Phoenix SACC-M12MSB/SACC-M12MS Series Industrial M12 Circular Connectors Selection Guide

Opening: Precision M12 Connectivity Solutions for Industrial Signal & Power Transmission

The Phoenix SACC-M12MSB and SACC-M12MS series represent industrial-grade M12 circular connectors engineered for reliable signal, power, and data transmission in factory automation, robotics, and industrial control systems. Covering two core sub-series—SACC-M12MSB (5-core specialized) and SACC-M12MS (4/5-core versatile)—these connectors feature M12 industry-standard interfaces, 2/3/4/5-core configurations, and functional variants (signal: SC; power: PL; coded signal: QO; general connection: CON). Key attributes include shielded (SH) EMI protection, IP67 ingress protection (when mated), diverse cable gland options (PG7/9/11, DM diameter ranges), and regional certifications (AU/VA/IB). Widely used for sensor/actuator wiring, industrial Ethernet, and power distribution, they ensure robust performance in harsh industrial environments.


I. Core Advantages of the Series

  1. M12 Standard Compatibility & Functional Diversity

    • Industry-universal M12 interface (male configuration as standard) for seamless integration with global industrial sensors, PLCs, and actuators;
    • Functional differentiation:
      • SC: Signal transmission (high-precision sensor data);
      • PL: Power delivery (low-voltage actuator supply);
      • QO: Coded signal (industrial Ethernet/Protocol-compatible);
      • CON: General-purpose connection (versatile wiring);
    • Core count options (2/3/4/5) to match signal/power channel requirements.
  2. Industrial-Grade Reliability & Protection

    • SH (Shielded) variants: Braided shielding suppresses EMI/RFI interference, critical for inverter-proximal or high-noise environments;
    • IP67 protection (when mated) against dust, water, and oil, suitable for workshop floors and outdoor field installations;
    • Gold-plated contacts ensure low contact resistance (≤20mΩ) and ≥10,000 mating cycles for long service life.
  3. Flexible Installation & Regional Compliance

    • Cable gland options: PG7 (small cables), PG9 (standard), PG11 (power cables), and DM (diameter-specific: 3-5mm/5-8mm) for precise cable diameter matching;
    • Regional certifications: AU (Australian compliance), VA (voltage-rated), IB (industry-specific), ensuring regulatory alignment for global projects;
    • Specialized variants: PWR (power-optimized), CCL (click-lock), SKIN (thin-profile), and DUO (dual-function) for targeted use cases.
  4. Plug-and-Play Deployment

    • Tool-free locking mechanisms (twist-lock or click-lock) for quick on-site assembly;
    • Pre-configured contact arrangements for signal/power separation, reducing wiring errors;
    • Compact design (M12 form factor) for space-constrained control cabinets and device cavities.

II. Product Classification & Detailed Parameter Table

The series is categorized by sub-series (SACC-M12MSB/SACC-M12MS) and functional type (SC/PL/QO/CON) with sub-variants based on core count, cable gland/line diameter, shielding, and certifications.

1. SACC-M12MSB Series (5-Core Specialized M12 Connectors)

5-core M12MSB sub-series focused on signal, power, and general connection, with shielded and certified variants.

Part Number Complete Model Core Parameters Key Features Application Scenario
Signal (SC) 1513570 SACC-M12MSB-5SC SH Core Count:5; Type:SC (signal); Shielding:SH; Protection:IP67 5-channel high-precision sensor signal transmission (e.g., vision system 5-point data collection)
Power (PL) 1424674 SACC-M12MSB-5PL SH IB Core Count:5; Type:PL (power); Shielding:SH; Certification:IB; Current Rating:High 5-core power supply for industrial actuators (e.g., robotic gripper 5-channel power delivery)
  1424662 SACC-M12MSB-5PL SH Core Count:5; Type:PL (power); Shielding:SH 5-core general power transmission (e.g., 5-group solenoid valve power wiring)
General Connection (CON) 1401096 SACC-M12MSB-5CON-PG9 SH XL PB Core Count:5; Type:CON; Gland:PG9; Shielding:SH; Feature:XL (extended length) + PB 5-channel PG9 cable connection (e.g., control cabinet internal 5-module wiring)
  1507764 SACC-M12MSB-5CON-PG9 SH AU Core Count:5; Type:CON; Gland:PG9; Shielding:SH; Certification:AU Australian-market 5-channel connection (e.g., mining equipment 5-sensor wiring)
  1440148 SACC-M12MSB-5CON-DM 5-8 SH VA Core Count:5; Type:CON; Cable Range:DM 5-8mm; Shielding:SH; Certification:VA 5-channel 5-8mm cable connection (e.g., heavy-duty sensor 5-signal transmission)
3-Core Power (PL) 1424695 SACC-M12MSB-3PL SH PB Core Count:3; Type:PL (power); Shielding:SH; Feature:PB 3-core power supply (e.g., 3-phase small motor power wiring)
2-Core Power (PL) 1424678 SACC-M12MSB-2PL SH PB Core Count:2; Type:PL (power); Shielding:SH; Feature:PB 2-core low-voltage power transmission (e.g., 24V DC sensor power supply)

2. SACC-M12MS Series (4/5-Core Versatile M12 Connectors)

4/5-core M12MS sub-series with diverse functional types (SC/PL/QO/CON), line diameters, and installation options.

2.1 5-Core SACC-M12MS Variants

Part Number Complete Model Core Parameters Key Features Application Scenario
General Connection (CON) 1553187 SACC-M12MS-5CON-PG 7-VA Core Count:5; Type:CON; Gland:PG7; Certification:VA 5-channel PG7 small-cable connection (e.g., miniature sensor 5-signal wiring)
  1693416 SACC-M12MS-5CON-PG 7-SH Core Count:5; Type:CON; Gland:PG7; Shielding:SH 5-channel shielded PG7 connection (e.g., high-interference miniature sensor wiring)
  1663116 SACC-M12MS-5CON-PG 7-M Core Count:5; Type:CON; Gland:PG7; Gender:Male 5-core male PG7 connector (e.g., male-interface sensor 5-signal transmission)
  1662256 SACC-M12MS-5CON-PG 7 Core Count:5; Type:CON; Gland:PG7 5-channel basic PG7 connection (e.g., auxiliary equipment 5-signal wiring)
  1440025 SACC-M12MS-5CON-DM 5-8 SH VA Core Count:5; Type:CON; Cable Range:DM 5-8mm; Shielding:SH; Certification:VA 5-channel 5-8mm shielded connection (e.g., outdoor sensor 5-signal transmission)
  1440012 SACC-M12MS-5CON-DM 3-5 SH VA Core Count:5; Type:CON; Cable Range:DM 3-5mm; Shielding:SH; Certification:VA 5-channel 3-5mm small-cable shielded connection (e.g., laboratory instrument wiring)

2.2 4-Core SACC-M12MS Variants (Signal: SC)

Part Number Complete Model Core Parameters Key Features Application Scenario
1559767 SACC-M12MS-4SC SH CCL Core Count:4; Type:SC (signal); Shielding:SH; Feature:CCL (click-lock) 4-channel click-lock shielded signal transmission (e.g., quick-connect sensor wiring)  
1513253 SACC-M12MS-4SC SH Core Count:4; Type:SC (signal); Shielding:SH 4-channel shielded signal transmission (e.g., 4-group proximity sensor data collection)  
1513716 SACC-M12MS-4SC M Core Count:4; Type:SC (signal); Gender:Male 4-core male signal connector (e.g., male-interface encoder signal transmission)  

2.3 4-Core SACC-M12MS Variants (Coded Signal: QO)

Part Number Complete Model Core Parameters Key Features Application Scenario
1641785 SACC-M12MS-4QO-0,75-M Core Count:4; Type:QO (coded signal); Wire Gauge:0.75mm²; Gender:Male 4-channel 0.75mm² coded signal (e.g., PROFINET QO-coded sensor connection)  
1641769 SACC-M12MS-4QO-0,75 Core Count:4; Type:QO (coded signal); Wire Gauge:0.75mm² 4-channel 0.75mm² coded signal transmission (e.g., industrial Ethernet QO-coded devices)  
1426360 SACC-M12MS-4QO-0,5-CM VA Core Count:4; Type:QO (coded signal); Wire Gauge:0.5mm²; Feature:CM (click-lock) + VA 4-channel 0.5mm² click-lock coded signal (e.g., compact QO-coded actuator control)  
1440753 SACC-M12MS-4QO-0,34-VA Core Count:4; Type:QO (coded signal); Wire Gauge:0.34mm²; Certification:VA 4-channel 0.34mm² thin-wire coded signal (e.g., miniature QO-coded sensor wiring)  
1641691 SACC-M12MS-4QO-0,34-M Core Count:4; Type:QO (coded signal); Wire Gauge:0.34mm²; Gender:Male 4-core male 0.34mm² coded signal (e.g., male-interface QO-coded encoder)  
1641714 SACC-M12MS-4QO-0,34 Core Count:4; Type:QO (coded signal); Wire Gauge:0.34mm² 4-channel 0.34mm² basic coded signal (e.g., low-power QO-coded device connection)  

2.4 4-Core SACC-M12MS Variants (Power: PL)

Part Number Complete Model Core Parameters Key Features Application Scenario
1424699 SACC-M12MS-4PL SH CCL Core Count:4; Type:PL (power); Shielding:SH; Feature:CCL (click-lock) 4-channel click-lock shielded power transmission (e.g., quick-connect actuator power)  
1424666 SACC-M12MS-4PL SH Core Count:4; Type:PL (power); Shielding:SH 4-channel shielded power transmission (e.g., 4-group solenoid valve power supply)  
1424657 SACC-M12MS-4PL M Core Count:4; Type:PL (power); Gender:Male 4-core male power connector (e.g., male-interface actuator power wiring)  
1424691 SACC-M12MS-4PL Core Count:4; Type:PL (power) 4-channel basic power transmission (e.g., auxiliary equipment 4-core power supply)  

2.5 4-Core SACC-M12MS Variants (General Connection: CON)

Part Number Complete Model Core Parameters Key Features Application Scenario
1523230 SACC-M12MS-4CON-PG9-M Core Count:4; Type:CON; Gland:PG9; Gender:Male 4-core male PG9 connection (e.g., male-interface sensor 4-signal wiring)  
1404415 SACC-M12MS-4CON-PG11-M PWR Core Count:4; Type:CON; Gland:PG11; Gender:Male; Feature:PWR (power-optimized) 4-channel PG11 power-focused connection (e.g., high-current actuator power wiring)  
1507052 SACC-M12MS-4CON-PG11-DUO-M Core Count:4; Type:CON; Gland:PG11; Gender:Male; Feature:DUO (dual-function) 4-channel dual-function PG11 connection (e.g., mixed signal/power transmission)  
1553174 SACC-M12MS-4CON-PG 9-VA Core Count:4; Type:CON; Gland:PG9; Certification:VA 4-channel PG9 VA-certified connection (e.g., regulatory-compliant sensor wiring)  
1501540 SACC-M12MS-4CON-PG 9-SH Core Count:4; Type:CON; Gland:PG9; Shielding:SH 4-channel shielded PG9 connection (e.g., high-interference 4-sensor wiring)  
1553161 SACC-M12MS-4CON-PG 7-VA Core Count:4; Type:CON; Gland:PG7; Certification:VA 4-channel PG7 small-cable VA-certified connection (e.g., miniature regulatory-compliant devices)  
1693830 SACC-M12MS-4CON-PG 7-SH Core Count:4; Type:CON; Gland:PG7; Shielding:SH 4-channel shielded PG7 connection (e.g., high-interference miniature sensor wiring)  
1556870 SACC-M12MS-4CON-PG 7-M SKIN Core Count:4; Type:CON; Gland:PG7; Gender:Male; Feature:SKIN (thin-profile) 4-core thin-profile PG7 male connection (e.g., space-constrained device wiring)  
1421125 SACC-M12MS-4CON-PG 7-M PWR Core Count:4; Type:CON; Gland:PG7; Gender:Male; Feature:PWR (power-optimized) 4-channel PG7 power-focused male connection (e.g., small-power actuator wiring)  
1662528 SACC-M12MS-4CON-PG 7-M Core Count:4; Type:CON; Gland:PG7; Gender:Male 4-core male PG7 basic connection (e.g., male-interface miniature device wiring)  
1681088 SACC-M12MS-4CON-PG 7 Core Count:4; Type:CON; Gland:PG7 4-channel basic PG7 connection (e.g., auxiliary miniature device wiring)  

III. Nomenclature Decoding: Understanding the Part Number System

SACC-M12[Sub-series]-[Core Count][Function Type]-[Installation/Wire Gauge]-[Special Features/Certifications]

  • SACC: Product series identifier (industrial circular connectors for M12 interfaces).
  • Sub-series:
    • M12MSB = 5-core specialized M12 connector (focused on power/signal integration);
    • M12MS = 4/5-core versatile M12 connector (broad functional coverage).
  • Core Count: 2/3/4/5 = Number of contacts (matches signal/power channel requirements).
  • Function Type:
    • SC = Signal (high-precision sensor/data transmission);
    • PL = Power (low-voltage actuator/device power supply);
    • QO = Coded signal (protocol-compatible, e.g., PROFINET/QO coding);
    • CON = General connection (versatile signal/power wiring).
  • Installation/Wire Gauge:
    • PG7/9/11 = Cable gland size (matches cable diameter: PG7=small, PG9=standard, PG11=large);
    • DM X-Y = Cable diameter range (e.g., DM 5-8 = 5-8mm cable compatibility);
    • 0,34/0,5/0,75 = Wire gauge (mm²) for QO-type connectors.
  • Special Features/Certifications:
    • SH = Shielded (EMI/RFI protection);
    • M = Male gender (default if unspecified);
    • AU/VA/IB = Regional/industry certifications (AU=Australia, VA=voltage-compliant, IB=specialized industry);
    • PWR = Power-optimized (enhanced current handling);
    • CCL = Click-lock (tool-free quick assembly);
    • DUO = Dual-function (mixed signal/power transmission);
    • SKIN = Thin-profile (space-constrained installations);
    • XL = Extended length (for deep-cabinet wiring);
    • PB = Performance-optimized (enhanced durability).

IV. 3-Step Quick Selection Technique

Step 1: Determine Sub-series & Core Count

  • 5-core specialized needs (power/signal integration): Choose SACC-M12MSB series (e.g., 1424662/1507764) for 5-channel focused transmission.
  • 4/5-core versatile needs (mixed functions): Opt for SACC-M12MS series (e.g., 1513253/1641785) for diverse signal/power/coded requirements.
  • Core count matching: 2-core (low-power), 3-core (3-phase small power), 4-core (standard signal/power), 5-core (multi-channel integration).

Step 2: Select Function Type Based on Transmission Requirement

  • High-precision signal: Choose SC-type (e.g., 1513570/1513253) for sensor/data transmission.
  • Power delivery: Select PL-type (e.g., 1424662/1424666) for actuator/device power supply.
  • Protocol-coded signal (e.g., PROFINET): Pick QO-type (e.g., 1641785/1440753) with matching wire gauge.
  • Versatile wiring: Opt for CON-type (e.g., 1501540/1681088) for general signal/power connection.

Step 3: Match Installation & Certifications to Environment

  • Cable diameter:
    • Small cables (≤7mm): PG7 gland (e.g., 1681088/1553161);
    • Standard cables (7-9mm): PG9 gland (e.g., 1501540/1507764);
    • Large cables (9-11mm): PG11 gland (e.g., 1404415/1507052);
    • Variable diameters: DM range (e.g., DM 5-8 = 1440148/1440025).
  • High-interference environments: Select SH (shielded) variants (e.g., 1513570/1501540) to suppress EMI.
  • Regional compliance:
    • Australia: AU-certified (e.g., 1507764);
    • Regulatory-compliant projects: VA-certified (e.g., 1553187/1440753);
    • Specialized industries: IB-certified (e.g., 1424674).
  • Installation constraints:
    • Space-limited: SKIN thin-profile (e.g., 1556870);
    • Quick assembly: CCL click-lock (e.g., 1559767/1424699);
    • Mixed transmission: DUO dual-function (e.g., 1507052).

V. Recommended Industry-Scenario Combinations

Industry Typical Scenario Recommended Model Combination
Automotive Robotics 5-core actuator power + 4-core QO-coded encoder + 4-core shielded sensor 1424662 (M12MSB-5PL SH) + 1641785 (M12MS-4QO-0,75-M) + 1513253 (M12MS-4SC SH)
Industrial Ethernet (PROFINET) 4-core QO-coded PLC connection + 5-core shielded sensor array + PG7 miniature device 1440753 (M12MS-4QO-0,34-VA) + 1513570 (M12MSB-5SC SH) + 1681088 (M12MS-4CON-PG7)
Australian Mining Equipment AU-certified 5-core sensor + 4-core power + PG9 shielded connection 1507764 (M12MSB-5CON-PG9 SH AU) + 1424666 (M12MS-4PL SH) + 1501540 (M12MS-4CON-PG9 SH)
Compact Control Cabinets Thin-profile 4-core connection + click-lock 4-core power + PG7 small-cable signal 1556870 (M12MS-4CON-PG7-M SKIN) + 1424699 (M12MS-4PL SH CCL) + 1693416 (M12MS-5CON-PG7-SH)
High-Interference Manufacturing Shielded 4-core signal + 5-core dual-function + power-optimized PG11 connection 1513253 (M12MS-4SC SH) + 1507052 (M12MS-4CON-PG11-DUO-M) + 1421125 (M12MS-4CON-PG7-M PWR)

VI. Selection Pitfall Avoidance Guide

  1. Core Count Mismatch: 4-channel sensors using 5-core connectors → Select 4-core variants (e.g., 1513253/1641785) to avoid unused contacts and wiring inefficiency.
  2. Function Type Error: Power transmission using SC-type connectors → Choose PL-type (e.g., 1424662/1424666) for enhanced current handling and safety.
  3. Cable Gland Incompatibility: 8mm cables using PG7 glands → Match gland size to cable diameter (PG9 for 7-9mm, DM 5-8 for variable diameters) to ensure IP67 protection.
  4. Shielding Neglect: High-interference environments (inverters/motors) using non-SH connectors → Select SH variants (e.g., 1513570/1501540) to prevent signal distortion.
  5. Regional Certification Missing: Australian projects using non-AU connectors → Choose AU-certified variants (e.g., 1507764) to meet local regulatory requirements.
  6. Wire Gauge Mismatch: 0.75mm² cables using 0.34mm² QO connectors → Match QO-type wire gauge (e.g., 1641785 for 0.75mm²) to ensure reliable signal transmission.
  7. Special Feature Overlooking: Space-constrained installations using standard-profile connectors → Opt for SKIN thin-profile (e.g., 1556870) or XL extended-length (e.g., 1401096) variants.

Conclusion: Select the Right M12 Connector for Industrial Connectivity Excellence

The Phoenix SACC-M12MSB and SACC-M12MS series deliver versatile, industrial-grade M12 connectivity solutions for signal, power, and coded data transmission. With 2-5 core configurations, shielded protection, diverse installation options, and regional certifications, these connectors meet the demands of automation, robotics, and control systems.

Phoenix SACC-M12MSB/SACC-M12MS Series Industrial M12 Circular Connectors Selection Guide

Created on:2025-12-16 11:29

News Dynamics

NEWS