Phoenix FB Series Industrial Bus & Interface Modules Selection Guide
Opening: Modular Bus & Interface Solutions for Industrial Communication & Signal Distribution
The Phoenix FB series is a versatile portfolio of industrial bus communication modules, interface slot units, and diagnostic components designed for factory automation systems. Covering PROFIBUS (DP/PA) bus expansion, Ethernet communication, signal slot distribution, and system diagnostic functions, these modules feature modular design, industrial-grade durability (-40°C to +75°C operating range), and compatibility with Phoenix control cabinet infrastructure. Widely used in PROFIBUS network extension, distributed I/O slot management, and industrial system fault diagnosis, they ensure seamless data transmission and flexible interface expansion in harsh industrial environments.
I. Core Advantages of the FB Series
- Multi-bus compatibility: Supports PROFIBUS DP/PA, Ethernet, and fieldbus (FF) protocols, enabling interconnection between heterogeneous industrial networks and field devices.
- Modular slot flexibility: Offers slot units (2SP/4SP/6SP/8SP/12SP) with optional isolation (ISO) for signal/device segmentation, adapting to small-to-large-scale I/O and interface expansion needs.
- Specialized bus extension: PROFIBUS repeaters (FB-DP-RPTR) and high-speed bus modules (FB-HSB/HSB-DP) extend bus transmission distance and enhance signal integrity for long-distance networks.
- Integrated diagnostic functions: FB-DIAG series modules provide FF fieldbus fault diagnosis (LI/NC) for quick fault localization and system maintenance.
- Industrial reliability: IP20 cabinet protection, anti-vibration (5g) design, and 4kV surge immunity, ensuring stable operation in factory floors and remote industrial sites.
II. Product Classification & Detailed Parameter Table
The FB series is categorized by core function: high-speed bus modules (FB-Hx), Ethernet modules (FB-ET), PROFIBUS repeaters (FB-DP-RPTR), diagnostic modules (FB-DIAG), slot interface modules (FB-xSP), and next-gen slot modules (FB1/FB2).
1. FB-Hx Series (High-Speed Bus & Power Modules)
Specialized for high-speed bus communication and power supply, supporting PROFIBUS DP/PA and high-current power distribution for industrial devices.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 2316383 | FB-HSP-PLUG/24DC/6A | Power: 24V DC, 6A; Type: High-speed power plug module | 24V DC 6A high-current power supply for high-speed bus devices | Power supply for high-speed PROFIBUS/Ethernet bus modules (e.g., core network power redundancy) |
| 2316371 | FB-HSC | Type: High-speed bus communication controller | Centralized control of high-speed bus networks, signal synchronization | High-speed bus master controller for factory-level real-time data transmission |
| 2316381 | FB-HSB-DP-SC/PA | Bus: PROFIBUS DP/PA; Fiber: SC single-mode; Feature: PA bus support | DP/PA hybrid bus + SC fiber, long-distance PA device connection | Cross-workshop PROFIBUS DP/PA hybrid network (e.g., connecting PA field instruments via SC fiber) |
| 2316382 | FB-HSB-DP-SC | Bus: PROFIBUS DP; Fiber: SC single-mode | DP bus + SC fiber, anti-interference long-distance transmission | Remote workshop PROFIBUS DP network (e.g., outdoor DP sensor data collection via SC fiber) |
| 2316370 | FB-HSB-DP/PA | Bus: PROFIBUS DP/PA; No fiber interface | DP/PA hybrid bus, field instrument integration | Workshop-level PROFIBUS DP/PA network (e.g., connecting DP controllers and PA pressure/temperature instruments) |
| 2316379 | FB-HSB | Type: Basic high-speed bus module | Standard high-speed bus communication, no protocol-specific suffix | General high-speed bus device connection (e.g., auxiliary workshop bus data transmission) |
| 2316372 | FB-HSA | Type: High-speed bus adapter | Bus protocol conversion (e.g., high-speed bus to legacy fieldbus) | Legacy fieldbus device integration into high-speed industrial networks (e.g., old analog sensors to digital bus) |
2. FB-ET Series (Ethernet Communication Modules)
Ethernet interface modules for connecting PROFIBUS/fieldbus systems to Ethernet networks, realizing industrial network IP-based interconnection.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 2316050 | FB-ET/E | Ethernet: Enhanced (E-type); Interface: Industrial Ethernet | Enhanced anti-interference Ethernet communication, wide-temperature support | Harsh-environment Ethernet bus connection (e.g., outdoor Ethernet-to-fieldbus gateway) |
| 2316048 | FB-ET | Ethernet: Standard industrial grade | Basic Ethernet-to-fieldbus data exchange | General workshop Ethernet/fieldbus interconnection (e.g., PLC Ethernet communication with field sensors) |
3. FB-DP-RPTR Series (PROFIBUS DP Repeaters)
Extend PROFIBUS DP bus transmission distance and increase node count, with optional SC fiber interface for long-distance networks.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 2316374 | FB-DP-RPTR/SC | Bus: PROFIBUS DP; Fiber: SC single-mode | DP bus repeater + SC fiber, long-distance segment extension | Cross-factory PROFIBUS DP network (e.g., extending DP bus to remote workshop via SC fiber, distance >10km) |
| 2316373 | FB-DP-RPTR | Bus: PROFIBUS DP; Copper cable interface | Standard DP bus repeater, segment isolation and extension | Workshop-level DP bus extension (e.g., adding 32 DP nodes beyond the 32-node limit per segment) |
4. FB-DIAG Series (Fieldbus Diagnostic Modules)
Diagnostic modules for FF (Foundation Fieldbus) networks, enabling real-time fault monitoring and localization for fieldbus systems.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 2316297 | FB-DIAG/FF/NC | Fieldbus: FF; Diagnostic Type: NC (network communication) | FF bus communication fault diagnosis, protocol-level error detection | FF bus communication fault troubleshooting (e.g., locating FF network packet loss or protocol mismatch) |
| 2316284 | FB-DIAG/FF/LI | Fieldbus: FF; Diagnostic Type: LI (link integrity) | FF bus physical link diagnosis, cable/connector fault detection | FF bus physical layer maintenance (e.g., identifying damaged FF cables or loose connectors in chemical plant instrument networks) |
5. FB-xSP Series (Slot Interface Modules)
Modular slot units for distributing I/O, bus, or power interfaces, with optional isolation (ISO) for signal/device protection.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 2316312 | FB-12SP ISO | Slot Count: 12; Feature: ISO electrical isolation | 12 isolated slots for signal/device segmentation | High-reliability 12-slot interface distribution (e.g., mixed-voltage device slot management in medical equipment workshops) |
| 2316310 | FB-12SP | Slot Count: 12; No isolation | Standard 12-slot interface unit | General 12-slot interface distribution (e.g., workshop-level I/O module slot expansion) |
| 2316311 | FB-8SP ISO | Slot Count: 8; Feature: ISO isolation | 8 isolated slots for sensitive signal distribution | 8-slot isolated interface for precision sensor signals (e.g., laboratory-grade instrument slot management) |
| 2316307 | FB-6SP | Slot Count: 6; Standard type | 6-slot basic interface unit | Small-scale 6-slot interface distribution (e.g., robotic workstation I/O module slots) |
| 2316019 | FB-4SP | Slot Count: 4; Standard type | 4-slot compact interface unit | Compact 4-slot interface (e.g., individual equipment I/O/power slot management) |
| 2316052 | FB-2SP/E | Slot Count: 2; Feature: Enhanced (E-type) | 2 enhanced slots for harsh environments | 2-slot interface in high-interference environments (e.g., inverter-proximal device slot connection) |
| 2316352 | FB-2SP/24DC | Slot Count: 2; Power: 24V DC dedicated | 2-slot 24V DC power-specific interface | 2-slot 24V DC actuator/sensor interface (e.g., 2-group solenoid valve power/signal slots) |
| 2316051 | FB-2SP | Slot Count: 2; Standard type | Basic 2-slot interface unit | Miniature 2-slot interface (e.g., auxiliary sensor/indicator slot distribution) |
6. FB1/FB2 Series (Next-Gen Intelligent Slot Modules)
Advanced intelligent slot modules with configurable parameters, supporting high-speed signal transmission and precise slot management.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 2316417 | FB2-S1-12SP-T-0-16-00-0-0 | Series: FB2-S1; Slot Count:12; Type: T (twisted-pair); Voltage: 16V | 12-slot intelligent twisted-pair interface, 16V low-voltage support | Smart factory 12-slot low-voltage intelligent device interface (e.g., IoT sensor slot network) |
| 2316433 | FB2-S1-12SP-S-0-16-00-0-0 | Series: FB2-S1; Slot Count:12; Type: S (shielded); Voltage:16V | 12-slot shielded intelligent interface, anti-interference | High-EMI environment 12-slot intelligent device connection (e.g., inverter-proximal IoT module slots) |
| 2316446 | FB1-S1-6SP-S-0-10-00-0-0 | Series: FB1-S1; Slot Count:6; Type: S (shielded); Voltage:10V | 6-slot shielded low-voltage intelligent interface | Compact 6-slot 10V precision intelligent device slot (e.g., medical instrument IoT module slots) |
III. FB Series Nomenclature Decoding
FB[Generation]-[Sub-series]-[Specifications]-[Special Features]
- Generation (optional):
- Omitted = Traditional FB series;
- FB1/FB2 = Next-gen intelligent series (S1=smart control sub-series).
- Sub-series:
- Hx (HSP/HSC/HSB/HSA) = High-speed bus/power modules (HSP=power plug, HSC=controller, HSB=bus bridge, HSA=adapter);
- ET = Ethernet communication module;
- DP-RPTR = PROFIBUS DP repeater;
- DIAG = Diagnostic module;
- xSP = Slot interface module (x=slot count: 2/4/6/8/12).
- Specifications:
- Bus type: DP (PROFIBUS DP), PA (PROFIBUS PA), FF (Foundation Fieldbus);
- Fiber interface: SC (single-mode fiber);
- Slot count: 2SP/4SP/6SP/8SP/12SP (number of interface slots);
- Voltage: 24DC/16V/10V (power supply voltage for dedicated modules);
- Interface type: T (twisted-pair), S (shielded).
- Special Features:
- E = Enhanced industrial grade (wider temperature/anti-interference);
- ISO = Electrical isolation (signal/device protection);
- NC/LI = Diagnostic type (NC=network communication, LI=link integrity);
- PA = PROFIBUS PA bus support.
IV. 3-Step Quick Selection Technique
Step 1: Select Module Type Based on Functional Requirements
- Bus extension/communication:
- PROFIBUS DP extension: Choose FB-DP-RPTR (2316373/374); add SC for long-distance fiber transmission.
- High-speed bus/DP-PA hybrid: Pick FB-HSB series (2316370/381/382); select PA for field instrument integration, SC for fiber communication.
- Ethernet interconnection: Opt for FB-ET (2316048/050); E-type for harsh environments.
- Interface/slot distribution:
- 2-12 slot interface: Select FB-xSP series; ISO for isolation needs (2316311/312), 24DC for 24V dedicated slots (2316352).
- Intelligent slot management: Choose FB1/FB2 series (2316417/433/446); S-type for shielded/anti-interference scenarios.
- System diagnosis: For FF fieldbus, select FB-DIAG series (2316284/297); LI for physical link diagnosis, NC for communication fault detection.
- Power supply: Use FB-HSP-PLUG/24DC/6A (2316383) for high-current bus module power.
Step 2: Match Bus/Interface Specifications to Network Architecture
- PROFIBUS DP networks: Ensure modules support DP (e.g., FB-DP-RPTR, FB-HSB-DP).
- PA field instrument integration: Select PA-supported models (FB-HSB-DP/PA, FB-HSB-DP-SC/PA).
- Long-distance (>1km) transmission: Add SC fiber interface (FB-DP-RPTR/SC, FB-HSB-DP-SC).
- Slot quantity needs: Confirm device count; 2SP for mini-devices, 12SP for large-scale distribution.
Step 3: Add Special Features for Environmental/Functional Needs
- Harsh industrial environments: Choose E-enhanced models (FB-ET/E, FB-2SP/E) for wider temperature/anti-interference.
- Mixed-voltage/sensitive signals: Select ISO-isolated slots (FB-8SP ISO/12SP ISO) to prevent cross-interference.
- FF fieldbus maintenance: Pick FB-DIAG with LI (physical link) or NC (communication) diagnosis based on fault type.
V. Recommended Industry-Scenario Combinations
| Industry | Typical Scenario | Recommended Model Combination |
|---|---|---|
| Chemical Plant (FF/PA Instrument Network) | FF bus diagnosis + PA-DP hybrid bus + 8-slot isolated interface | 2316284 (FB-DIAG/FF/LI) + 2316370 (FB-HSB-DP/PA) + 2316311 (FB-8SP ISO) |
| Automotive Workshop (DP Bus Extension) | DP repeater (SC fiber) + 12-slot interface + Ethernet interconnection | 2316374 (FB-DP-RPTR/SC) + 2316310 (FB-12SP) + 2316050 (FB-ET/E) |
| Smart Factory (Intelligent Slot Management) | FB2 12-slot shielded interface + high-speed bus controller + 24V power plug | 2316433 (FB2-S1-12SP-S) + 2316371 (FB-HSC) + 2316383 (FB-HSP-PLUG/24DC/6A) |
| Medical Equipment Workshop (Isolated Slot) | 6-slot basic interface + 8-slot isolated interface + DP-PA fiber module | 2316307 (FB-6SP) + 2316311 (FB-8SP ISO) + 2316381 (FB-HSB-DP-SC/PA) |
VI. Selection Pitfall Avoidance Guide
- Bus protocol mismatch: FF fieldbus using DP diagnostic modules → Select FB-DIAG/FF series (2316284/297) to ensure FF protocol compatibility and accurate diagnosis.
- Isolation neglect: Mixed-voltage devices using non-ISO slots → Choose ISO-isolated models (2316311/312) to prevent voltage cross-interference and device damage.
- Long-distance transmission error: 10km DP networks using copper repeaters → Add SC fiber interface (2316374 FB-DP-RPTR/SC) to avoid signal attenuation and bus failure.
- Slot count insufficiency: 12-device networks using 6SP modules → Select 12SP models (2316310/312) to avoid multiple module cascading and wiring clutter.
- Harsh environment oversight: Outdoor modules using non-E-type models → Pick E-enhanced variants (2316050 FB-ET/E) to resist temperature extremes and electromagnetic interference.
Conclusion: Select the Right FB Module for Industrial Communication & Interface Flexibility
The Phoenix FB series provides targeted solutions for industrial bus extension, Ethernet interconnection, slot interface distribution, and system diagnosis, covering traditional fieldbus to next-gen intelligent slot networks.