Phoenix PSM/PSI Series Industrial Fiber Optic & Communication Accessories Selection Guide
Opening: Comprehensive Solutions for Industrial Data Transmission & Fiber Optic Management
The Phoenix PSM/PSI series offers specialized industrial-grade tools, interface converters, and wireless modules for fiber optic installation, protocol conversion, and wireless communication. These products ensure reliable data transmission in harsh industrial environments while providing flexibility for system integration.
PSM Series: Focuses on fiber optic tools (cleaving, stripping, power measurement) and protocol conversion devices for RS232/RS485/RS422 to fiber optic conversion.
PSI Series: Features wireless interface modules (Bluetooth, PROFIBUS/BT), fieldbus repeaters, and active terminators for extending network range and improving signal integrity.
I. PSM Series: Fiber Optic Tools & Interface Solutions
1. Fiber Optic Installation & Testing Tools
| Part Number | Complete Model | Core Function | Key Features | Applications |
|---|---|---|---|---|
| 2708465 | PSM-HCS-KONFTOOL/B-FOC | HCS fiber configuration tool | B-FOC (ST) connector compatible; Includes stripping knife, cleaving tool, microscope, and two B-FOC connectors Phoenix Contact USA | Professional fiber optic installation in control cabinets; Industrial automation optical networks |
| 2799526 | PSM-HCS-KONFTOOL | Universal HCS fiber tool kit | No specific connector type; Comprehensive set for various HCS fiber terminations Phoenix Contact USA | General fiber optic maintenance; Multi-type fiber projects |
| 2744995 | PSM-HCS-CLEAVETOOL | Precision fiber cleaving tool | For PCF fibers; Creates perpendicular cuts for optimal fusion Phoenix Contact USA | High-precision fiber splicing; Industrial fiber optic network expansion |
| 2744199 | PSM-FO-STRIP | Fiber coating removal pliers | Specifically designed for polymer and PCF cables; Gentle stripping without damaging core Phoenix Contact USA | Preparing fiber for termination; Repairing fiber optic cables |
| 2744885 | PSM-FO-COATING-STRIP 0.3MM | Precise coating stripper | 0.3mm coating thickness compatibility; Single-action operation | Fine-coating fibers; Medical or precision industrial applications |
| 2799539 | PSM-FO-POWERMETER | Fiber optic power measurement kit | Includes power meter, F-SMA/B-FOC adapters, reference cables Phoenix Contact USA | Testing fiber link quality; Troubleshooting optical networks; Signal loss diagnostics |
2. Protocol Converters (RS232/RS485/RS422 ↔ Fiber Optic)
| Part Number | Complete Model | Conversion | Isolation | Key Features | Applications |
|---|---|---|---|---|---|
| 2761842 | PSM-EG-RS485W2/FO-E/G | RS485(2-wire) ↔ Fiber | Yes (RS485//supply) | B-FOC connector; Max 57.6kbps; Rail-mountable Phoenix Contact USA | Industrial automation; Process control; Long-distance signal transmission |
| 2761253 | PSM-EG-RS232/TTY-P/2K | RS232 ↔ TTY/RS422 | 2kV isolation | Terminal block connection; Serial device extension Phoenix Contact USA | Industrial serial communication; Legacy equipment integration |
| 2761392 | PSM-EG-RS232/RS485-P/2D | RS232 ↔ RS485(2-wire) | 3-way isolation | Electrical isolation between VCC, RS232, RS485; Rail-mountable Phoenix Contact USA | Converting PC/PLC RS232 to industrial RS485 bus; Modbus networks |
| 2761266 | PSM-EG-RS232/RS422-P/4K | RS232 ↔ RS422 | 4kV isolation | High isolation; Surge protection to DIN rail Phoenix Contact USA | High-voltage environments; Harsh industrial settings; Noise-sensitive applications |
| 2761444 | PSM-EG-RS232/RS232-P/4K | RS232 ↔ RS232 | 4kV isolation | Galvanic isolation; Signal conditioning; Rail-mountable Phoenix Contact USA | Protecting control systems from ground loops; Extending communication distance |
| 2744652 | PSM-CABLE-PROFIB/FC | PROFIBUS ↔ FC fiber | Built-in | Pre-terminated cable; FC connector; PROFIBUS compatibility Phoenix Contact USA | PROFIBUS network fiber extension; Factory automation backbone |
| 2708753 | PSM-AD-D9-NULLMODEM | RS232 null modem adapter | No | D9 connector; Cross-wired for direct PC-to-device connection Phoenix Contact USA | Debugging serial devices; Connecting two computers directly |
II. PSI Series: Wireless Communication & Fieldbus Solutions
1. Wireless Interface Modules (Bluetooth)
| Part Number | Complete Model | Interface | Key Features | Applications | |
|---|---|---|---|---|---|
| 2313795 | PSI-WL-RS232-RS485/BT/HL | RS232/RS485 ↔ Bluetooth | UL-HazLoc certification; MCX antenna port; Path diagnostics Phoenix Contact USA | Hazardous industrial environments; Mobile equipment monitoring; Remote diagnostics | |
| 2313805 | PSI-WL-RS232-RS485/BT/2DO | RS232/RS485 ↔ Bluetooth | Two digital outputs; Range up to 150m; Frequency hopping Phoenix Contact USA | Machine control; Condition monitoring; Remote actuation | |
| 2708517 | PSI-WL-RS232-RS485/BT | RS232/RS485 ↔ Bluetooth | DIN rail mount; Simple configuration; 2.4GHz ISM band Phoenix Contact USA | General industrial wireless connectivity; Equipment monitoring; Mobile maintenance | |
| 2313876 | PSI-WL-PROFIB/BT-SET/2DO | PROFIBUS ↔ Bluetooth | Two digital outputs; Pre-configured; Includes antenna | PROFIBUS network wireless extension; Plant-wide monitoring; Mobile operator interface | |
| 2313313 | PSI-WL-PROFIB/BT-SET | PROFIBUS ↔ Bluetooth | Complete set; Plug-and-play; Diagnostic LEDs Phoenix Contact USA | Wireless PROFIBUS access for programming; Machine-to-machine communication; Remote troubleshooting | |
| 2702636 | PSI-TERMINATOR-PB-TBUS | PROFIBUS active terminator | Yes (supply/data) | Redundant power; Programming interface; Bus disconnect Phoenix Contact USA | PROFIBUS network end termination; Improving signal integrity; System maintenance |
| 2313944 | PSI-TERMINATOR-PB | RS485/PROFIBUS terminator | Yes | Compact design; Isolated power; Bus diagnostic Phoenix Contact USA | General RS485/PROFIBUS network termination; Reducing signal reflections |
2. Fieldbus Repeaters & Extenders
| Part Number | Complete Model | Protocol | Extension | Isolation | Applications |
|---|---|---|---|---|---|
| 2313096 | PSI-REP-RS485W2 | RS485(2-wire) | Distance ×2 | 3-way | Extending RS485 networks; Multi-drop systems; Industrial Ethernet integration |
| 2708863 | PSI-REP-PROFIBUS/12MB | PROFIBUS | Distance ×2 | 4-way | PROFIBUS network expansion; 12Mbps high-speed operation; Isolating network segments Phoenix Contact USA |
| 2313423 | PSI-REP-DNET CAN | DeviceNet/CAN | Distance ×2 | 4-way | Industrial automation with DeviceNet; CAN bus isolation; Machine-to-machine communication Phoenix Contact USA |
| 2313737 | PSI-REP-CNET | Controller Area Network | Distance ×2 | 4-way | Controller network extension; Automotive manufacturing; Process control systems Phoenix Contact USA |
| 2313148 | PSI-MPI/RS232-PC | MPI ↔ RS232 | Protocol conversion | Yes | Programming Siemens PLCs; MPI network access from PC; Industrial automation maintenance Phoenix Contact USA |
III. Product Nomenclature Decoding
PSM Series Naming Convention:
PSM-[Function]-[Interface]-[Specs]/[Connector]
- PSM: Phoenix Sensor Module (fiber optic tools and interface converters)
- Function:
- HCS-KONFTOOL: HCS fiber configuration tool
- FO-STRIP: Fiber coating stripper
- FO-POWERMETER: Fiber optic power meter
- EG: Electrical-to-optical converter
- AD: Adapter
- CABLE: Pre-terminated cable
- Interface:
- RS232/RS485/RS422: Serial protocol
- TTY: Teletypewriter interface
- PB: PROFIBUS
- FC: Fiber optic connector type
- Specs:
- 2K/4K: Isolation level (kV)
- 2D: 2-directional conversion
- W2: 2-wire interface
- P: Plug/terminal block connection
- Connector:
- B-FOC: ST-type fiber connector
- FC: Ferrule connector
- D9: 9-pin D-sub connector
PSI Series Naming Convention:
PSI-[Function]-[Interface]-[Specs]/[Feature]
- PSI: Phoenix System Interface (wireless modules, terminators, repeaters)
- Function:
- WL: Wireless interface (Bluetooth)
- TERMINATOR: Active bus terminator
- REP: Repeater/extender
- MPI: Siemens MPI interface
- Interface:
- RS232/RS485: Serial protocol
- PB: PROFIBUS
- DNET: DeviceNet
- CAN: Controller Area Network
- Specs:
- BT: Bluetooth wireless
- 2DO: Two digital outputs
- HL: Hazardous location certified
- 12MB: 12Mbps data rate
- Feature:
- SET: Complete set (includes antenna, cables)
- TBUS: Terminal bus (for PROFIBUS)
IV. 3-Step Selection Guide
Step 1: Determine Application Category
- Fiber Optic Installation: Choose PSM-HCS-KONFTOOL, PSM-HCS-CLEAVETOOL, PSM-FO-STRIP, or PSM-FO-POWERMETER for fiber preparation and testing
- Protocol Conversion: Select PSM-EG series for RS232/RS485/RS422 ↔ fiber optic conversion
- Wireless Communication: Opt for PSI-WL series for Bluetooth connectivity between serial devices
- Fieldbus Enhancement: Use PSI-TERMINATOR or PSI-REP series for network termination and extension
Step 2: Match Interface Requirements
- Fiber Optic: Verify connector type (B-FOC/ST, FC, SC-RJ)
- Serial Interface: Confirm RS232, RS485(2/4-wire), or RS422
- Power Supply: Check voltage requirements (24V DC typical)
- Isolation: High-noise environments need 4kV isolation (e.g., PSM-EG-RS232/RS422-P/4K)
Step 3: Select Additional Features Based on Environment
- Hazardous Areas: Choose UL-HazLoc certified models (e.g., PSI-WL-RS232-RS485/BT/HL)
- Space Constraints: Compact DIN rail modules (all PSM/PSI series) save cabinet space
- Extended Range: Use repeaters (PSI-REP) to double network distance
- Diagnostics: Select models with built-in signal monitoring (e.g., PSI-WL with bargraph)
V. Industry Application Combinations
| Industry | Scenario | Recommended Products | Benefits |
|---|---|---|---|
| Process Automation | Plant-wide monitoring with fiber optic backhaul | PSM-HCS-KONFTOOL/B-FOC + PSM-EG-RS485W2/FO-E/G + PSI-TERMINATOR-PB | High-speed, noise-free data transmission; Signal integrity; Easy maintenance |
| Factory Automation | Wireless programming and diagnostics | PSI-WL-RS232-RS485/BT/2DO + PSI-REP-PROFIBUS/12MB | Mobile access to control systems; Reduced downtime; Remote troubleshooting |
| Power Generation | High-voltage environment monitoring | PSM-EG-RS232/RS422-P/4K + PSI-TERMINATOR-PB-TBUS | Electrical isolation; Surge protection; System stability in harsh conditions |
| Oil & Gas (Hazardous) | Monitoring in explosive environments | PSI-WL-RS232-RS485/BT/HL + PSI-REP-DNET CAN | Safe operation in hazardous areas; Wireless data transmission; Equipment diagnostics |
| Smart Buildings | Multi-system integration | PSM-EG-RS232/RS485-P/2D + PSI-TERMINATOR-PB + PSM-FO-POWERMETER | Centralized control; Protocol conversion; Network optimization |
VI. Selection Pitfalls to Avoid
- Mismatched Interfaces: Using B-FOC connectors with SC-RJ equipment → Verify fiber optic connector types before purchase
- Insufficient Isolation: Standard isolation in high-noise environments → Choose 4kV isolation models (e.g., PSM-EG-RS232/RS422-P/4K)
- Range Limitations: Underestimating required transmission distance → Use repeaters (PSI-REP) to extend network reach
- Hazardous Environment Neglect: Using standard modules in explosive areas → Always select UL-HazLoc certified variants (e.g., PSI-WL-RS232-RS485/BT/HL)
- Power Supply Issues: Ignoring voltage requirements → Confirm 24V DC compatibility for all modules
- Fiber Coating Thickness: Using incorrect stripper for fiber coatings → Match stripper to coating thickness (e.g., 0.3mm for PSM-FO-COATING-STRIP 0.3MM)
Conclusion: Complete Your Industrial Network with PSM/PSI Solutions
The Phoenix PSM/PSI series provides indispensable tools and interfaces for modern industrial communication infrastructure. From fiber optic installation and protocol conversion to wireless connectivity and fieldbus optimization, these products ensure reliable data transmission in challenging environments.