Phoenix SACB Series Industrial Pre-Assembled Cables (Multi-Core/Multi-Gauge & Standard Configurations) Selection Guide
Opening: Versatile Signal+Power Integration & Targeted Industrial Connectivity
The Phoenix SACB series expands its industrial cable lineup with multi-core multi-gauge mixed cables and standard core/pole pre-assembled cables, engineered for seamless integration of signal transmission and power distribution in automation systems. Covering three core configurations—multi-gauge mixed (6X0.34/2X0.75, 4X0.34/3X0.75), 6/3 (6-core 3-pole), 4/4 (4-core 4-pole), and 4/3 (4-core 3-pole)—these cables feature industrial-grade PUR jackets, heavy-duty (HD) reinforcement, PROFINET QO coding, point-to-point (PTP) connectivity, and flexible interface conversions (M8/M12/M16). Designed for sensor/actuator networks, PLC I/O expansion, and mixed signal-power integration, they deliver robust performance in harsh industrial environments (oil resistance, -40°C to +85°C operating range) and plug-and-play installation for efficiency.
I. Core Advantages of the Series
-
Dual Configuration Categories for Targeted Needs
- Multi-Core Multi-Gauge Mixed Cables: Combines fine-gauge (0.34mm²) signal cores and thick-gauge (0.75mm²) power cores in one cable, eliminating separate wiring for signal and power (e.g., 6X0.34/2X0.75 = 6 signal + 2 power cores);
- Standard Core/Pole Cables: 6/3 (6-core 3-pole), 4/4 (4-core 4-pole), 4/3 (4-core 3-pole) configurations for dedicated signal/power transmission, with interface compatibility (M8/M12/M16) for diverse industrial devices.
-
Industrial-Grade Durability & Environmental Resilience
- PUR Jacket: Oil, abrasion, and chemical resistance, ideal for factory floors and harsh process environments;
- Heavy-Duty (HD) Variants: Reinforced construction for vibration resistance (e.g., drag chains, mobile machinery) and extended service life;
- Wide Temperature Range: -40°C to +85°C, suitable for extreme indoor/outdoor industrial settings;
- Signal Integrity: Shielded design (implied in HD/QO variants) suppresses EMI/RFI interference from motors and inverters.
-
Specialized Functionality & Protocol Compliance
- PROFINET QO Coding: 4/4-C QO-0.34 variant for seamless industrial Ethernet integration (error-free mating);
- Point-to-Point (PTP): Dedicated PTP variants for direct device-to-device connections (e.g., sensor-to-PLC);
- Interface Versatility: M8 (compact sensors), M12 (industrial Ethernet), M16 (medium-duty equipment) for universal compatibility;
- Mixed Signal-Power: Multi-gauge variants reduce wiring complexity by combining signal and power in one cable.
-
Easy Installation & Flexibility
- Pre-terminated, factory-assembled design eliminates on-site crimping/wiring errors and reduces installation time;
- Length options (5m/10m/50m) for short-distance (cabinet-internal) to long-distance (cross-plant) wiring;
- Tool-free twist-lock mechanisms for secure, quick connections;
- Compatible with Phoenix and third-party industrial control equipment (PLCs, sensors, actuators).
II. Product Classification & Detailed Parameter Table
The series is categorized by configuration type (Multi-Gauge Mixed Cables, Standard Core/Pole Cables) with sub-variants based on core count, interface, length, and special features.
1. Multi-Core Multi-Gauge Mixed Cables (Signal + Power Integration)
Ideal for reducing wiring complexity by combining fine-gauge signal cores and thick-gauge power cores.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 1517589 | SACB-6X0.34/2X0.75-50 | Core/Gauge:6×0.34mm² (signal) + 2×0.75mm² (power); Length:50m; Jacket:Industrial-grade polymer | 6-signal + 2-power core integration | Long-distance (50m) sensor networks requiring combined signal/power (e.g., cross-plant monitoring) |
| 1503331 | SACB-6X0.34/3X0.75-50.0 PUR | Core/Gauge:6×0.34mm² (signal) + 3×0.75mm² (power); Length:50m; Jacket:PUR | 6-signal + 3-power core with PUR oil resistance | 50m harsh-environment sensor/actuator wiring (e.g., chemical plant multi-sensor arrays) |
| 1503328 | SACB-4X0.34/3X0.75-50.0 PUR | Core/Gauge:4×0.34mm² (signal) + 3×0.75mm² (power); Length:50m; Jacket:PUR | 4-signal + 3-power core with PUR protection | 50m medium-density signal/power integration (e.g., factory automation production lines) |
2. Standard Core/Pole Cables (Dedicated Signal/Power)
2.1 6/3 Series (6-Core 3-Pole)
For 6-channel signal transmission with 3-pole power delivery, ideal for medium-scale sensor networks.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 1516195 | SACB-6/3-L-M16-M8 | Core/Pole:6/3; Type:L (long-distance); Interface:M16→M8; Jacket:Standard industrial polymer | 6-core M16-to-M8 signal/power | Medium-distance (up to 10m) M16-to-M8 sensor wiring (e.g., control cabinet to M8 sensors) |
| 1197408 | SACB-6/3-L-M12-M8 HD | Core/Pole:6/3; Type:L; Interface:M12→M8; Feature:HD (heavy-duty); Jacket:PUR | 6-core heavy-duty M12-to-M8 wiring | Vibration-prone 6-channel sensor networks (e.g., automotive assembly line) |
| 1197231 | SACB-6/3-L-10,0PUR-M8 HD | Core/Pole:6/3; Length:10m; Jacket:PUR; Interface:→M8; Feature:HD | 10m heavy-duty M8 wiring with PUR oil resistance | 10m harsh-environment 6-channel sensor/actuator connections |
| 1516043 | SACB-6/3-L-10,0PUR-M8 | Core/Pole:6/3; Length:10m; Jacket:PUR; Interface:→M8 | 10m standard M8 wiring with PUR protection | 10m medium-distance 6-channel sensor networks (e.g., food & beverage manufacturing) |
| 1197216 | SACB-6/3-L-5,0PUR-M8 HD | Core/Pole:6/3; Length:5m; Jacket:PUR; Interface:→M8; Feature:HD | 5m heavy-duty M8 wiring with PUR oil resistance | 5m compact 6-channel sensor/actuator wiring (e.g., machine-internal networks) |
2.2 4/4 Series (4-Core 4-Pole)
For 4-channel balanced signal/power integration, ideal for compact automation systems.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| 1548419 | SACB-4/4-C QO-0.34 | Core/Pole:4/4; Type:C (compact); Coding:QO (PROFINET); Wire Gauge:0.34mm²; Jacket:Standard | 4-core PROFINET-coded signal/power | PROFINET-compliant 4-channel sensor/PLC wiring (e.g., industrial Ethernet networks) |
2.3 4/3 Series (4-Core 3-Pole)
For 4-channel signal transmission with 3-pole power delivery, ideal for small-scale sensor arrays.
| Part Number | Complete Model | Core Parameters | Key Features | Application Scenario |
|---|---|---|---|---|
| Point-to-Point (PTP) | 1197604 | SACB-4/3-L-PTP-M8 HD | Core/Pole:4/3; Type:L; Interface:PTP→M8; Feature:HD | 4-channel PTP heavy-duty M8 wiring (e.g., dedicated sensor-to-PLC links) |
| M16-M8 Interface | 1197406 | SACB-4/3-L-M16-M8 HD | Core/Pole:4/3; Type:L; Interface:M16→M8; Feature:HD | 4-channel heavy-duty M16-to-M8 wiring (e.g., control cabinet to M8 sensors) |
| 1516182 | SACB-4/3-L-M16-M | Core/Pole:4/3; Type:L; Interface:M16→M (standard); Jacket:Standard | 4-channel standard M16-to-M wiring (e.g., medium-duty equipment integration) | |
| M12-M8 Interface | 1197405 | SACB-4/3-L-M12-M8 | Core/Pole:4/3; Type:L; Interface:M12→M8; Jacket:Standard | 4-channel standard M12-to-M8 wiring (e.g., industrial Ethernet sensor networks) |
| 1516234 | SACB-4/3-L-M12-M8 | Core/Pole:4/3; Type:L; Interface:M12→M8; Jacket:Standard | 4-channel standard M12-to-M8 wiring (e.g., PLC-to-M8 sensor connections) | |
| Coded M8 Interface | 1197599 | SACB-4/3-L-C-M8 HD GG | Core/Pole:4/3; Type:L; Interface:C→M8; Feature:HD + GG (special coding); Jacket:PUR | 4-channel coded heavy-duty M8 wiring (e.g., high-vibration sensor arrays) |
| PUR Jacket (10m) | 1197212 | SACB-4/3-L-10,0PUR-M8 HD | Core/Pole:4/3; Length:10m; Jacket:PUR; Interface:→M8; Feature:HD | 10m heavy-duty M8 wiring with PUR oil resistance (e.g., long-distance sensor networks) |
| PUR Jacket (5m) | 1197207 | SACB-4/3-L-5,0PUR-M8 HD | Core/Pole:4/3; Length:5m; Jacket:PUR; Interface:→M8; Feature:HD | 5m heavy-duty M8 wiring with PUR protection (e.g., compact automation systems) |
III. Nomenclature Decoding: Understanding the Part Number System
SACB-[Configuration]-[Type]-[Length]-[Interface/Coding]-[Suffixes]
- SACB: Product series identifier (industrial pre-assembled cables);
- Configuration:
- Multi-Gauge: [Signal Cores×Gauge]/[Power Cores×Gauge] (e.g., 6X0.34/2X0.75 = 6×0.34mm² signal + 2×0.75mm² power);
- Standard Core/Pole: [Core Count]/[Pole Count] (e.g., 6/3 = 6 cores, 3 poles; 4/4 = 4 cores, 4 poles);
- Type:
- L = Long-distance optimized (for extended wiring);
- C = Compact (for space-constrained applications);
- Length: Specified in meters (e.g., 5,0 = 5m, 10,0 = 10m, 50 = 50m); "PUR" indicates polyurethane jacket;
- Interface/Coding:
- Interfaces: M8/M12/M16 (connector types); PTP (point-to-point);
- Coding: QO (PROFINET coding); GG (special coding);
- Suffixes:
- HD = Heavy-duty (reinforced for vibration/mechanical stress);
- PUR = Polyurethane jacket (oil/chemical resistance);
- 0.34/0.75 = Wire gauge (mm²) for signal/power cores;
- M = Standard mating compatibility.
IV. 3-Step Quick Selection Technique
Step 1: Select Configuration Type Based on Wiring Needs
- Mixed Signal+Power Integration: Choose multi-gauge mixed cables (e.g., 1503331/1503328) to combine signal and power in one cable, reducing complexity.
- Dedicated Signal/Power: Opt for standard core/pole cables:
- 6-channel signal + 3-pole power: 6/3 series (e.g., 1197408/1516043);
- 4-channel balanced signal/power: 4/4 series (1548419 for PROFINET);
- 4-channel signal + 3-pole power: 4/3 series (e.g., 1197604/1516234).
Step 2: Match Interface & Length to Devices/Installation
- Interface Selection:
- Compact sensors (M8): All M8-terminated variants (e.g., 1197231/1197207);
- Industrial Ethernet (M12): M12-M8 variants (1197408/1197405);
- Medium-duty equipment (M16): M16-M8 variants (1516195/1197406);
- Direct device-to-device: PTP variants (1197604);
- Length:
- Short-distance (5m): 5,0PUR variants (1197216/1197207);
- Medium-distance (10m): 10,0PUR variants (1197231/1516043);
- Long-distance (50m): Multi-gauge 50m variants (1517589/1503331).
Step 3: Choose Special Features for Environment/Protocol
- Harsh Environments: HD (heavy-duty) + PUR jacket (e.g., 1197231/1197207) for vibration/oil resistance.
- PROFINET Integration: 4/4-C QO-0.34 (1548419) for QO-coded industrial Ethernet.
- High-Interference Settings: HD variants (implied shielding) or QO-coded variants for signal integrity.
- Special Coding: GG suffix (1197599) for error-free mating in custom sensor networks.
V. Recommended Industry-Scenario Combinations
| Industry | Typical Scenario | Recommended Model Combination |
|---|---|---|
| Automotive Assembly Line (High-Vibration) | 6/3 HD M12-M8 + 4/3 PTP M8 HD + 50m multi-gauge mixed signal/power | 1197408 (SACB-6/3-L-M12-M8 HD) + 1197604 (SACB-4/3-L-PTP-M8 HD) + 1503331 (SACB-6X0.34/3X0.75-50.0 PUR) |
| PROFINET Industrial Ethernet | 4/4 QO-coded + 6/3 10m PUR M8 + 4/3 M12-M8 standard | 1548419 (SACB-4/4-C QO-0.34) + 1516043 (SACB-6/3-L-10,0PUR-M8) + 1516234 (SACB-4/3-L-M12-M8) |
| Chemical Plant (Oil-Resistant) | 50m multi-gauge mixed + 6/3 5m HD PUR + 4/3 10m HD PUR | 1503328 (SACB-4X0.34/3X0.75-50.0 PUR) + 1197216 (SACB-6/3-L-5,0PUR-M8 HD) + 1197212 (SACB-4/3-L-10,0PUR-M8 HD) |
| Compact Automation (Space-Constrained) | 4/4 QO-coded + 4/3 M16-M8 + 6/3 5m HD | 1548419 (SACB-4/4-C QO-0.34) + 1516182 (SACB-4/3-L-M16-M) + 1197216 (SACB-6/3-L-5,0PUR-M8 HD) |
| Long-Distance Sensor Networks (50m) | 50m 6X0.34/2X0.75 + 50m 4X0.34/3X0.75 + 6/3 10m HD | 1517589 (SACB-6X0.34/2X0.75-50) + 1503328 (SACB-4X0.34/3X0.75-50.0 PUR) + 1197231 (SACB-6/3-L-10,0PUR-M8 HD) |
VI. Selection Pitfall Avoidance Guide
- Configuration Mismatch: 6-channel sensors using 4/3 series → Select 6/3 series (e.g., 1197408) for sufficient signal channels.
- Mixed Signal-Power Need Using Single-Gauge Cables: Combining signal and power with standard cables → Choose multi-gauge variants (1503331/1503328) to reduce wiring complexity.
- PROFINET Neglect: Industrial Ethernet projects using non-QO variants → Select 4/4-C QO-0.34 (1548419) for protocol compliance.
- Harsh Environment Using Standard Cables: Vibration/oil exposure using non-HD/PUR cables → Opt for HD+PUR variants (1197231/1197207) for durability.
- Interface Incompatibility: M12 controllers using M16-M8 cables → Match interface (e.g., 1197405 for M12-M8) to ensure physical mating.
- Length Overestimation/Underestimation: 10m required distance using 50m cables → Choose appropriate length (e.g., 1516043 for 10m) to avoid excess cable or tension.
- Signal Interference: High-noise environments using non-HD variants → Select HD variants (implied shielding) or QO-coded cables (1548419) for EMI suppression.
- Coding Mismatch: Custom sensor networks using non-GG variants → Choose GG suffix (1197599) for error-free mating.
Conclusion: Select the Right SACB Cable for Mixed Signal-Power & Targeted Industrial Connectivity
The Phoenix SACB series delivers versatile pre-assembled cable solutions for mixed signal-power integration and dedicated industrial connectivity. With multi-gauge mixed configurations (reducing wiring complexity) and standard core/pole variants (for targeted applications), combined with HD reinforcement, PUR oil resistance, and PROFINET compliance, these cables adapt to harsh environments, regulatory requirements, and space constraints across industries.