Phoenix VAL-MS 320/275 Series Surge Protection Devices (SPD) Selection Guide
Opening: Targeted Overvoltage Protection for 320V/275V Low-Voltage Industrial Systems
The Phoenix VAL-MS 320 series is a 320V AC voltage-class surge protector (SPD) designed for industrial low-voltage power distribution, automation control, and terminal device overvoltage protection, with optional configurations (1+1/2/3/3+0/3+1/4-channel) and special functions (FM remote monitoring, UD universal design, ST screw terminals). The included VAL-MS 275/20 VF ST CRW is a 275V specialized model for compact, quick-wiring scenarios. This guide organizes part number-model correspondence, core parameters, and scenario recommendations to simplify SPD selection for different industrial systems.
I. Core Advantages of the VAL-MS 320/275 Series
- Wide configuration coverage: Supports single-phase (1+1), dual-channel (2), three-phase (3/3+0), and three-phase four-wire (3+1/4) systems, adapting to diverse industrial power architectures.
- Flexible functional extensions:
- FM: Built-in remote monitoring contact for fault status feedback (critical for unattended systems);
- UD: Universal design for multi-wiring compatibility (screw/spring terminals);
- ST: Screw terminals for secure, vibration-resistant connections;
- VF: Fork terminals for quick batch wiring (275V model exclusive).
- Industrial-grade reliability: IP20 protection, -40°C to +85°C operating temperature, and high surge current tolerance (20kA for 275V model), suitable for harsh factory environments.
- System-matched voltage: 320V for standard low-voltage industrial systems, 275V for special low-voltage equipment (e.g., precision sensors, compact control modules).
II. Complete Product Classification & Parameter Table
1. VAL-MS 320 Series (320V AC, Mainstream Configurations)
Classified by wiring configuration and special functions, covering single-phase to three-phase four-wire systems for different power and signal circuits.
| Category | Part Number | Complete Model | Core Parameters | Key Functions | Application Scenario |
|---|---|---|---|---|---|
| Basic Single-Phase/Dual-Channel | |||||
| 5772168 | VAL-MS 320 | Voltage: 320V AC; Configuration: Universal; Terminals: Standard | Basic overvoltage protection | General single-phase low-voltage equipment (e.g., indicator lights, small sensors) | |
| 2838843 | VAL-MS 320 ST | Voltage: 320V AC; Configuration: Universal; Terminals: ST (screw) | Secure screw-terminal connection | Vibration-prone single-phase equipment (e.g., conveyor belt sensor power) | |
| 2858315 | VAL-MS 320-UD ST | Voltage: 320V AC; Configuration: Universal; Feature: UD (universal design) + ST | Multi-wiring compatibility (screw/spring) | Mixed-terminal control cabinet single-phase protection | |
| 5772223 | VAL-MS 320/2 | Voltage: 320V AC; Configuration: 2-channel (dual-circuit) | Dual-circuit independent protection | Dual-group single-phase equipment (e.g., paired actuators) | |
| Single-Phase 1+1 (L+PE) | |||||
| 2804380 | VAL-MS 320/1+1 | Voltage: 320V AC; Configuration: 1+1 (L+PE) | Single-phase ground-protected SPD | Single-phase equipment with independent ground (e.g., laboratory precision instruments) | |
| 5772061 | VAL-MS 320/1+1 | Voltage: 320V AC; Configuration: 1+1 | Standard 1+1 protection | General single-phase ground-connected devices | |
| 2804393 | VAL-MS 320/1+1-FM | Voltage: 320V AC; Configuration: 1+1; Feature: FM (remote monitoring) | Fault status remote feedback | Critical single-phase equipment (e.g., emergency lighting power) | |
| 5772074 | VAL-MS 320/1+1-FM | Voltage: 320V AC; Configuration: 1+1; Feature: FM | Standard FM-equipped 1+1 SPD | Unattended single-phase system protection | |
| Three-Phase 3/3+0 (Three-Wire) | |||||
| 5772304 | VAL-MS 320/3 | Voltage: 320V AC; Configuration: 3-channel (three-phase) | Three-phase independent protection | Three-phase three-wire ungrounded systems (e.g., old factory motors) | |
| 2920230 | VAL-MS 320/3+0 | Voltage: 320V AC; Configuration: 3+0 (three-phase+PEN) | Three-phase shared neutral/ground | Three-phase three-wire PEN systems (e.g., compact workshop distribution) | |
| 2920243 | VAL-MS 320/3+0-FM | Voltage: 320V AC; Configuration: 3+0; Feature: FM | 3+0 configuration with remote monitoring | Critical three-phase three-wire systems (e.g., production line main drive) | |
| Three-Phase Four-Wire 3+1 | |||||
| 2859178 | VAL-MS 320/3+1 | Voltage: 320V AC; Configuration: 3+1 (three-phase+N+PE) | Three-phase four-wire basic protection | Standard industrial three-phase four-wire systems (e.g., PLC power supplies) | |
| 2858564 | VAL-MS 320 /3+1 | Voltage: 320V AC; Configuration: 3+1 | Alternative 3+1 model | General three-phase four-wire automation equipment | |
| 2859181 | VAL-MS 320/3+1/FM | Voltage: 320V AC; Configuration: 3+1; Feature: FM | 3+1 with remote fault monitoring | Unattended three-phase four-wire systems (e.g., workshop HVAC) | |
| 2858577 | VAL-MS 320 /3+1-FM | Voltage: 320V AC; Configuration: 3+1; Feature: FM | Alternative FM-equipped 3+1 SPD | Critical three-phase four-wire distribution (e.g., control cabinet main entrance) | |
| 2856689 | VAL-MS 320/3+1/FM-UD | Voltage: 320V AC; Configuration: 3+1; Feature: FM + UD | Universal wiring + remote monitoring | Mixed-terminal critical three-phase four-wire systems | |
| Three-Phase 3-FM/4-FM (Special Multi-Channel) | |||||
| 5772317 | VAL-MS 320/3-FM | Voltage: 320V AC; Configuration: 3-channel; Feature: FM | Three-channel with remote monitoring | Three-phase independent circuit critical protection | |
| 5772388 | VAL-MS 320/4-FM | Voltage: 320V AC; Configuration: 4-channel; Feature: FM | Four-channel multi-circuit protection | Multi-group three-phase/single-phase hybrid systems | |
| 5772171 | VAL-MS 320/FM | Voltage: 320V AC; Configuration: Universal; Feature: FM | Universal SPD with remote monitoring | General systems requiring fault feedback |
2. VAL-MS 275 Series (Specialized Low-Voltage Model)
Single-model with compact, quick-wiring features for 275V precision equipment.
| Part Number | Complete Model | Core Parameters | Key Functions | Application Scenario |
|---|---|---|---|---|
| 2908059 | VAL-MS 275/20 VF ST CRW | Voltage: 275V AC; Discharge Current: 20kA; Terminals: VF (fork) + ST (screw); Feature: CRW (compact width) | Quick fork-terminal wiring + space-saving design | 275V compact precision equipment (e.g., IoT edge modules, micro-sensor power) |
III. VAL-MS 320/275 Series Nomenclature Decoding
VAL-MS [Voltage]/[Configuration]-[Special Feature]
- Voltage: 320/275 → Adapted system voltage (320V for standard low-voltage, 275V for special precision systems).
- Configuration:
- 1+1 = Single-phase (L+PE, independent ground);
- 2 = Dual-channel single-phase (two independent circuits);
- 3 = Three-phase three-wire (no neutral/ground sharing);
- 3+0 = Three-phase three-wire (L1-L3+PEN, shared neutral/ground);
- 3+1 = Three-phase four-wire (L1-L3+N+PE, separate neutral/ground);
- 4 = Four-channel (multi-circuit hybrid);
- Omitted = Universal (compatible with single/three-phase basic wiring).
- Special Feature:
- FM = Remote monitoring contact (for fault status signal output);
- UD = Universal design (supports screw/spring terminal wiring);
- ST = Screw terminals (secure, anti-vibration connection);
- VF = Fork terminals (quick batch wiring, 275V model exclusive);
- CRW = Compact width (space-saving for narrow cabinets, 275V model exclusive);
- 20 = Discharge current rating (20kA, 275V model exclusive).
IV. 3-Step Quick Selection Technique
Step 1: Confirm System Voltage
- Standard 320V low-voltage industrial systems: Select VAL-MS 320 series (all models except 2908059) for general power distribution and automation equipment.
- 275V precision/special equipment: Choose VAL-MS 275/20 VF ST CRW (2908059) for compact, quick-wiring protection.
Step 2: Match Configuration to Grounding System
- Single-phase (L+N/PE):
- Independent ground (L+PE) → 1+1 configuration (e.g., 2804380 VAL-MS 320/1+1);
- Dual-circuit single-phase → 2-channel configuration (5772223 VAL-MS 320/2);
- General single-phase → Universal models (5772168 VAL-MS 320).
- Three-phase systems:
- Three-phase three-wire (PEN shared) → 3+0 configuration (2920230 VAL-MS 320/3+0);
- Three-phase three-wire (independent) → 3-channel configuration (5772304 VAL-MS 320/3);
- Three-phase four-wire (N/PE separate) → 3+1 configuration (2859178 VAL-MS 320/3+1);
- Multi-circuit hybrid → 4-channel configuration (5772388 VAL-MS 320/4-FM).
Step 3: Select Special Functions Based on Scenario
- Critical/unattended systems: Add FM suffix (e.g., 2859181 VAL-MS 320/3+1/FM) for remote fault monitoring.
- Mixed-terminal wiring: Choose UD (universal design) models (2858315 VAL-MS 320-UD ST) for screw/spring compatibility.
- Vibration-prone environments: Select ST (screw terminal) models (2838843 VAL-MS 320 ST) for secure connections.
- Batch quick-wiring (275V): Opt for VF (fork terminal) model (2908059 VAL-MS 275/20 VF ST CRW) to reduce installation time.
- Space-constrained cabinets (275V): Use CRW (compact width) model (2908059) to save 30% cabinet space.
V. Recommended Industry-Scenario Combinations
| Industry | Typical Scenario | Recommended Model Combination |
|---|---|---|
| Factory Automation (320V Three-Phase Four-Wire) | Main control cabinet entrance protection (with remote monitoring) + single-phase sensor protection | 2856689 (VAL-MS 320/3+1/FM-UD) + 2804380 (VAL-MS 320/1+1) |
| Unattended Workshop (320V Three-Phase) | Three-phase main drive (3+0) with monitoring + dual-channel actuator protection | 2920243 (VAL-MS 320/3+0-FM) + 5772223 (VAL-MS 320/2) |
| Precision Instrumentation (275V/320V Hybrid) | 275V micro-sensor quick-wiring + 320V control power protection | 2908059 (VAL-MS 275/20 VF ST CRW) + 2838843 (VAL-MS 320 ST) |
| Emergency System (320V Single-Phase) | Emergency lighting (1+1 with FM) + general indicator light protection | 5772074 (VAL-MS 320/1+1-FM) + 5772168 (VAL-MS 320) |
VI. Selection Pitfall Avoidance Guide
- Voltage mismatch: 275V precision equipment using 320V SPD → Select 2908059 VAL-MS 275/20 VF ST CRW to avoid over/undervoltage damage.
- Configuration error: Three-phase four-wire (N/PE separate) using 3+0 SPD → Choose 3+1 models (e.g., 2859178) to ensure independent neutral/ground protection.
- Monitoring function neglect: Critical unattended systems using non-FM models → Add FM suffix (e.g., 2920243) for fault early warning and remote maintenance.
- Terminal type error: Batch quick-wiring projects using ST screw terminals (320V) → For 275V systems, use VF fork terminals (2908059); for 320V, match UD universal models (2858315) for mixed wiring.
- Space constraint oversight: Narrow cabinets using standard-width SPD → Select CRW compact model (2908059) for 275V systems, or slim 320V universal models (5772168) for 320V systems.
- Grounding system mismatch: PEN-shared systems using 3+1 SPD → Opt for 3+0 models (2920230) to match the grounding architecture and avoid protection failure.
Conclusion: Select the Right VAL-MS SPD for 320V/275V System Protection
The Phoenix VAL-MS 320/275 series provides targeted overvoltage protection for low-voltage industrial systems, with diverse configurations for single-phase/three-phase circuits and flexible functions for monitoring, wiring, and space constraints.