 2: Match Core Specification to Transmission Need

  • Signal transmission: 0.14mm² (FLK series) or 0.4mm² (DB37F series) for low-current control/feedback signals; 4×14 (FCN40) for multi-channel signal integration.
  • Power supply: 1×50 (FCN40 series) for medium-current I/O module power transmission (e.g., 2321664 CABLE-FCN40/1X50/3,0M/M340).

Step 3: Select Length Based on Installation Distance

  • Cabinet internal (ultra-short): 50mm (2305761 FLK14) / 200mm (2305321 FLK20) to reduce cable clutter.
  • Cabinet-to-I/O (short/medium): 0.5m (2318127 FLK16) / 2m (2314163 FLK50) / 3m (2318172 FLK16) for workshop local wiring.
  • Field long-distance: 6m (2321761 FCN40) / 10m (2318211 FLK16) for cross-workshop device connection.

V. Recommended Industry-Scenario Combinations

Industry Typical Scenario Recommended Model Combination
Factory Automation (Schneider M340) M340 controller 6m multi-signal + 3m power I/O connection 2321761 (CABLE-FCN40/4X14/6,0M/M340) + 2321664 (CABLE-FCN40/1X50/3,0M/M340)
General I/O Module Wiring (FLK16) 10m field sensor + 0.5m cabinet internal connection 2318211 (CABLE-FLK16/OE/0,14/10,0M) + 2318127 (CABLE-FLK16/OE/0,14/0,5M)
Siemens S7 Output Module 1m multi-signal output wiring + FLK14 ultra-short cabinet connection 2321185 (CABLE-FCN40/4X14/1,0M/S7-OUT) + 2305761 (CABLE-FLK14/OE/0,14/50)
D-sub Module Control (CS1112/CS1107) Dual-channel signal transmission for CS1112/CS1107 2903139 (CABLE-DB37F-2IC14/0,4/CS1112) + 2903140 (CABLE-DB37F-2IC14/0,4/CS1107)

VI. Selection Pitfall Avoidance Guide

  1. Interface size mismatch: FLK50 module using FLK14 cable → Confirm module interface size (50/20/16/14/10) to ensure physical compatibility.
  2. Controller compatibility error: Siemens S7 using M340-suffix FCN40 cable → Select S7-OUT suffix (2321185) for S7, M340 suffix for Schneider systems.
  3. Core specification error: Power supply using 4×14 signal cable → Choose 1×50 (FCN40) for power transmission to avoid overheating.
  4. Length selection error: 10m field device using 2m cable → Opt for 10m (2318211 FLK16) or 6m (2321761 FCN40) to avoid signal attenuation from extended cables.
  5. High-frequency signal neglect: High-speed communication using standard FLK cable → Select HF-suffix (2314163 FLK50/0,14/HF/2,0M) for stable high-frequency transmission.

Conclusion: Select the Right CABLE Series for Stable Industrial Interconnection

The Phoenix CABLE series provides pre-terminated, controller-compatible connection solutions for FLK I/O modules, brand PLCs, and D-sub interface devices, with flexible length and core specifications adapting to cabinet internal, workshop local, and field long-distance wiring. 

Phoenix CABLE Series Industrial Connection Cables Selection Guide