Phoenix REL-MR/REL-MR-BL Series Industrial Interface Relays Selection Guide
Opening: Compact Plug-in Relays for Industrial Control Circuit Signal Conversion & Load Driving
The Phoenix REL-MR/REL-MR-BL series is a portfolio of high-reliability plug-in industrial interface relays, covering control voltages from 12DC to 230AC, with contact configurations of 21HC (single changeover) and 21-21 (dual changeover), and optional special functions like MS (test button + mechanical indicator), AU (enhanced contacts), and ATEX (explosion-proof certification). Widely used in PLC control systems, solenoid valve driving, and hazardous area equipment control, these relays feature plug-in installation for quick maintenance, high switching capacity (up to 16A), and a wide operating temperature range (-40°C to +85°C), ensuring stable performance in harsh industrial environments. This guide categorizes models by function, decodes nomenclature, and provides scenario-based recommendations for efficient selection.
I. Core Advantages of the REL-MR/REL-MR-BL Series
- Wide voltage compatibility: Supports 12DC/18DC/24DC/60DC/110DC/24AC/120AC/230AC control voltages, adapting to global industrial control system standards.
- Flexible contact configurations: 21HC (1NO+1NC single changeover) and 21-21 (2NO+2NC dual independent changeover) meet single/dual load control needs, with a maximum switching current of 16A for heavy-load driving.
- Diversified special functions:
- MS: Built-in test button and mechanical position indicator for convenient maintenance and fault diagnosis;
- AU: Enhanced contact material for extended electrical life and higher load-bearing capacity (suitable for frequent switching);
- ATEX: Explosion-proof certification for equipment control in hazardous areas (e.g., chemical plants, oil and gas fields).
- Plug-in design: Enables tool-free quick replacement, reducing equipment downtime by 60% compared to soldered relays.
- Industrial durability: 10 million mechanical operation cycles, IP20 protection (cabinet-mounted), and anti-vibration construction for factory floor and outdoor auxiliary control scenarios.
II. Product Classification & Detailed Parameter Table
1. REL-MR-BL Sub-series (Blue-Housed Specialized Relays)
With blue housing for visual circuit differentiation, suitable for critical control circuits requiring clear identification.
| Category | Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|---|
| 24V DC Control | |||||
| 2908180 | REL-MR-BL-24DC/21HC/MS | Control Voltage: 24DC; Contact: 21HC (1NO+1NC); Feature: MS | Test button + mechanical indicator, single changeover | 24V DC critical control circuits (e.g., PLC output to emergency solenoid valve, with maintenance test function) | |
| 2908181 | REL-MR-BL-24DC/21-21/MS | Control Voltage: 24DC; Contact: 21-21 (2NO+2NC); Feature: MS | Test button, dual changeover | 24V DC dual-load independent control (e.g., robotic arm clamp + release actuator) | |
| 2906285 | REL-MR-BL-24DC/21HC | Control Voltage: 24DC; Contact: 21HC | Standard single changeover | General 24V DC control circuits (e.g., sensor signal to small motor) | |
| 2906286 | REL-MR-BL-24DC/21-21 | Control Voltage: 24DC; Contact: 21-21 | Standard dual changeover | 24V DC dual-group load control (e.g., conveyor belt start + stop) | |
| 24V AC Control | |||||
| 1109540 | REL-MR-BL-24AC/21HC | Control Voltage: 24AC; Contact: 21HC | Standard single changeover | 24V AC control systems (e.g., legacy equipment with AC sensor feedback) | |
| 1109546 | REL-MR-BL-24AC/21-21 | Control Voltage: 24AC; Contact: 21-21 | Standard dual changeover | 24V AC dual-load control (e.g., AC solenoid valve + indicator light) | |
| 230V AC Control | |||||
| 2906288 | REL-MR-BL-230AC/21HC | Control Voltage: 230AC; Contact: 21HC | Standard single changeover | 230V AC mains control circuits (e.g., workshop lighting group control) | |
| 2906287 | REL-MR-BL-230AC/21-21 | Control Voltage: 230AC; Contact: 21-21 | Standard dual changeover | 230V AC dual-group load control (e.g., exhaust fan + cooling water pump) |
2. REL-MR Sub-series (Standard General-Purpose Relays)
Covers more voltage types and special functions, suitable for general industrial control and customized scenarios.
| Voltage Type | Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|---|
| 24V DC | |||||
| 2987888 | REL-MR-24DC/21HC/MS | 24DC; 21HC; MS | Test button + mechanical indicator | 24V DC control circuits requiring maintenance convenience (e.g., production line I/O module) | |
| 2961545 | REL-MR-24DC/21HC AU | 24DC; 21HC; AU | Enhanced contacts (high load/frequent switching) | 24V DC high-cycle control (e.g., packaging machine actuator with 10k+ daily operations) | |
| 2906213 | REL-MR-24DC/21-21/ATEX | 24DC; 21-21; ATEX | Explosion-proof certification | 24V DC hazardous area control (e.g., chemical plant solenoid valve) | |
| 230V AC | |||||
| 2987914 | REL-MR-230AC/21HC/MS | 230AC; 21HC; MS | Test button + indicator | 230V AC mains circuits with maintenance needs (e.g., factory ventilation control) | |
| 2961529 | REL-MR-230AC/21HC AU | 230AC; 21HC; AU | Enhanced contacts | 230V AC high-load control (e.g., large power contactor coil driving) | |
| 2961422 | REL-MR-230AC/21HC | 230AC; 21HC | Standard type | General 230V AC single-load control | |
| 2987998 | REL-MR-230AC/21-21AU/MS | 230AC; 21-21; AU+MS | Enhanced contacts + test button | 230V AC critical dual-load control (e.g., emergency shutdown + backup system) | |
| 2961480 | REL-MR-230AC/21-21AU | 230AC; 21-21; AU | Enhanced dual changeover | 230V AC high-cycle dual-load control | |
| 2987972 | REL-MR-230AC/21-21/MS | 230AC; 21-21; MS | Test button for dual load | 230V AC dual-load circuits with maintenance needs | |
| 2961451 | REL-MR-230AC/21-21 | 230AC; 21-21 | Standard dual changeover | General 230V AC dual-load control | |
| 120V AC | |||||
| 2987901 | REL-MR-120AC/21HC/MS | 120AC; 21HC; MS | Test button + indicator | North American 120V AC control (e.g., local workshop equipment) | |
| 2961419 | REL-MR-120AC/21HC | 120AC; 21HC | Standard type | General 120V AC single-load control | |
| 2961477 | REL-MR-120AC/21-21AU | 120AC; 21-21; AU | Enhanced dual changeover | 120V AC high-cycle dual-load control | |
| 2987969 | REL-MR-120AC/21-21/MS | 120AC; 21-21; MS | Test button for dual load | 120V AC dual-load circuits with maintenance needs | |
| 2961448 | REL-MR-120AC/21-21 | 120AC; 21-21 | Standard dual changeover | General 120V AC dual-load control | |
| 110V DC | |||||
| 2961561 | REL-MR-110DC/21HC AU | 110DC; 21HC; AU | Enhanced single changeover | 110V DC high-load control (e.g., legacy DC motor control) | |
| 2961338 | REL-MR-110DC/21HC | 110DC; 21HC | Standard type | General 110V DC single-load control | |
| 2961228 | REL-MR-110DC/21-21AU | 110DC; 21-21; AU | Enhanced dual changeover | 110V DC high-cycle dual-load control | |
| 2961202 | REL-MR-110DC/21-21 | 110DC; 21-21 | Standard dual changeover | General 110V DC dual-load control | |
| 60V DC | |||||
| 2961134 | REL-MR-60DC/21AU | 60DC; 21 (single NO); AU | Enhanced single normally open | 60V DC high-load single-circuit control (e.g., medium-voltage solenoid valve) | |
| 2961273 | REL-MR-60DC/21-21 | 60DC; 21-21 | Standard dual changeover | 60V DC dual-load control (e.g., custom equipment actuator) | |
| 2909643 | REL-MR-60DC/21/MS | 60DC; 21; MS | Test button for single NO | 60V DC circuits with maintenance needs | |
| 2961118 | REL-MR-60DC/21 | 60DC; 21 | Standard single NO | General 60V DC single-load control | |
| 18V DC | |||||
| 2961383 | REL-MR-18DC/21 | 18DC; 21 | Standard single NO | 18V DC low-voltage control (e.g., micro-sensor actuator) |
III. REL-MR/REL-MR-BL Series Nomenclature Decoding
REL-MR[-BL]-[Control Voltage]/[Contact Configuration]-[Special Features]
- REL-MR[-BL]:
- REL-MR = Standard general-purpose interface relay;
- REL-MR-BL = Blue-housed specialized relay (for critical circuit identification).
- Control Voltage:
- 24DC/24AC = 24V DC/AC (industrial automation standard voltage);
- 120AC/230AC = Mains voltage (120V for North America, 230V for Europe/Asia);
- 18DC/60DC/110DC = Special DC voltages (for legacy/custom systems).
- Contact Configuration:
- 21 = Single normally open (NO) contact (1-pole, 1NO);
- 21HC = Single changeover contact (1NO+1NC, 1-pole double-throw);
- 21-21 = Dual independent changeover contacts (2NO+2NC, two 21HC groups).
- Special Features:
- MS = Test button + mechanical position indicator (maintenance-friendly);
- AU = Enhanced contact material (higher load capacity, longer electrical life for frequent switching);
- ATEX = Explosion-proof certification (for Zone 2/Ex I Div. 2 hazardous areas);
- Omitted = Standard model (no special functions, cost-effective for general scenarios).
IV. 3-Step Quick Selection Technique
Step 1: Confirm Control Voltage Matching the System
- 24V DC PLC control systems: Choose 24DC models (e.g., 2908180 REL-MR-BL-24DC/21HC/MS, 2987888 REL-MR-24DC/21HC/MS) for direct compatibility with PLC outputs.
- 230V AC mains control: Select 230AC models (e.g., 2906288 REL-MR-BL-230AC/21HC, 2987914 REL-MR-230AC/21HC/MS) for workshop lighting/pump control.
- North American 120V AC systems: Opt for 120AC models (e.g., 2987901 REL-MR-120AC/21HC/MS, 2961419 REL-MR-120AC/21HC).
- Special voltage systems (18DC/60DC/110DC): Pick corresponding voltage models (e.g., 2961383 18DC, 2961118 60DC, 2961338 110DC) for legacy/custom equipment.
Step 2: Select Contact Configuration Based on Load Quantity/Type
- Single load control (with feedback): Use 21HC (1NO+1NC) models (e.g., 2906285 REL-MR-BL-24DC/21HC) to realize load driving + status feedback.
- Dual independent load control: Choose 21-21 (2NO+2NC) models (e.g., 2906286 REL-MR-BL-24DC/21-21, 2961451 REL-MR-230AC/21-21) for two separate circuits.
- Simple single-load on/off: Select 21 (single NO) models (e.g., 2961118 REL-MR-60DC/21, 2961383 REL-MR-18DC/21) for cost-effectiveness.
Step 3: Add Special Functions According to Scenario Requirements
- Maintenance-intensive circuits: Add MS (test button + indicator) (e.g., 2908180, 2987888) to simplify fault diagnosis and regular testing.
- High-cycle/frequent switching scenarios: Select AU enhanced contacts (e.g., 2961545, 2961529) to extend relay life by 2-3 times compared to standard models.
- Hazardous areas (chemical/oil&gas): Choose ATEX certified models (e.g., 2906213) to meet explosion-proof safety standards.
- Critical circuit identification: Use REL-MR-BL blue-housed models (e.g., 2906285, 2906288) for visual differentiation from general circuits.
V. Recommended Industry-Scenario Combinations
| Industry | Typical Scenario | Recommended Model Combination |
|---|---|---|
| Automotive Manufacturing (Robotic Workstations) | 24V DC robotic gripper control (critical, with maintenance needs) + dual actuator driving | 2908180 (REL-MR-BL-24DC/21HC/MS) + 2908181 (REL-MR-BL-24DC/21-21/MS) |
| Chemical Industry (Hazardous Areas) | 24V DC solenoid valve control (explosion-proof) + 230V AC ventilation backup | 2906213 (REL-MR-24DC/21-21/ATEX) + 2961422 (REL-MR-230AC/21HC) |
| North American Machinery (120V AC) | 120V AC equipment main control (with maintenance) + dual auxiliary load | 2987901 (REL-MR-120AC/21HC/MS) + 2987969 (REL-MR-120AC/21-21/MS) |
| Packaging Industry (High-Cycle Control) | 24V DC high-frequency actuator (enhanced contacts) + 230V AC heating control | 2961545 (REL-MR-24DC/21HC AU) + 2961529 (REL-MR-230AC/21HC AU) |
| Legacy System Upgrade (60V DC) | 60V DC custom equipment single-load control (with test function) + dual backup | 2909643 (REL-MR-60DC/21/MS) + 2961273 (REL-MR-60DC/21-21) |
VI. Selection Pitfall Avoidance Guide
- Voltage mismatch: 24V DC PLC outputs using 230V AC relays → Confirm system control voltage, select matching 24DC models (e.g., 2908180) to prevent relay burnout and control failure.
- Contact configuration error: Dual-load control using single-changeover (21HC) relays → Choose 21-21 dual-changeover models (e.g., 2906286) to avoid circuit multiplexing and signal interference.
- Special function neglect: High-cycle control using standard contacts → Add AU enhanced contacts (e.g., 2961545) to prevent contact ablation and frequent replacement.
- Hazardous area non-compliance: Explosive environments using non-ATEX models → Select ATEX-certified relays (e.g., 2906213) to meet safety regulations and avoid operational risks.
- Maintenance convenience oversight: Hard-to-access circuits using non-MS models → Equip with MS test buttons (e.g., 2987888) to reduce maintenance downtime and diagnostic difficulty.
- Circuit identification confusion: Critical circuits using standard (non-BL) relays → Use REL-MR-BL blue-housed models (e.g., 2906285) for visual differentiation and quick fault location.
Conclusion: Select the Right REL-MR Relay for Industrial Control Stability