Phoenix SH Series 8-Core Industrial Connectors Selection Guide

Opening: High-Density 8-Core Connection Solutions for Industrial Signal & Power Transmission

The Phoenix SH series is a portfolio of industrial-grade 8-core connectors designed for reliable signal and power transmission in harsh factory environments. Covering signal (ES series) and power (EP series) categories, these connectors support diverse voltage specifications (48/58/68/008) and feature specialized coding (LD/LB/AWA) and locking structures for anti-vibration and anti-misconnection. With IP67 protection (when mated), wide operating temperature (-40°C to +85°C), and anti-corrosion housing, they are widely used in robotic workstations, production line sensors, and industrial actuator connections, ensuring stable multi-channel transmission in high-interference and high-vibration scenarios.


I. Core Advantages of the SH Series

  1. Dual-category coverage:
    • ES series (signal): For 8-channel low-voltage signal transmission (e.g., sensor feedback, encoder signals), with anti-interference shielding and precise coding;
    • EP series (power): For 8-channel medium-power distribution (e.g., actuator power, module power supply), with high current-bearing capacity and overload protection.
  2. Multi-specification compatibility: Supports 48/58/68/008 voltage/interface specifications, adapting to different industrial control system voltage levels and interface standards.
  3. Industrial-grade reliability:
    • IP67 protection (when mated) for dust and water resistance, suitable for outdoor/harsh workshop environments;
    • Zinc alloy housing with anti-corrosion plating, resistant to salt spray and chemical corrosion;
    • Anti-vibration locking structure (LD/LB series), ensuring connection stability under 10g vibration (robotic joints/machinery).
  4. Anti-misconnection design: Specialized coding suffixes (AWA/AAC/LD/LB) prevent cross-connection of different voltage/signals, reducing system faults.
  5. Modular installation: DIN rail or panel-mounted options, compatible with Phoenix control cabinet infrastructure for seamless integration.

II. Product Classification & Detailed Parameter Table

The SH series is categorized into signal-type (ES) and power-type (EP) by function, with sub-variants based on voltage specification and coding.

1. ES Series (8-Core Signal Connectors)

For 8-channel low-voltage industrial signal transmission, including ESS/ESD/ESC sub-types with different signal precision and coding.

Sub-type Part Number Complete Model Core Parameters Key Features Application Scenario
ESS (Standard Signal) 1621568 SH-8ESS48AWA00S Core Count: 8; Spec: 48; Coding: AWA00; Feature: S (shielded) 8-core standard signal, AWA00 coding, shielded General 8-channel sensor signal transmission (e.g., workshop conveyor belt proximity sensor array)
  1621524 SH-8ESS48A8LDLS Core Count:8; Spec:48; Coding:A8LDL; Feature:S 8-core standard signal, A8LDL anti-vibration coding Vibration-prone 8-channel signal (e.g., robotic arm joint position sensor feedback)
  1621528 SH-8ESS48A8LB1S Core Count:8; Spec:48; Coding:A8LB1; Feature:S 8-core standard signal, A8LB1 locking coding 8-channel signal with mechanical locking (e.g., packaging machine photoelectric sensor connection)
ESD (High-Precision Signal) 1238527 SH-8ESD68A8LB2SX Core Count:8; Spec:68; Coding:A8LB2; Feature:SX (enhanced shielded) 8-core high-precision signal, 68 spec, enhanced shielding High-precision 8-channel signal (e.g., industrial vision system camera trigger signals)
  1157073 SH-8ESD68A8LB2S Core Count:8; Spec:68; Coding:A8LB2; Feature:S 8-core high-precision signal, 68 spec, standard shielding Laboratory-grade 8-channel sensor signal (e.g., precision weighing equipment data transmission)
ESC (Special Signal) 1621567 SH-8ESC58AWA00S Core Count:8; Spec:58; Coding:AWA00; Feature:S 8-core special signal, 58 spec, AWA00 coding Custom 8-channel signal (e.g., legacy control system 58-spec encoder signals)
  1621559 SH-8ESC58AAC00S Core Count:8; Spec:58; Coding:AAC00; Feature:S 8-core special signal, 58 spec, AAC00 coding 8-channel signal with AAC protocol coding (e.g., specialized PLC module communication)
  1621539 SH-8ESC58A9LDLS Core Count:8; Spec:58; Coding:A9LDL; Feature:S 8-core special signal, 58 spec, A9LDL anti-vibration coding Vibration-prone 58-spec 8-channel signal (e.g., mining equipment sensor feedback)
  1621541 SH-8ESC58A9LB3S Core Count:8; Spec:58; Coding:A9LB3; Feature:S 8-core special signal, 58 spec, A9LB3 locking coding 8-channel 58-spec signal with heavy-duty locking (e.g., heavy machinery pressure sensor connection)
  1621517 SH-8ESC58A8LDLS Core Count:8; Spec:58; Coding:A8LDL; Feature:S 8-core special signal, 58 spec, A8LDL coding General 58-spec 8-channel signal (e.g., workshop auxiliary equipment sensor transmission)
  1621997 SH-8ESC58A8LDL Core Count:8; Spec:58; Coding:A8LDL; No S suffix 8-core special signal, 58 spec, non-shielded Low-interference 58-spec 8-channel signal (e.g., control cabinet internal module communication)
  1621522 SH-8ESC58A8LB2S Core Count:8; Spec:58; Coding:A8LB2; Feature:S 8-core special signal, 58 spec, A8LB2 coding 8-channel 58-spec signal with medium locking (e.g., pharmaceutical equipment sensor connection)

2. EP Series (8-Core Power Connectors)

For 8-channel medium-power distribution, including EPS/EPD/EPC/EP00 sub-types for different power specifications and coding.

Sub-type Part Number Complete Model Core Parameters Key Features Application Scenario
EPS (Standard Power) 1621570 SH-8EPS48AWA00S Core Count:8; Spec:48; Coding:AWA00; Power Grade: Standard 8-core standard power, 48 spec, AWA00 coding General 8-channel power distribution (e.g., workshop 8-group indicator light power supply)
  1621534 SH-8EPS48A8LDLS Core Count:8; Spec:48; Coding:A8LDL; Power Grade: Standard 8-core standard power, 48 spec, A8LDL anti-vibration coding Vibration-prone 8-channel power (e.g., robotic gripper 8-group solenoid valve power)
  1621538 SH-8EPS48A8LB1S Core Count:8; Spec:48; Coding:A8LB1; Power Grade: Standard 8-core standard power, 48 spec, A8LB1 locking coding 8-channel power with mechanical locking (e.g., packaging machine actuator power supply)
EPD (High-Power) 1157072 SH-8EPD68A8LB2S Core Count:8; Spec:68; Coding:A8LB2; Power Grade: High 8-core high-power, 68 spec, A8LB2 coding 8-channel high-power distribution (e.g., industrial heater 8-group heating element power)
EPC (Special Power) 1621549 SH-8EPC58A9LDLS Core Count:8; Spec:58; Coding:A9LDL; Power Grade: Special 8-core special power, 58 spec, A9LDL anti-vibration coding Vibration-prone 58-spec 8-channel power (e.g., mining equipment actuator power supply)
  1621552 SH-8EPC58A9LB2S Core Count:8; Spec:58; Coding:A9LB2; Power Grade: Special 8-core special power, 58 spec, A9LB2 coding 8-channel 58-spec power with medium locking (e.g., legacy control system module power)
  1621553 SH-8EPC58A9LB1S Core Count:8; Spec:58; Coding:A9LB1; Power Grade: Special 8-core special power, 58 spec, A9LB1 coding 8-channel 58-spec power with basic locking (e.g., auxiliary workshop equipment power)
  1621529 SH-8EPC58A8LDLS Core Count:8; Spec:58; Coding:A8LDL; Power Grade: Special 8-core special power, 58 spec, A8LDL coding General 58-spec 8-channel power (e.g., control cabinet internal 8-group module power)
  1622007 SH-8EPC58A8LDL Core Count:8; Spec:58; Coding:A8LDL; Non-shielded 8-core special power, 58 spec, non-shielded Low-interference 58-spec 8-channel power (e.g., cabinet-proximal low-power module supply)
  1621531 SH-8EPC58A8LB3S Core Count:8; Spec:58; Coding:A8LB3; Power Grade: Special 8-core special power, 58 spec, A8LB3 heavy locking 8-channel 58-spec power with heavy-duty locking (e.g., heavy machinery auxiliary actuator power)
  1621532 SH-8EPC58A8LB2S Core Count:8; Spec:58; Coding:A8LB2; Power Grade: Special 8-core special power, 58 spec, A8LB2 coding 8-channel 58-spec power with medium locking (e.g., pharmaceutical equipment actuator power)
EP00 (Universal Power) 1627077 SH-8EP008A8LDLS Core Count:8; Spec:008; Coding:A8LDL; Power Grade: Universal 8-core universal power, 008 spec, A8LDL coding Universal 8-channel power for multi-voltage systems (e.g., mixed-voltage workshop equipment power)

III. SH Series Nomenclature Decoding

SH-8[Function Type][Spec Code][Coding Suffix][Special Feature]

  • SH: Product series identifier (8-core industrial connector for signal/power transmission).
  • 8: Fixed core count (8-channel, for multi-point signal or power distribution).
  • Function Type:
    • ES = Signal-type (sub-divided into ESS/ESD/ESC: ESS=standard signal, ESD=high-precision signal, ESC=special signal);
    • EP = Power-type (sub-divided into EPS/EPD/EPC/EP00: EPS=standard power, EPD=high-power, EPC=special power, EP00=universal power).
  • Spec Code:
    • 48/58/68/008 = Voltage/interface specification code (48=standard low-voltage, 58=special legacy spec, 68=high-precision signal spec, 008=universal power spec).
  • Coding Suffix:
    • AWA00/AAC00 = General protocol coding (for system compatibility);
    • A8/A9 = Coding level (A8=standard coding, A9=enhanced anti-vibration coding);
    • LDL = Anti-vibration locking coding (for robotic/machinery scenarios);
    • LB1/LB2/LB3 = Mechanical locking coding (LB1=basic lock, LB2=medium lock, LB3=heavy-duty lock).
  • Special Feature:
    • S = Shielded (enhanced EMI protection for signal/power);
    • SX = Enhanced shielded (for high-precision signal);
    • No S suffix = Non-shielded (for low-interference cabinet-internal scenarios).

IV. 3-Step Quick Selection Technique

Step 1: Select Function Type Based on Transmission Demand

  • 8-channel signal transmission: Choose ES series;
    • Standard sensor signals: ESS sub-type (e.g., 1621568 SH-8ESS48AWA00S);
    • High-precision vision/encoder signals: ESD sub-type (e.g., 1238527 SH-8ESD68A8LB2SX);
    • Legacy/custom 58-spec signals: ESC sub-type (e.g., 1621567 SH-8ESC58AWA00S).
  • 8-channel power distribution: Select EP series;
    • Standard indicator/actuator power: EPS sub-type (e.g., 1621570 SH-8EPS48AWA00S);
    • High-power heater/actuator power: EPD sub-type (e.g., 1157072 SH-8EPD68A8LB2S);
    • Legacy 58-spec power: EPC sub-type (e.g., 1621549 SH-8EPC58A9LDLS);
    • Universal multi-voltage power: EP00 sub-type (1627077 SH-8EP008A8LDLS).

Step 2: Match Spec Code to System Voltage/Protocol

  • 48-spec systems: Select 48 suffix models (all ESS/EPS 48-spec variants) for standard industrial low-voltage signal/power;
  • 58-spec legacy systems: Pick 58 suffix models (ESC/EPC 58-spec variants) for custom legacy equipment;
  • 68-spec high-precision systems: Choose 68 suffix models (ESD/EPD 68-spec variants) for high-precision signal/high-power transmission;
  • Universal multi-voltage systems: Opt for 008-spec EP00 model (1627077) for mixed-voltage power distribution.

Step 3: Add Coding/Special Features for Environmental Needs

  • High-vibration scenarios (robots/machinery): Select LDL anti-vibration coding (e.g., 1621524 SH-8ESS48A8LDLS, 1621534 SH-8EPS48A8LDLS);
  • Mechanical locking needs: Pick LB1/LB2/LB3 locking coding (LB3 for heavy-duty, e.g., 1621541 SH-8ESC58A9LB3S);
  • High-interference environments: Choose S/SX shielded models (SX for high-precision signal, e.g., 1238527 SH-8ESD68A8LB2SX);
  • Cabinet-internal low-interference scenarios: Use non-shielded models (no S suffix, e.g., 1621997 SH-8ESC58A8LDL).

V. Recommended Industry-Scenario Combinations

Industry Typical Scenario Recommended Model Combination
Automotive Robotics 8-channel robotic joint sensor signal (vibration-prone) + 8-channel gripper actuator power 1621524 (SH-8ESS48A8LDLS signal) + 1621534 (SH-8EPS48A8LDLS power)
Precision Electronics Manufacturing 8-channel vision system high-precision signal + 8-channel equipment module power 1238527 (SH-8ESD68A8LB2SX signal) + 1157072 (SH-8EPD68A8LB2S power)
Legacy Control System Upgrade 8-channel 58-spec legacy encoder signal + 58-spec actuator power 1621517 (SH-8ESC58A8LDLS signal) + 1621529 (SH-8EPC58A8LDLS power)
Heavy Machinery 8-channel heavy-duty sensor signal (heavy locking) + 8-channel auxiliary actuator power 1621541 (SH-8ESC58A9LB3S signal) + 1621531 (SH-8EPC58A8LB3S power)
Universal Workshop Power 8-channel mixed-voltage equipment power (universal spec) 1627077 (SH-8EP008A8LDLS)

VI. Selection Pitfall Avoidance Guide

  1. Function type mismatch: Power distribution using ES signal connectors → Select EP power series (e.g., EPS/EPD) to avoid current overload and connector burnout.
  2. Spec code error: 58-spec legacy systems using 48-spec connectors → Pick 58-spec ESC/EPC models (e.g., 1621567) to ensure protocol/voltage compatibility and prevent signal/power failure.
  3. Vibration scenario oversight: Robotic workstations using non-LDL coding connectors → Choose LDL anti-vibration models (e.g., 1621524) to avoid connection loosening and signal/power loss.
  4. Shielding neglect: High-interference environments using non-shielded models → Select S/SX shielded variants (e.g., 1238527) to suppress EMI and ensure signal integrity.
  5. Locking coding insufficiency: Heavy machinery using LB1 basic locking → Opt for LB3 heavy-duty locking (e.g., 1621541) to prevent connector disengagement under mechanical impact.

Conclusion: Select the Right SH Connector for 8-Core Industrial Transmission

The Phoenix SH series provides targeted 8-core connection solutions for industrial signal and power transmission, covering standard/high-precision/special signals and standard/high-power/special power categories, with diverse spec codes and coding features for harsh environment adaptation. 