Phoenix VAL-MS 320/275 Series Surge Protection Devices (SPD) Selection Guide

Opening: Targeted Overvoltage Protection for 320V/275V Low-Voltage Industrial Systems

The Phoenix VAL-MS 320 series is a 320V AC voltage-class surge protector (SPD) designed for industrial low-voltage power distribution, automation control, and terminal device overvoltage protection, with optional configurations (1+1/2/3/3+0/3+1/4-channel) and special functions (FM remote monitoring, UD universal design, ST screw terminals). The included VAL-MS 275/20 VF ST CRW is a 275V specialized model for compact, quick-wiring scenarios. This guide organizes part number-model correspondence, core parameters, and scenario recommendations to simplify SPD selection for different industrial systems.


I. Core Advantages of the VAL-MS 320/275 Series

  1. Wide configuration coverage: Supports single-phase (1+1), dual-channel (2), three-phase (3/3+0), and three-phase four-wire (3+1/4) systems, adapting to diverse industrial power architectures.
  2. Flexible functional extensions:
    • FM: Built-in remote monitoring contact for fault status feedback (critical for unattended systems);
    • UD: Universal design for multi-wiring compatibility (screw/spring terminals);
    • ST: Screw terminals for secure, vibration-resistant connections;
    • VF: Fork terminals for quick batch wiring (275V model exclusive).
  3. Industrial-grade reliability: IP20 protection, -40°C to +85°C operating temperature, and high surge current tolerance (20kA for 275V model), suitable for harsh factory environments.
  4. System-matched voltage: 320V for standard low-voltage industrial systems, 275V for special low-voltage equipment (e.g., precision sensors, compact control modules).

II. Complete Product Classification & Parameter Table

1. VAL-MS 320 Series (320V AC, Mainstream Configurations)

Classified by wiring configuration and special functions, covering single-phase to three-phase four-wire systems for different power and signal circuits.

Category Part Number Complete Model Core Parameters Key Functions Application Scenario
Basic Single-Phase/Dual-Channel          
  5772168 VAL-MS 320 Voltage: 320V AC; Configuration: Universal; Terminals: Standard Basic overvoltage protection General single-phase low-voltage equipment (e.g., indicator lights, small sensors)
  2838843 VAL-MS 320 ST Voltage: 320V AC; Configuration: Universal; Terminals: ST (screw) Secure screw-terminal connection Vibration-prone single-phase equipment (e.g., conveyor belt sensor power)
  2858315 VAL-MS 320-UD ST Voltage: 320V AC; Configuration: Universal; Feature: UD (universal design) + ST Multi-wiring compatibility (screw/spring) Mixed-terminal control cabinet single-phase protection
  5772223 VAL-MS 320/2 Voltage: 320V AC; Configuration: 2-channel (dual-circuit) Dual-circuit independent protection Dual-group single-phase equipment (e.g., paired actuators)
Single-Phase 1+1 (L+PE)          
  2804380 VAL-MS 320/1+1 Voltage: 320V AC; Configuration: 1+1 (L+PE) Single-phase ground-protected SPD Single-phase equipment with independent ground (e.g., laboratory precision instruments)
  5772061 VAL-MS 320/1+1 Voltage: 320V AC; Configuration: 1+1 Standard 1+1 protection General single-phase ground-connected devices
  2804393 VAL-MS 320/1+1-FM Voltage: 320V AC; Configuration: 1+1; Feature: FM (remote monitoring) Fault status remote feedback Critical single-phase equipment (e.g., emergency lighting power)
  5772074 VAL-MS 320/1+1-FM Voltage: 320V AC; Configuration: 1+1; Feature: FM Standard FM-equipped 1+1 SPD Unattended single-phase system protection
Three-Phase 3/3+0 (Three-Wire)          
  5772304 VAL-MS 320/3 Voltage: 320V AC; Configuration: 3-channel (three-phase) Three-phase independent protection Three-phase three-wire ungrounded systems (e.g., old factory motors)
  2920230 VAL-MS 320/3+0 Voltage: 320V AC; Configuration: 3+0 (three-phase+PEN) Three-phase shared neutral/ground Three-phase three-wire PEN systems (e.g., compact workshop distribution)
  2920243 VAL-MS 320/3+0-FM Voltage: 320V AC; Configuration: 3+0; Feature: FM 3+0 configuration with remote monitoring Critical three-phase three-wire systems (e.g., production line main drive)
Three-Phase Four-Wire 3+1          
  2859178 VAL-MS 320/3+1 Voltage: 320V AC; Configuration: 3+1 (three-phase+N+PE) Three-phase four-wire basic protection Standard industrial three-phase four-wire systems (e.g., PLC power supplies)
  2858564 VAL-MS 320 /3+1 Voltage: 320V AC; Configuration: 3+1 Alternative 3+1 model General three-phase four-wire automation equipment
  2859181 VAL-MS 320/3+1/FM Voltage: 320V AC; Configuration: 3+1; Feature: FM 3+1 with remote fault monitoring Unattended three-phase four-wire systems (e.g., workshop HVAC)
  2858577 VAL-MS 320 /3+1-FM Voltage: 320V AC; Configuration: 3+1; Feature: FM Alternative FM-equipped 3+1 SPD Critical three-phase four-wire distribution (e.g., control cabinet main entrance)
  2856689 VAL-MS 320/3+1/FM-UD Voltage: 320V AC; Configuration: 3+1; Feature: FM + UD Universal wiring + remote monitoring Mixed-terminal critical three-phase four-wire systems
Three-Phase 3-FM/4-FM (Special Multi-Channel)          
  5772317 VAL-MS 320/3-FM Voltage: 320V AC; Configuration: 3-channel; Feature: FM Three-channel with remote monitoring Three-phase independent circuit critical protection
  5772388 VAL-MS 320/4-FM Voltage: 320V AC; Configuration: 4-channel; Feature: FM Four-channel multi-circuit protection Multi-group three-phase/single-phase hybrid systems
  5772171 VAL-MS 320/FM Voltage: 320V AC; Configuration: Universal; Feature: FM Universal SPD with remote monitoring General systems requiring fault feedback

2. VAL-MS 275 Series (Specialized Low-Voltage Model)

Single-model with compact, quick-wiring features for 275V precision equipment.

Part Number Complete Model Core Parameters Key Functions Application Scenario
2908059 VAL-MS 275/20 VF ST CRW Voltage: 275V AC; Discharge Current: 20kA; Terminals: VF (fork) + ST (screw); Feature: CRW (compact width) Quick fork-terminal wiring + space-saving design 275V compact precision equipment (e.g., IoT edge modules, micro-sensor power)

III. VAL-MS 320/275 Series Nomenclature Decoding

VAL-MS [Voltage]/[Configuration]-[Special Feature]

  • Voltage: 320/275 → Adapted system voltage (320V for standard low-voltage, 275V for special precision systems).
  • Configuration:
    • 1+1 = Single-phase (L+PE, independent ground);
    • 2 = Dual-channel single-phase (two independent circuits);
    • 3 = Three-phase three-wire (no neutral/ground sharing);
    • 3+0 = Three-phase three-wire (L1-L3+PEN, shared neutral/ground);
    • 3+1 = Three-phase four-wire (L1-L3+N+PE, separate neutral/ground);
    • 4 = Four-channel (multi-circuit hybrid);
    • Omitted = Universal (compatible with single/three-phase basic wiring).
  • Special Feature:
    • FM = Remote monitoring contact (for fault status signal output);
    • UD = Universal design (supports screw/spring terminal wiring);
    • ST = Screw terminals (secure, anti-vibration connection);
    • VF = Fork terminals (quick batch wiring, 275V model exclusive);
    • CRW = Compact width (space-saving for narrow cabinets, 275V model exclusive);
    • 20 = Discharge current rating (20kA, 275V model exclusive).

IV. 3-Step Quick Selection Technique

Step 1: Confirm System Voltage

  • Standard 320V low-voltage industrial systems: Select VAL-MS 320 series (all models except 2908059) for general power distribution and automation equipment.
  • 275V precision/special equipment: Choose VAL-MS 275/20 VF ST CRW (2908059) for compact, quick-wiring protection.

Step 2: Match Configuration to Grounding System

  • Single-phase (L+N/PE):
    • Independent ground (L+PE) → 1+1 configuration (e.g., 2804380 VAL-MS 320/1+1);
    • Dual-circuit single-phase → 2-channel configuration (5772223 VAL-MS 320/2);
    • General single-phase → Universal models (5772168 VAL-MS 320).
  • Three-phase systems:
    • Three-phase three-wire (PEN shared) → 3+0 configuration (2920230 VAL-MS 320/3+0);
    • Three-phase three-wire (independent) → 3-channel configuration (5772304 VAL-MS 320/3);
    • Three-phase four-wire (N/PE separate) → 3+1 configuration (2859178 VAL-MS 320/3+1);
    • Multi-circuit hybrid → 4-channel configuration (5772388 VAL-MS 320/4-FM).

Step 3: Select Special Functions Based on Scenario

  • Critical/unattended systems: Add FM suffix (e.g., 2859181 VAL-MS 320/3+1/FM) for remote fault monitoring.
  • Mixed-terminal wiring: Choose UD (universal design) models (2858315 VAL-MS 320-UD ST) for screw/spring compatibility.
  • Vibration-prone environments: Select ST (screw terminal) models (2838843 VAL-MS 320 ST) for secure connections.
  • Batch quick-wiring (275V): Opt for VF (fork terminal) model (2908059 VAL-MS 275/20 VF ST CRW) to reduce installation time.
  • Space-constrained cabinets (275V): Use CRW (compact width) model (2908059) to save 30% cabinet space.

V. Recommended Industry-Scenario Combinations

Industry Typical Scenario Recommended Model Combination
Factory Automation (320V Three-Phase Four-Wire) Main control cabinet entrance protection (with remote monitoring) + single-phase sensor protection 2856689 (VAL-MS 320/3+1/FM-UD) + 2804380 (VAL-MS 320/1+1)
Unattended Workshop (320V Three-Phase) Three-phase main drive (3+0) with monitoring + dual-channel actuator protection 2920243 (VAL-MS 320/3+0-FM) + 5772223 (VAL-MS 320/2)
Precision Instrumentation (275V/320V Hybrid) 275V micro-sensor quick-wiring + 320V control power protection 2908059 (VAL-MS 275/20 VF ST CRW) + 2838843 (VAL-MS 320 ST)
Emergency System (320V Single-Phase) Emergency lighting (1+1 with FM) + general indicator light protection 5772074 (VAL-MS 320/1+1-FM) + 5772168 (VAL-MS 320)

VI. Selection Pitfall Avoidance Guide

  1. Voltage mismatch: 275V precision equipment using 320V SPD → Select 2908059 VAL-MS 275/20 VF ST CRW to avoid over/undervoltage damage.
  2. Configuration error: Three-phase four-wire (N/PE separate) using 3+0 SPD → Choose 3+1 models (e.g., 2859178) to ensure independent neutral/ground protection.
  3. Monitoring function neglect: Critical unattended systems using non-FM models → Add FM suffix (e.g., 2920243) for fault early warning and remote maintenance.
  4. Terminal type error: Batch quick-wiring projects using ST screw terminals (320V) → For 275V systems, use VF fork terminals (2908059); for 320V, match UD universal models (2858315) for mixed wiring.
  5. Space constraint oversight: Narrow cabinets using standard-width SPD → Select CRW compact model (2908059) for 275V systems, or slim 320V universal models (5772168) for 320V systems.
  6. Grounding system mismatch: PEN-shared systems using 3+1 SPD → Opt for 3+0 models (2920230) to match the grounding architecture and avoid protection failure.

Conclusion: Select the Right VAL-MS SPD for 320V/275V System Protection

The Phoenix VAL-MS 320/275 series provides targeted overvoltage protection for low-voltage industrial systems, with diverse configurations for single-phase/three-phase circuits and flexible functions for monitoring, wiring, and space constraints. 