Phoenix VAL-MS 230 Series Surge Protection Devices (SPDs) Selection Guide
Introduction: Comprehensive Surge Protection for Industrial Power Systems
The Phoenix VAL-MS 230 series offers high-performance Type 2 surge protection devices designed to safeguard industrial electrical systems against transient overvoltages caused by lightning strikes or switching operations. These DIN-rail mountable SPDs feature a modular design with replaceable protection inserts, making maintenance quick and cost-effective. With voltage ratings optimized for 230V AC systems (and variants for IT power systems), these devices provide reliable protection for industrial automation equipment, control cabinets, and process systems.
I. Key Advantages of VAL-MS 230 Series
-
Industrial-grade protection:
- Type 2 classification (IEC 61643-11) for main distribution and branch circuits
- High discharge capacity: Up to 40 kA (8/20μs) for heavy surge protection Phoenix Contact USA
- Fast response time: ≤25 ns for L-N protection, minimizing equipment exposure Phoenix Contact USA
-
Versatile system compatibility:
- Works with TN-S, TT, and IT power systems Phoenix Contact USA
- Multiple protection modes: 1+1, 2+0, 3+0, 3+1 configurations
- Special variants for IT systems (VAL-MS 230 IT series) with isolated neutral
-
Intelligent monitoring features:
- Visual fault indication: Clear status window shows "OK" or "FAULT"
- Remote signaling capability (FM variants): Contact for integration with building management systems Phoenix Contact USA
- Thermal monitoring: Protects against overheating and disconnects faulty modules
-
Modular design benefits:
- Replaceable protection inserts (UD-ST variants) without disconnecting wiring
- Space-efficient: Compact DIN-rail mounting (35.6mm to 71mm width) Phoenix Contact USA
- Easy installation: Screw connections (M5) with standardized torque requirements Phoenix Contact USA
II. Product Classification & Technical Parameter Table
1. Single-phase Protection Devices (1+1 Configuration)
| Part Number | Model Description | Protection Mode | Max Continuous Voltage | Nominal Discharge Current | Special Features |
|---|---|---|---|---|---|
| 2804429 | VAL-MS 230/1+1 | L-N | 275V AC | 20 kA | Standard version Phoenix Contact USA |
| 2804432 | VAL-MS 230/1+1-FM | L-N + Remote Signal | 275V AC | 20 kA | With fault monitoring contact |
| 5772032 | VAL-MS 230/1+1-FM | L-N + Remote Signal | 275V AC | 20 kA | Same as above |
| 5772029 | VAL-MS 230/1+1 | L-N | 275V AC | 20 kA | Same as 2804429 Phoenix Contact USA |
2. Two-phase Protection Devices (2+0 Configuration)
| Part Number | Model Description | Protection Mode | Max Continuous Voltage | Nominal Discharge Current | Special Features |
|---|---|---|---|---|---|
| 2800103 | VAL-MS 230/2+0 | L1-PE, L2-PE | 275V AC | 20 kA | Standard version |
| 2800102 | VAL-MS 230/2+0-FM | L1-PE, L2-PE + Remote Signal | 275V AC | 20 kA | With fault monitoring contact |
3. Three-phase Protection Devices (3+0 & 3+1 Configurations)
| Part Number | Model Description | Protection Mode | Max Continuous Voltage | Nominal Discharge Current | Special Features |
|---|---|---|---|---|---|
| 2838209 | VAL-MS 230/3+1 | 3L-N + N-PE | 275V AC (L-N)260V AC (N-PE) | 20 kA | Standard 3+1 protection |
| 2838199 | VAL-MS 230/3+1-FM | 3L-N + N-PE + Remote Signal | 275V AC (L-N)260V AC (N-PE) | 20 kA | With fault monitoring contact |
| 2908476 | VAL-MS 230/3+1 FM/32 | 3L-N + N-PE + Remote Signal | 275V AC (L-N)260V AC (N-PE) | 32 kA | Higher discharge capacity |
| 2858959 | VAL-MS 230/3+1-FM-UD | 3L-N + N-PE + Remote Signal + Replaceable Plug | 275V AC (L-N)260V AC (N-PE) | 20 kA | With replaceable protection insert |
| 1248960 | VAL-MS 230/3+1 FM-PT | 3L-N + N-PE + Remote Signal + Test Function | 275V AC (L-N)260V AC (N-PE) | 20 kA | With integrated test button |
| 5772294 | VAL-MS 230/3-FM | 3L-PE + Remote Signal | 275V AC | 20 kA | Three-phase to ground protection |
| 2839130 | VAL-MS 230/FM | Single-channel + Remote Signal | 275V AC | 20 kA | Single-phase protection with monitoring |
4. IT System Protection Devices
| Part Number | Model Description | Protection Mode | Max Continuous Voltage | Nominal Discharge Current | Special Features |
|---|---|---|---|---|---|
| 2858548 | VAL-MS 230 IT/3+1 | 3L-N + N-PE (for IT systems) | 385V AC (L-N)260V AC (N-PE) | 20 kA | For isolated neutral IT systems |
| 2858551 | VAL-MS 230 IT/3+1-FM | 3L-N + N-PE + Remote Signal (for IT systems) | 385V AC (L-N)260V AC (N-PE) | 20 kA | With fault monitoring for IT systems Phoenix Contact USA |
| 2801497 | VAL-MS 230IT/3+1/FM/S1 | 3L-N + N-PE + Remote Signal + Special Version | 385V AC (L-N)260V AC (N-PE) | 20 kA | Special variant for specific IT applications |
| 5772320 | VAL-MS 230 IT/3 | 3L-PE (for IT systems) | 385V AC | 20 kA | Three-phase to ground protection for IT systems |
| 2807599 | VAL-MS 230 IT ST | Single-channel plug for IT systems | 385V AC | 20 kA | Replaceable plug for IT systems |
| 5772184 | VAL-MS 230 IT | Single-channel for IT systems | 385V AC | 20 kA | Standard version for IT systems |
5. Special Function Devices
| Part Number | Model Description | Protection Mode | Max Continuous Voltage | Nominal Discharge Current | Special Features |
|---|---|---|---|---|---|
| 2858962 | VAL-MS 230-UD-ST | Single-channel + Replaceable Plug | 275V AC | 20 kA | Replaceable protection insert |
| 2798844 | VAL-MS 230 ST | Single-channel + Replaceable Plug | 275V AC | 20 kA | Standard replaceable plug version |
| 2839143 | VAL-MS 230 VF/FM | Single-channel + Voltage Free Contact + Remote Signal | 275V AC | 20 kA | With voltage-free auxiliary contact |
| 5772197 | VAL-MS 230 IT/FM | Single-channel for IT systems + Remote Signal | 385V AC | 20 kA | Single-channel IT protection with monitoring |
| 2839127 | VAL-MS 230 | Single-channel standard version | 275V AC | 20 kA | Basic single-phase protection |
III. VAL-MS Series Nomenclature Decoding
VAL-MS [Voltage][System Type][Protection Mode][Features][Version]
| Component | Description | Options |
|---|---|---|
| VAL-MS | Product series identifier | Fixed |
| 230 | Nominal voltage: 230V AC | 230, 230IT (for IT systems) |
| IT | System type: IT power system | IT (for isolated neutral systems); omitted for TN/TT systems |
| /3+1 | Protection mode: 3 phases + neutral to ground | /1+1, /2+0, /3+0, /3+1, /3 (3-phase to ground) |
| -FM | Features: Remote monitoring contact | -FM (fault monitoring), -UD (replaceable plug), -ST (standard plug), -PT (test function) |
| /S1 | Special version identifier | /S1, /32 (32kA discharge), etc. |
IV. 4-Step Selection Methodology
Step 1: Determine Power System Type
- TN-S/TT Systems: Use standard VAL-MS 230 series Phoenix Contact USA
- IT Systems: Use VAL-MS 230 IT series with higher insulation (385V AC rating)
- Mixed Systems: Consult technical documentation for compatibility
Step 2: Select Protection Mode Based on Application
- 1+1 Configuration: Single-phase applications (lighting, small machinery) Phoenix Contact USA
- 2+0 Configuration: Two-phase systems or split-phase applications
- 3+0 Configuration: Three-phase equipment without neutral connection
- 3+1 Configuration: Three-phase systems with neutral-to-ground protection (most common in industrial settings)
Step 3: Choose Required Features
- -FM (Fault Monitoring): Necessary for critical applications requiring remote alarm indication Phoenix Contact USA
- -UD-ST (Replaceable Plug): Ideal for maintenance-intensive environments (allows plug replacement without rewiring)
- -PT (Test Function): Recommended for periodic compliance verification
- VF (Voltage Free Contact): Useful for integrating with PLCs or building management systems
Step 4: Determine Discharge Current Rating
- Standard Applications: 20 kA (8/20μs) is sufficient Phoenix Contact USA
- High-Surge Environments: Consider 32 kA variants (e.g., 2908476)
- Lightning-Prone Areas: Consult local lightning protection standards for appropriate ratings
V. Recommended Application Scenarios
| Industry Application | Recommended Model | Rationale |
|---|---|---|
| Industrial Automation | 2838199 (VAL-MS 230/3+1-FM) | 3+1 protection for three-phase machinery with remote fault monitoring |
| Process Control Systems | 2858551 (VAL-MS 230 IT/3+1-FM) | IT system compatibility with surge protection and fault signaling Phoenix Contact USA |
| Manufacturing Equipment | 2858962 (VAL-MS 230-UD-ST) | Replaceable plug design reduces maintenance downtime |
| Building Management Systems | 2839143 (VAL-MS 230 VF/FM) | Voltage-free contact integrates with BMS for comprehensive monitoring |
| Solar Inverters (IT Systems) | 2801497 (VAL-MS 230IT/3+1/FM/S1) | Special variant for photovoltaic inverters in isolated IT networks |
VI. Important Installation & Maintenance Considerations
-
Mounting: Always install on 35mm DIN rail (NS 35/7.5) in a vertical position for proper heat dissipation Phoenix Contact USA
-
Wiring Requirements:
- Use stranded or solid conductors (1.5-25mm² flexible, 1.5-35mm² rigid) Phoenix Contact USA
- Torque connections to 3 Nm (for 1.5-16mm²) or 4.5 Nm (for 25-35mm²) Phoenix Contact USA
- Maintain proper wire stripping length (16mm) for secure connections Phoenix Contact USA
-
Protection Coordination:
- Install upstream fuses (max 80A gG for V-type wiring) to protect against short circuits Phoenix Contact USA
- Ensure proper coordination with upstream Type 1 SPDs in lightning-prone areas
-
Maintenance Best Practices:
- Regularly inspect visual status indicators
- For -UD-ST variants, keep spare protection plugs on hand
- Replace entire module if fault indication persists after plug replacement
VII. Key Technical Specifications Comparison
| Parameter | Standard VAL-MS 230 | VAL-MS 230 IT Series |
|---|---|---|
| Nominal Voltage | 230V AC (TN/TT) | 230V AC (IT systems) |
| Max Continuous Voltage | 275V AC (L-N/L-PE) | 385V AC (L-N/L-PE) |
| Nominal Discharge Current | 20 kA (8/20μs) | 20 kA (8/20μs) Phoenix Contact USA |
| Max Discharge Current | 40 kA (8/20μs) | 40 kA (8/20μs) Phoenix Contact USA |
| Voltage Protection Level | ≤1.35kV (L-N); ≤1.6kV (L-PE) | ≤1.8kV (L-N); ≤2.2kV (L-PE) Phoenix Contact USA |
| Response Time | ≤25ns (L-N); ≤100ns (L-PE) | ≤25ns (L-N); ≤100ns (L-PE) Phoenix Contact USA |
| Operating Temperature | -40°C to +80°C | -40°C to +80°C Phoenix Contact USA |
| Degree of Protection | IP20 (when all terminals used) | IP20 (when all terminals used) Phoenix Contact USA |
VIII. Avoiding Common Selection Pitfalls
-
Incorrect System Type Selection:
- Using standard VAL-MS 230 for IT systems can lead to premature failure
- Always verify power system type (TN-S/TT vs. IT) before selecting
-
Inadequate Protection Mode:
- Single-phase loads connected to 3-phase systems require 1+1 protection, not 3+0
- Three-phase motors with neutral connections need 3+1 protection for complete safety
-
Neglecting Monitoring Needs:
- Critical applications without -FM monitoring may fail without warning
- Remote signaling is essential for unattended installations Phoenix Contact USA
-
Ignoring Maintenance Convenience:
- High-traffic areas benefit from -UD-ST variants (plug replacement in minutes)
- Standard versions require complete disassembly for maintenance
Conclusion: Optimizing Surge Protection for Your Industrial Needs
The Phoenix VAL-MS 230 series provides reliable, flexible surge protection solutions for industrial power systems.