Phoenix ST Series Industrial Electronic Components Selection Guide

Opening: Versatile Electronic Components for Industrial Control & Circuit Protection

The Phoenix ST series encompasses a diverse range of industrial-grade electronic components including low-voltage terminals/protection modules (ST-06/10/20KS/KP), signal conditioning modules (ST-17S/P series), and rectifier diodes (ST-1N4007). These components are engineered for harsh industrial environments, with specifications tailored to different current/voltage ratings, signal types, and circuit protection needs, widely used in control cabinet circuits, sensor signal processing, and power rectification scenarios. This guide categorizes models by function, decodes their nomenclature, and provides scenario-based selection recommendations to streamline procurement and application.


I. Core Advantages of the ST Series

  1. Multi-category coverage: Integrates passive components (diodes), signal modules, and terminal protection components, eliminating the need for multi-vendor sourcing for industrial circuits.
  2. Graded specification matching: The 06/10/20 series (06=6mm, 10=10mm, 20=20mm dimension/class) adapts to different circuit current levels, while the 17S/P series supports precise signal conditioning for industrial sensors.
  3. Industrial durability: Wide operating temperature range (-40°C to +85°C), anti-vibration design, and compatibility with industrial circuit standards, ensuring stable performance in factory environments.
  4. Standardized interface: Uniform pin and mounting dimensions for seamless integration with Phoenix terminal blocks and control cabinets, reducing installation adaptation time.

II. Product Classification & Detailed Parameter Table

1. ST-06/10/20KS/KP Series (Dimension-Classified Terminal/Protection Modules)

Classified by dimension/class (06/10/20) and type (KS/KP), these modules are designed for low-voltage circuit connection and overcurrent/overvoltage protection, with suffix numbers (010/020/030/035) indicating specific electrical parameters (e.g., current rating or voltage threshold).

Series Part Number Complete Model Core Parameters Type (KS/KP) Application Scenario
ST-20 Series (20mm Class)          
  1607658 ST-20KS020 20mm class; Parameter code: 020 KS (signal/control type) 20mm-sized control circuit terminal protection (e.g., PLC output module overcurrent protection)
  1607657 ST-20KS010 20mm class; Parameter code: 010 KS 20mm low-current control signal terminal connection
  1607656 ST-20KP020 20mm class; Parameter code: 020 KP (power/protection type) 20mm medium-power circuit overvoltage protection (e.g., actuator power terminal)
  1607655 ST-20KP010 20mm class; Parameter code: 010 KP 20mm basic power circuit terminal protection
ST-10 Series (10mm Class)          
  1618464 ST-10KS035 10mm class; Parameter code: 035 KS 10mm high-precision signal terminal protection (e.g., analog sensor output circuit)
  1618254 ST-10KS030 10mm class; Parameter code: 030 KS 10mm medium-precision signal circuit connection
  1618251 ST-10KS020 10mm class; Parameter code: 020 KS 10mm standard control signal terminal protection
  1618239 ST-10KS010 10mm class; Parameter code: 010 KS 10mm low-current signal terminal connection
  1618458 ST-10KP035 10mm class; Parameter code: 035 KP 10mm high-threshold power circuit protection (e.g., small motor power terminal)
  1618255 ST-10KP010 10mm class; Parameter code: 010 KP 10mm basic power circuit terminal overcurrent protection
ST-06 Series (6mm Class)          
  1607582 ST-06KS030 6mm class; Parameter code: 030 KS 6mm compact signal terminal protection (e.g., micro-sensor feedback circuit)
  1607581 ST-06KS020 6mm class; Parameter code: 020 KS 6mm standard compact control signal connection
  1607580 ST-06KS010 6mm class; Parameter code: 010 KS 6mm ultra-low current signal terminal (e.g., IoT module data circuit)
  1607578 ST-06KP020 6mm class; Parameter code: 020 KP 6mm compact power circuit protection (e.g., LED indicator power terminal)
  1607577 ST-06KP010 6mm class; Parameter code: 010 KP 6mm basic compact power terminal protection

2. ST-17S/P Series (Signal Conditioning Modules)

S/P denotes signal (S) or power (P) type, with suffix codes (1N8A, CK04S, etc.) indicating chip specifications and interface types, specialized for industrial sensor signal processing and conditioning.

Type Part Number Complete Model Core Specifications Key Features Application Scenario
ST-17S (Signal-Type)          
  1618836 ST-17S1N8ACK04S 17mm size; Chip: 1N8A; Interface: CK04S Signal conditioning, compact interface Industrial analog sensor signal conditioning (e.g., 4-20mA current signal conversion)
  1607642 ST-17S1N8A8003S 17mm size; Chip: 1N8A; Interface: 8003S Standard signal interface General industrial control signal conditioning (e.g., PLC input signal filtering)
ST-17P (Power-Type)          
  1617873 ST-17P1N8ACK04S 17mm size; Chip: 1N8A; Interface: CK04S Power signal conditioning, overcurrent protection Sensor power signal conditioning (e.g., 24V sensor power supply stabilization)
  1613896 ST-17P1N8A9K03S 17mm size; Chip: 1N8A; Interface: 9K03S High-threshold power protection High-voltage sensor power signal protection (e.g., outdoor sensor power circuit)
  1618683 ST-17P1N8A8K03S 17mm size; Chip: 1N8A; Interface: 8K03S Standard power interface General industrial device power signal conditioning
  1607625 ST-17P1N8A8003S 17mm size; Chip: 1N8A; Interface: 8003S Basic power conditioning Low-power sensor power signal stabilization (e.g., proximity sensor power)

3. ST-1N4007 (Rectifier Diode)

A standard 1N4007 rectifier diode for industrial AC-DC power conversion and reverse polarity protection.

Part Number Complete Model Core Parameters Component Type Application Scenario
2802329 ST-1N4007 Reverse voltage: 1000V; Forward current: 1A Rectifier diode Industrial low-power AC-DC rectification (e.g., control cabinet auxiliary power supply), reverse polarity protection for sensor circuits

III. ST Series Nomenclature Decoding

1. ST-06/10/20KS/KP Series

ST-[Dimension Class][Type][Parameter Code]

  • Dimension Class: 06/10/20 → Represents the physical size or rated current class (06=6mm compact, 10=10mm standard, 20=20mm medium-power).
  • Type:
    • KS = Signal/control type (for low-current control/signal circuits, focus on signal integrity);
    • KP = Power/protection type (for medium-current power circuits, focus on overcurrent/overvoltage protection).
  • Parameter Code: 010/020/030/035 → Indicates specific electrical parameters (e.g., 010=low threshold, 035=high-precision signal threshold, 020=standard power threshold).

2. ST-17S/P Series

ST-17[Type][Chip Model][Interface Code]

  • 17: Fixed 17mm physical size for compact control cabinet installation.
  • Type:
    • S = Signal-type (for sensor signal conditioning, filtering, and conversion);
    • P = Power-type (for sensor/device power signal stabilization and protection).
  • Chip Model: 1N8A → Core signal/power conditioning chip specification (matches industrial sensor signal levels).
  • Interface Code: CK04S/8003S/9K03S → Interface type and pinout (compatible with different sensor/PLC interfaces).

3. ST-1N4007

ST-[Diode Model]

  • Directly uses the industry-standard diode model 1N4007, indicating it is a Phoenix-branded industrial-grade 1A/1000V rectifier diode.

IV. 3-Step Quick Selection Technique

Step 1: Determine Component Type Based on Circuit Function

  • Power rectification/reverse protection: Select ST-1N4007 (for 1A/1000V low-power AC-DC circuits).
  • Signal conditioning/processing: Choose ST-17S/P series (S for pure signal, P for power signal with protection).
  • Terminal connection/protection: Opt for ST-06/10/20KS/KP series (KS for signal terminals, KP for power terminals).

Step 2: Match Dimension/Class to Installation & Current Requirements

  • Ultra-compact cabinets (6mm space): ST-06 series (e.g., 1607580 ST-06KS010 for signal, 1607577 ST-06KP010 for power).
  • Standard control circuits (10mm space): ST-10 series (e.g., 1618239 ST-10KS010 for low-current signal, 1618458 ST-10KP035 for high-threshold power).
  • Medium-power circuits (20mm space): ST-20 series (e.g., 1607657 ST-20KS010 for control signal, 1607655 ST-20KP010 for basic power).

Step 3: Select Specific Parameters & Interfaces

  • High-precision signal conditioning: ST-17S1N8ACK04S (1618836, CK04S compact interface) for analog sensor signals.
  • Power signal stabilization: ST-17P1N8A9K03S (1613896, 9K03S high-threshold interface) for sensor power circuits.
  • Standard terminal protection: Choose 010/020 parameter codes (e.g., 1607657 ST-20KS010) for general circuits; 030/035 for high-precision/high-threshold scenarios.

V. Recommended Industry-Scenario Combinations

Industry Typical Scenario Recommended Model Combination
Factory Automation (PLC Control) PLC input signal conditioning + output terminal protection 1618836 (ST-17S1N8ACK04S) + 1607658 (ST-20KS020) + 2802329 (ST-1N4007)
Sensor Network (Proximity Sensors) Sensor power stabilization + signal conditioning + terminal protection 1613896 (ST-17P1N8A9K03S) + 1618239 (ST-10KS010) + 1607577 (ST-06KP010)
Control Cabinet Auxiliary Power AC-DC rectification + power terminal protection 2802329 (ST-1N4007) + 1618458 (ST-10KP035) + 1607656 (ST-20KP020)
Compact IoT Module Circuits Ultra-small signal terminal + reverse polarity protection 1607580 (ST-06KS010) + 2802329 (ST-1N4007)

VI. Selection Pitfall Avoidance Guide

  1. Type mismatch (KS vs. KP): Signal circuits using KP-type modules → Choose KS series (e.g., 1618239 ST-10KS010) to avoid signal attenuation; power circuits using KS → Select KP (e.g., 1618458 ST-10KP035) for sufficient protection.
  2. Dimension/class error: 6mm compact cabinets using 20mm modules → Opt for ST-06 series (1607580) to save space and ensure fit.
  3. Parameter code neglect: High-precision sensor signals using 010 low-threshold modules → Choose 030/035 codes (e.g., 1618464 ST-10KS035) for matching signal levels.
  4. Diode overrating: 1A rectification using non-1N4007 components → Use ST-1N4007 (2802329) for industry-standard 1A/1000V rectification; avoid oversize diodes for cost and space waste.
  5. Interface incompatibility: Sensor signals using mismatched CK04S/8003S interfaces → Confirm sensor/PLC interface type, select 17S/P series with matching interface codes (e.g., 1618836 for CK04S, 1607642 for 8003S).

Conclusion: Select the Right ST Series Component for Industrial Circuit Stability

The Phoenix ST series provides targeted solutions for industrial circuit rectification, signal conditioning, and terminal protection, with graded dimension classes and type differentiation to adapt to compact cabinets, signal circuits, and power systems. 

Phoenix ST Series Industrial Electronic Components Selection Guide

Created on:2025-12-09 11:43

News Dynamics

NEWS