Phoenix PSI Series Industrial Communication Auxiliary Products Selection Guide

Opening: Reliable Communication Support for Industrial IoT & Remote Data Transmission

The Phoenix PSI series represents industrial-grade communication auxiliary products engineered to enable stable remote data transmission, signal enhancement, and device connectivity in industrial IoT (IIoT) and automation systems. Covering three core product categories—GSM/UMTS communication antennas, multi-protocol modems (GPRS/GSM/DATA/FAX), and dedicated communication cables—these products support diverse communication protocols (GSM/GPRS/UMTS) and interface standards (RS232/USB), with flexible length options and ruggedized designs. Designed for remote monitoring, industrial telemetry, and field device communication, the PSI series delivers industrial-grade reliability (wide temperature range, anti-interference, durable construction) and seamless integration with Phoenix and third-party industrial equipment.


I. Core Advantages of the Series

  1. Comprehensive Communication Support

    • Antennas: Dual-band (GSM/UMTS) and single-band (GSM) options for signal enhancement, with specialized form factors (Stub/QB) for different installation scenarios;
    • Modems: Multi-functional variants (GPRS/GSM, DATA/FAX, DATA/BASIC) supporting data transmission, fax communication, and basic serial communication;
    • Cables: Dedicated GSM/UMTS extension cables (5m/10m) and USB data cables (1m) for device connectivity and signal extension.
  2. Industrial-Grade Reliability & Durability

    • Wide operating temperature range (-40°C to +85°C), suitable for extreme field environments (outdoor cabinets, remote sites);
    • Anti-interference design: Antennas with optimized signal reception, modems with EMC compliance (IEC 61000-6-2/4) for industrial noise immunity;
    • Durable construction: Weather-resistant antennas (suitable for outdoor deployment), abrasion-resistant cables with industrial-grade jackets;
    • Long service life: ≥10⁵ operating hours for modems, corrosion-resistant antenna connectors.
  3. Flexible Compatibility & Easy Integration

    • Protocol support: GSM/GPRS/UMTS (2G/3G) for global cellular communication, RS232/USB for serial/USB device connectivity;
    • Interface versatility: RS232 (for legacy industrial devices), USB A/Mini B (for modern controllers/PCs);
    • Plug-and-play operation: Modems with standard serial/USB interfaces, antennas with quick-connect connectors, cables with pre-terminated ends;
    • Compact design: Space-saving modems and antennas for control cabinet or field installation.
  4. Targeted Design for Industrial Scenarios

    • Antenna form factors: Stub-type (compact, for indoor/cabinet use) and QB-type (omnidirectional, for outdoor/long-range signal reception);
    • Cable length options: 1m (desktop/control cabinet), 5m/10m (field device extension);
    • Modem functionality: Basic data transmission, fax support, and GPRS/GSM cellular communication for remote data backhaul.

II. Product Classification & Detailed Parameter Table

The series is categorized by functional type (Communication Antennas, Modems, Communication Cables) with sub-variants based on protocol, interface, length, and form factor.

1. Communication Antennas (Signal Enhancement)

For boosting GSM/GPRS/UMTS signal reception/transmission in industrial communication systems.

Part Number Complete Model Core Parameters Key Features Application Scenario
2313342 PSI-GSM-STUB-ANT Type:GSM Antenna; Form Factor:Stub (compact); Frequency:GSM 850/900/1800/1900MHz; Connector:Quick-connect Compact GSM signal enhancement Indoor control cabinets, short-range GSM communication (e.g., local remote monitoring)
2313371 PSI-GSM/UMTS-QB-ANT Type:GSM/UMTS Dual-Band Antenna; Form Factor:QB (omnidirectional); Frequency:GSM 850/900/1800/1900MHz + UMTS 850/900/1900/2100MHz; Connector:Quick-connect Dual-band (2G/3G) omnidirectional signal enhancement Outdoor remote sites, long-range cellular communication (e.g., field sensor data backhaul)

2. Modems (Data/Fax/Cellular Communication)

For data transmission, fax communication, and cellular (GPRS/GSM) remote connectivity.

Part Number Complete Model Core Parameters Key Features Application Scenario
Cellular Modem (GPRS/GSM) 2313106 PSI-GPRS/GSM-MODEM/RS232-QB Type:GPRS/GSM Modem; Interface:RS232; Protocol:GPRS/GSM (2G); Compatibility:QB Antenna; Function:Data transmission Remote cellular data backhaul (e.g., oil & gas pipeline monitoring, agricultural sensor networks)
Data/Fax Modem 2708253 PSI-DATA/FAX-MODEM/SE T1 Type:Data/Fax Modem; Interface:SE T1; Protocol:Analog Data/Fax; Function:Data transmission + fax communication Industrial fax communication + data transfer (e.g., process plant documentation transmission)
  2708203 PSI-DATA/FAX-MODEM/RS232 Type:Data/Fax Modem; Interface:RS232; Protocol:Analog Data/Fax; Function:Data transmission + fax communication Legacy industrial device data/fax transmission (e.g., old PLC data backup via fax)
Basic Data Modem 2313067 PSI-DATA/BASIC-MODEM/RS232 Type:Basic Data Modem; Interface:RS232; Protocol:Analog Data; Function:Basic serial data transmission Simple industrial serial data communication (e.g., control cabinet device-to-device data transfer)

3. Communication Cables (Device Connectivity & Signal Extension)

Dedicated cables for connecting modems, antennas, and industrial devices.

Part Number Complete Model Core Parameters Key Features Application Scenario
USB Data Cable 2313575 PSI-CA-USB A/MINI B/1METER Type:USB Data Cable; Interface:USB A (host) → USB Mini B (device); Length:1m; Jacket:Industrial-grade polymer Connect modems/industrial devices to PCs/controllers (e.g., modem programming, data logging)
GSM/UMTS Extension Cable 2900981 PSI-CAB-GSM/UMTS-10M Type:GSM/UMTS Antenna Extension Cable; Length:10m; Jacket:Abrasion-resistant; Connector:Antenna-compatible quick-connect 10m antenna extension for outdoor deployment (e.g., remote site antenna placement)
  2900980 PSI-CAB-GSM/UMTS-5M Type:GSM/UMTS Antenna Extension Cable; Length:5m; Jacket:Abrasion-resistant; Connector:Antenna-compatible quick-connect 5m antenna extension for medium-distance deployment (e.g., control cabinet to roof-mounted antenna)

III. Nomenclature Decoding: Understanding the Part Number System

PSI-[Product Type]-[Protocol/Interface]-[Form Factor/Length]-[Suffix]

  • PSI: Product series identifier (industrial communication auxiliary products);
  • Product Type:
    • GSM/UMTS/GPRS = Communication protocol (cellular);
    • DATA/FAX/BASIC = Modem functionality;
    • CA/CAB = Cable (CA=USB cable, CAB=extension cable);
    • ANT = Antenna;
  • Protocol/Interface:
    • GSM/UMTS/GPRS = Cellular communication protocols;
    • DATA/FAX = Modem communication type;
    • RS232/SE T1 = Serial interfaces;
    • USB A/MINI B = USB interface types;
  • Form Factor/Length:
    • STUB/QB = Antenna form factors (Stub=compact, QB=omnidirectional);
    • 1METER/5M/10M = Cable length (1m/5m/10m);
  • Suffix:
    • ANT = Antenna;
    • MODEM = Modem;
    • CA = Cable (USB);
    • CAB = Cable (extension);
    • QB = Compatible with QB-type antennas (for modems).

IV. 3-Step Quick Selection Technique

Step 1: Select Product Type Based on Communication Needs

  • Signal Enhancement: Choose Communication Antennas (e.g., 2313342/2313371) to boost GSM/UMTS signal strength.
  • Data/Fax/Cellular Transmission: Opt for Modems (e.g., 2313106/2708203) for data transfer, fax, or remote cellular connectivity.
  • Device Connectivity/Extension: Pick Communication Cables (e.g., 2313575/2900980) for connecting modems, antennas, or industrial devices.

Step 2: Match Protocol/Interface to System Requirements

  • Cellular Communication (GSM/GPRS/UMTS):
    • Antenna: 2313371 (dual-band GSM/UMTS) for 2G/3G, 2313342 (GSM) for single-band;
    • Modem: 2313106 (GPRS/GSM) for cellular data backhaul;
    • Cable: 2900980/2900981 (GSM/UMTS extension) for antenna placement;
  • Serial Data/Fax:
    • Modem: 2708203 (RS232 Data/Fax) for legacy devices, 2313067 (RS232 Basic Data) for simple data transfer;
    • 2708253 (SE T1 Data/Fax) for specialized SE T1 interface;
  • USB Connectivity: Cable 2313575 (USB A/Mini B) for modern controllers/PCs.

Step 3: Choose Form Factor/Length for Installation

  • Antennas:
    • Indoor/Compact Cabinets: Stub-type (2313342) for space-saving installation;
    • Outdoor/Long-Range: QB-type (2313371) for omnidirectional signal reception;
  • Cables:
    • Control Cabinet/Desktop: 1m USB cable (2313575) for short-distance connections;
    • Medium-Distance (5m): 2900980 (GSM/UMTS) for antenna extension in workshops;
    • Long-Distance (10m): 2900981 (GSM/UMTS) for remote antenna placement (e.g., roof-mounted);
  • Modems:
    • RS232 Interface: 2313106/2708203/2313067 for legacy industrial devices;
    • SE T1 Interface: 2708253 for specialized system integration.

V. Recommended Industry-Scenario Combinations

Industry Typical Scenario Recommended Model Combination
Remote Industrial Monitoring (Cellular) GSM/UMTS dual-band antenna + GPRS/GSM modem + 10m extension cable + USB programming cable 2313371 (PSI-GSM/UMTS-QB-ANT) + 2313106 (PSI-GPRS/GSM-MODEM/RS232-QB) + 2900981 (PSI-CAB-GSM/UMTS-10M) + 2313575 (PSI-CA-USB A/MINI B/1METER)
Legacy Industrial Data/Fax RS232 Data/Fax modem + GSM stub antenna + 5m extension cable 2708203 (PSI-DATA/FAX-MODEM/RS232) + 2313342 (PSI-GSM-STUB-ANT) + 2900980 (PSI-CAB-GSM/UMTS-5M)
Control Cabinet Serial Communication Basic RS232 data modem + USB programming cable + compact stub antenna 2313067 (PSI-DATA/BASIC-MODEM/RS232) + 2313575 (PSI-CA-USB A/MINI B/1METER) + 2313342 (PSI-GSM-STUB-ANT)
Outdoor Remote Sensor Networks QB-type dual-band antenna + 10m extension cable + GPRS/GSM modem 2313371 (PSI-GSM/UMTS-QB-ANT) + 2900981 (PSI-CAB-GSM/UMTS-10M) + 2313106 (PSI-GPRS/GSM-MODEM/RS232-QB)
Specialized SE T1 Data/Fax SE T1 Data/Fax modem + GSM stub antenna + 5m extension cable 2708253 (PSI-DATA/FAX-MODEM/SE T1) + 2313342 (PSI-GSM-STUB-ANT) + 2900980 (PSI-CAB-GSM/UMTS-5M)

VI. Selection Pitfall Avoidance Guide

  1. Protocol Mismatch: 3G (UMTS) devices using GSM single-band antenna → Choose dual-band antenna (2313371) for GSM/UMTS compatibility.
  2. Interface Incompatibility: USB controllers using RS232-only modem → Select USB cable (2313575) or RS232-to-USB adapter for connectivity.
  3. Antenna Form Factor Mismatch: Outdoor deployment using stub-type antenna → Opt for QB-type (2313371) for omnidirectional signal reception.
  4. Cable Length Underestimation: 8m antenna extension using 5m cable → Choose 10m variant (2900981) to avoid signal loss from stretched cables.
  5. Functionality Neglect: Fax communication needs using basic data modem → Select Data/Fax modem (2708203/2708253) for fax support.
  6. Industrial Environment Neglect: Outdoor use using non-weather-resistant antenna → All PSI antennas are weather-resistant; QB-type (2313371) is optimized for outdoor deployment.
  7. Modem-Antenna Compatibility: QB antenna using non-QB-compatible modem → Ensure modem has QB suffix (2313106) for QB antenna compatibility.
  8. EMI Interference: High-noise environments using unshielded cables → PSI cables feature industrial-grade shielding for EMI suppression.

Conclusion: Select the Right PSI Product for Stable Industrial Communication

The Phoenix PSI series delivers targeted communication auxiliary solutions for industrial IoT, remote monitoring, and legacy device integration. With signal-enhancing antennas, multi-functional modems, and durable cables, these products ensure stable data transmission, flexible connectivity, and reliable performance in harsh industrial environments.

Phoenix PSI Series Industrial Communication Auxiliary Products Selection Guide

Created on:2025-12-23 10:23

News Dynamics

NEWS