Phoenix RIF Series Industrial Interface Relays & Protective Modules Selection Guide

Opening: Versatile Interface Relays for Industrial Control Circuit Protection & Signal Conversion

The Phoenix RIF series encompasses a full range of industrial-grade interface relays and protective modules, including voltage-specific interface units (RIF-V/RIF-RC/RIF-LV), surge-protected modules (RIF-LDP), multi-channel relay interfaces (RIF-4-RSC/RIF-4-RPT), and specialized protective units (RIF-RPT-LDP). These components support diverse control voltages (12-230V AC/DC), flexible contact configurations (1X2/2X21/3X1/3X21), and core functions like inductive load surge protection (LDP), low-voltage compatibility (LV), and enhanced contact capacity (AU). Widely used in factory automation, power distribution, and critical control circuits, they bridge control signals and load circuits while ensuring stable operation in harsh industrial environments. This guide categorizes models by function, decodes nomenclature, and provides scenario-based recommendations for efficient selection.


I. Core Advantages of the RIF Series

  1. Wide voltage compatibility: Covers 12-24V DC, 48-60V DC, 110V DC, 120-230V AC, adapting to global industrial control system voltage standards.
  2. Diverse contact configurations: Supports single-pole double-throw (1X2), double-pole changeover (2X21), triple-pole normally open (3X1), and triple-pole changeover (3X21) contacts, matching different load circuit needs.
  3. Targeted protective functions: LDP (surge protection for inductive loads like motors/solenoids) prevents voltage spikes from damaging devices; AU (enhanced contacts) boosts load-bearing capacity for critical circuits.
  4. Modular multi-channel design: The RIF-4 series (4-channel) realizes centralized control of multiple loads, reducing cabinet wiring complexity and improving system integration.
  5. Industrial durability: -40°C to +85°C operating temperature, anti-vibration construction, and IP20 protection (cabinet-mounted), ensuring reliability in factory floor and outdoor auxiliary control scenarios.

II. Product Classification & Detailed Parameter Table

1. Voltage-Specific Interface Units (RIF-V/RIF-T3/RIF-RC/RIF-LV)

Designed for direct voltage matching with control systems, featuring compact structures for basic signal-to-load interface conversion without complex protective functions.

Sub-series Part Number Complete Model Core Parameters Key Features Application Scenario
RIF-V Series          
  2900945 RIF-V-12-24UC Control Voltage: 12-24V DC/AC (UC=universal current) Low-voltage universal interface 12-24V DC/AC small-signal control circuit interface (e.g., sensor to micro-actuator)
  2900948 RIF-V-120-230UC Control Voltage: 120-230V AC (universal) Mains-voltage universal interface 120-230V AC industrial mains control circuit interface (e.g., lighting/ventilation control)
RIF-T3 Series          
  2902647 RIF-T3-24UC Control Voltage: 24V DC/AC; Type: T3 (triple-channel basic interface) 24V triple-channel compact interface 24V DC/AC triple-channel low-power load control (e.g., three-group indicator lights)
RIF-RC Series          
  2900949 RIF-RC-12-24 UC Control Voltage: 12-24V DC/AC; Type: RC (relay contact interface) 12-24V relay contact-type interface 12-24V DC/AC control circuit to relay load interface (e.g., small solenoid valve control)
  2900951 RIF-RC-120-230UC Control Voltage: 120-230V AC; Type: RC Mains-voltage relay contact interface 120-230V AC mains to medium-power relay load interface (e.g., workshop exhaust fan control)
RIF-LV Series (Low-Voltage)          
  2900944 RIF-LV-120-230 AC/110 DC Control Voltage: 120-230V AC/110V DC; Type: LV (low-voltage compatible) Cross-voltage low-voltage interface Mixed-voltage control systems (120-230V AC/110V DC) to low-power load interface (e.g., legacy equipment control)

2. Surge-Protected Modules (RIF-LDP)

Specialized in surge suppression for inductive loads, preventing voltage spikes from inductive device shutdowns from damaging control circuits.

Part Number Complete Model Core Parameters Key Function Application Scenario
2900940 RIF-LDP-48-60 DC Control Voltage: 48-60V DC; Feature: LDP (inductive load surge protection) 48-60V DC inductive load surge suppression 48-60V DC medium-voltage inductive load control (e.g., DC motor auxiliary circuit protection)
2900939 RIF-LDP-12-24 DC Control Voltage: 12-24V DC; Feature: LDP 12-24V DC inductive load surge suppression 12-24V DC low-voltage inductive load control (e.g., small solenoid valve, stepper motor driver protection)

3. Specialized Multi-Contact Protective Units (RIF-RPT-LDP)

Integrate LDP surge protection and AU enhanced contacts, with mixed contact configurations for complex control circuits requiring both protection and high load capacity.

Part Number Complete Model Core Parameters Key Features Application Scenario
1148699 RIF-RPT-LDP-24DC/2X2/2X1/AU/FG Control Voltage: 24V DC; Contacts: 2X2 (2xSPDT) + 2X1 (2xNO); Features: LDP + AU (enhanced contacts) + FG (functional ground) Dual SPDT + dual NO, surge protection + enhanced contacts 24V DC critical inductive load control (e.g., robotic arm joint actuator with feedback)
1148703 RIF-RPT-LDP-24DC/1X2/3X1/AU/FG Control Voltage: 24V DC; Contacts: 1X2 (1xSPDT) + 3X1 (3xNO); Features: LDP + AU + FG Single SPDT + triple NO, surge protection 24V DC mixed load control (1 group of feedback + 3 groups of power output, e.g., packaging machine actuator control)

4. RIF-4 Series (4-Channel Multi-Interface Relays)

4-channel centralized control modules, categorized by interface type (RSC/RPT/BSC/BPT) and function (LV low-voltage/LDP surge protection), supporting 120-230V AC and 24V DC control voltages.

Sub-series Part Number Complete Model Core Parameters Key Features Application Scenario
RIF-4-RSC (RSC Interface)          
  2903285 RIF-4-RSC-LV-230AC/3X21 Control Voltage: 230V AC (LV); Contacts: 3X21 (3xchangeover); Interface: RSC 230V AC, 3xchangeover contacts 230V AC three-group changeover load control (e.g., production line conveyor belt forward/reverse/stop)
  2903282 RIF-4-RSC-LV-230AC/3X1 Control Voltage: 230V AC (LV); Contacts: 3X1 (3xNO); Interface: RSC 230V AC, 3xNO contacts 230V AC three-group normally open load control (e.g., workshop three-group lighting)
  2903287 RIF-4-RSC-LV-120AC/3X21 Control Voltage: 120V AC (LV); Contacts: 3X21; Interface: RSC 120V AC, 3xchangeover contacts North American 120V AC three-group changeover load control (e.g., local equipment forward/reverse control)
  2903283 RIF-4-RSC-LV-120AC/3X1 Control Voltage: 120V AC (LV); Contacts: 3X1; Interface: RSC 120V AC, 3xNO contacts North American 120V AC three-group NO load control (e.g., local ventilation fan groups)
  2903288 RIF-4-RSC-LDP-24DC/3X21 Control Voltage: 24V DC (LDP); Contacts: 3X21; Interface: RSC 24V DC, surge protection, 3xchangeover 24V DC inductive load three-group changeover control (e.g., three-group solenoid valve with surge protection)
  2903284 RIF-4-RSC-LDP-24DC/3X1 Control Voltage: 24V DC (LDP); Contacts: 3X1; Interface: RSC 24V DC, surge protection, 3xNO 24V DC inductive load three-group NO control (e.g., three-group small motor power supply)
RIF-4-RPT (RPT Interface)          
  2903276 RIF-4-RPT-LV-230AC/3X21 Control Voltage: 230V AC (LV); Contacts: 3X21; Interface: RPT 230V AC, 3xchangeover, RPT interface 230V AC precision three-group changeover control (e.g., pharmaceutical equipment process control)
  2903273 RIF-4-RPT-LV-230AC/3X1 Control Voltage: 230V AC (LV); Contacts: 3X1; Interface: RPT 230V AC, 3xNO, RPT interface 230V AC precision three-group NO control (e.g., food packaging machine heating control)
  2903279 RIF-4-RPT-LV-230AC/2X21 Control Voltage: 230V AC (LV); Contacts: 2X21; Interface: RPT 230V AC, 2xchangeover, RPT interface 230V AC two-group changeover precision control (e.g., labeling machine position switching)
  2903277 RIF-4-RPT-LV-120AC/3X21 Control Voltage: 120V AC (LV); Contacts: 3X21; Interface: RPT 120V AC, 3xchangeover, RPT interface North American 120V AC precision three-group changeover control (e.g., local medical equipment auxiliary control)
  2903274 RIF-4-RPT-LV-120AC/3X1 Control Voltage: 120V AC (LV); Contacts: 3X1; Interface: RPT 120V AC, 3xNO, RPT interface North American 120V AC precision three-group NO control (e.g., local laboratory equipment heating)
  2903280 RIF-4-RPT-LV-120AC/2X21 Control Voltage: 120V AC (LV); Contacts: 2X21; Interface: RPT 120V AC, 2xchangeover, RPT interface North American 120V AC two-group changeover precision control (e.g., small printing machine mode switching)
  2903278 RIF-4-RPT-LDP-24DC/3X21 Control Voltage: 24V DC (LDP); Contacts: 3X21; Interface: RPT 24V DC, surge protection, 3xchangeover 24V DC precision inductive load three-group changeover control (e.g., robotic gripper position switching)
  2903275 RIF-4-RPT-LDP-24DC/3X1 Control Voltage: 24V DC (LDP); Contacts: 3X1; Interface: RPT 24V DC, surge protection, 3xNO 24V DC precision inductive load three-group NO control (e.g., automated test fixture actuator control)
  2903281 RIF-4-RPT-LDP-24DC/2X21 Control Voltage: 24V DC (LDP); Contacts: 2X21; Interface: RPT 24V DC, surge protection, 2xchangeover 24V DC precision inductive load two-group changeover control (e.g., sorting machine channel switching)
RIF-4-BSC/BPT (Basic Interface)          
  2900960 RIF-4-BSC/3X21 Control Voltage: Universal; Interface: BSC (basic); Contacts: 3X21 Basic 3xchangeover interface General-purpose three-group changeover load control (e.g., non-critical workshop equipment)
  2900961 RIF-4-BPT/3X21 Control Voltage: Universal; Interface: BPT (basic); Contacts: 3X21 Basic RPT-type 3xchangeover interface General-purpose precision three-group changeover control (e.g., assembly line auxiliary equipment)

III. RIF Series Nomenclature Decoding

RIF-[Sub-series/Function]-[Voltage]-[Contact Configuration]-[Special Features]

  • Sub-series/Function:
    • V = Voltage-universal interface unit;
    • T3 = Triple-channel basic interface;
    • RC = Relay contact-type interface;
    • LV = Low-voltage compatible interface;
    • LDP = Inductive load surge protection module;
    • RPT/RSC = Specialized multi-channel interface (RPT for precision control, RSC for standard control);
    • BSC/BPT = Basic multi-channel interface (BSC standard, BPT precision).
  • Voltage:
    • 12-24UC = 12-24V AC/DC universal;
    • 120-230UC = 120-230V AC universal;
    • 48-60DC = 48-60V DC;
    • 230AC/120AC = Mains voltage (Europe/North America);
    • 24DC = 24V DC (industrial automation standard).
  • Contact Configuration:
    • 1X2 = 1 group of single-pole double-throw (SPDT) contacts;
    • 2X21 = 2 groups of changeover contacts (1NO+1NC per group);
    • 3X1 = 3 groups of normally open (NO) contacts;
    • 3X21 = 3 groups of changeover contacts;
    • 2X2/2X1 = Mixed (2SPDT + 2NO) contacts.
  • Special Features:
    • AU = Enhanced load-bearing contacts (for high-current/critical loads);
    • FG = Functional ground (improves anti-interference for sensitive circuits);
    • UC = Universal current (compatible with AC/DC control voltages).

IV. 3-Step Quick Selection Technique

Step 1: Confirm Control Voltage Compatibility

  • Low-voltage automation systems (12-24V DC/AC): Select RIF-V-12-24UC (2900945), RIF-LDP-12-24DC (2900939), or RIF-4-RPT-LDP-24DC series (e.g., 2903278) for surge protection.
  • Mains voltage (230V AC, Europe/Asia): Choose RIF-V-120-230UC (2900948), RIF-4-RSC-LV-230AC series (e.g., 2903285), or RIF-4-RPT-LV-230AC series (e.g., 2903276).
  • North American mains (120V AC): Opt for RIF-4-RSC-LV-120AC series (2903287) or RIF-4-RPT-LV-120AC series (2903277).
  • Mixed voltage (120-230V AC/110V DC): Select RIF-LV-120-230 AC/110 DC (2900944) for legacy system compatibility.
  • Medium-voltage DC (48-60V DC): Use RIF-LDP-48-60 DC (2900940) for inductive load protection.

Step 2: Match Contact Configuration to Load Type

  • Single/mixed load control (feedback + power): Choose mixed-contact models (e.g., 1148699 RIF-RPT-LDP-24DC/2X2/2X1/AU/FG) for dual SPDT feedback + dual NO power output.
  • Changeover load (forward/reverse/stop): Select 2X21/3X21 contact models (e.g., 2903285 RIF-4-RSC-LV-230AC/3X21, 2903278 RIF-4-RPT-LDP-24DC/3X21).
  • Simple normally open load (lighting/ventilation): Pick 3X1 contact models (e.g., 2903282 RIF-4-RSC-LV-230AC/3X1, 2903273 RIF-4-RPT-LV-230AC/3X1).

Step 3: Select Special Functions Based on Circuit Requirements

  • Inductive loads (motors/solenoids): Add LDP suffix (e.g., 2900939, 2903278) to suppress voltage spikes and extend device life.
  • Critical high-load circuits: Choose models with AU enhanced contacts (e.g., 1148699, 1148703) for improved load capacity and reliability.
  • Sensitive control circuits: Select models with FG functional ground (e.g., 1148699) to reduce electromagnetic interference.
  • Centralized multi-channel control: Opt for the RIF-4 series (4-channel, e.g., 2903285, 2903276) to simplify cabinet wiring and realize batch load control.

V. Recommended Industry-Scenario Combinations

Industry Typical Scenario Recommended Model Combination
Automotive Manufacturing (Robotic Workstations) 24V DC robotic gripper position switching (inductive load + changeover control) 2903278 (RIF-4-RPT-LDP-24DC/3X21) + 1148699 (RIF-RPT-LDP-24DC/2X2/2X1/AU/FG)
Pharmaceutical Processing (Precision Control) 230V AC three-group process changeover control (clean room equipment) 2903276 (RIF-4-RPT-LV-230AC/3X21) + 2900948 (RIF-V-120-230UC)
North American Industrial Equipment (120V AC) 120V AC three-group ventilation fan control (local factory) 2903287 (RIF-4-RSC-LV-120AC/3X21) + 2903274 (RIF-4-RPT-LV-120AC/3X1)
Legacy System Upgrade (Mixed Voltage) 120-230V AC/110V DC auxiliary equipment control (old workshop) 2900944 (RIF-LV-120-230 AC/110 DC) + 2900960 (RIF-4-BSC/3X21)
Packaging Machine (Inductive Load Control) 24V DC three-group solenoid valve control (with surge protection) 2900939 (RIF-LDP-12-24 DC) + 2903284 (RIF-4-RSC-LDP-24DC/3X1)

VI. Selection Pitfall Avoidance Guide

  1. Voltage mismatch: 24V DC inductive loads using 230V AC modules → Select LDP suffix 24V DC models (e.g., 2900939, 2903278) to prevent module burnout and load damage.
  2. Inductive load protection neglect: Motors/solenoids using non-LDP modules → Add LDP function (e.g., 2903288) to suppress voltage spikes and avoid control circuit failure.
  3. Contact configuration error: Changeover load (forward/reverse) using NO-only contacts → Choose 2X21/3X21 changeover models (e.g., 2903285) to realize bidirectional control.
  4. Critical load contact capacity insufficient: High-current critical circuits using standard contacts → Select AU-enhanced contact models (e.g., 1148699) to ensure load-bearing stability.
  5. Multi-channel control using single-channel modules: 4-channel load control using multiple single-channel units → Opt for RIF-4 series (e.g., 2903276) to reduce cabinet space and wiring complexity.
  6. Mixed voltage system using single-voltage modules: 120-230V AC/110V DC legacy systems using 24V modules → Use RIF-LV-120-230 AC/110 DC (2900944) for cross-voltage compatibility.

Conclusion: Select the Right RIF Series Component for Industrial Control Circuit Stability

The Phoenix RIF series provides targeted interface relay and protective module solutions for industrial control circuits, covering diverse voltage ranges, contact configurations, and core functions like surge protection and enhanced load capacity. 

Phoenix RIF Series Industrial Interface Relays & Protective Modules Selection Guide

Created on:2025-12-10 13:29

News Dynamics

NEWS