Phoenix UM Series Industrial Interface & IO Modules Complete Selection Guide
I. Series Overview: Industrial-Grade IO Conversion & Interface Adaptation Solutions for Automation Control Systems
The Phoenix UM series is a full portfolio of industrial-grade interface modules, IO signal conversion modules, protocol adaptation modules and interface transfer modules engineered for signal acquisition, digital-analog conversion, IO expansion and protocol docking in factory automation, DCS/PLC control systems and industrial equipment interconnection scenarios. This series covers core product lines including UM-IC50 (large-spec high-density IO), UM-IC14 (compact 8-channel IO), UM-HOZ/FLK/DELTAV (protocol/interface adaptation), UM-DB37M/D37SUB/D15 (D-sub interface transfer) and UM-8OPT (relay output) modules, with diversified configurations of analog input/output (AI/AIO), digital input/output (DI/DO), relay switching and multi-system compatibility (S7/C300/DeltaV). All variants feature industrial-grade robustness with wide temperature tolerance (-40°C to +85°C), EMC anti-interference, vibration resistance and flame-retardant housing; support DIN rail mounting, plug-and-play deployment and precise signal transmission, perfectly matching Siemens S7, Emerson DeltaV, Honeywell C300 and other mainstream industrial control systems. The UM series provides a one-stop interface solution for harsh industrial environments, realizing seamless conversion and transmission of analog/digital signals, and efficient docking between field devices and upper control systems.
Core Advantages
- Full-Coverage IO & Interface Function: Integrates AI/AIO analog acquisition, DI/DO digital switching, relay output, protocol adaptation and interface transfer, covering signal conversion, IO expansion and system docking needs of industrial control systems.
- Multi-System Compatibility: Compliant with Siemens S7, Emerson DeltaV, Honeywell C300 and PLC control protocols; supports CS/MT coding matching and multi-brand industrial controller docking, with strong versatility.
- Graded Channel Configuration: Divided into compact 8-channel (IC14) and high-density 32-channel (IC50) core specifications, matching small-scale compact control and large-scale high-density automation system requirements respectively.
- Industrial-Grade Signal Reliability: Supports DRY dry contact/WET wet contact signal transmission, with anti-interference shielding and signal isolation design; stable signal acquisition and output in high-noise industrial environments.
- Flexible Installation & Configuration: Standard DIN rail (NS35) mounting, tool-free wiring and quick connection; modular design for free combination and system expansion; clear status indication for easy on-site debugging and maintenance.
II. Product Classification & Detailed Parameter Table
Strictly aligned with your part number list, the series is categorized by core functional type & module specification for clear differentiation, with a complete parameter table including Part No., Complete Model, Core Parameters, Key Features and Application Scenarios for 1:1 model matching and direct procurement reference (all models adopt industrial-grade design and support standard industrial wiring by default).
| Part No. | Complete Model | Core Parameters | Key Features | Application Scenarios | |
|---|---|---|---|---|---|
| 1. UM-IC50 Series (High-Density IO Modules, Core Mainstream) | 2902752 | UM-IC50/S7 | Type:IC50 base module; Compatibility:Siemens S7 system; DIN rail mount; Industrial-grade | IC50 series standard base module, S7 system dedicated | S7 control system IO module expansion base, high-density automation system docking |
| 2902882 | UM-IC50/8AIO/S7 | Channels:8-channel AIO (analog input/output); System:S7; IC50 spec; Signal isolation | 8-channel analog mixed IO module, S7 compatible | Analog signal acquisition & output for S7 control systems, industrial sensor/actuator signal conversion | |
| 2905900 | UM-IC50/8AI/DRY/F/S7 | Channels:8-channel AI (analog input); Signal type:DRY dry contact; F-grade; S7 compatible | 8-channel dry contact analog input module, high stability | Dry contact analog signal acquisition for S7 systems, harsh field sensor signal collection | |
| 2901936 | UM-IC50/8/AIO/Z/CS1068 | Channels:8-channel AIO; Coding:CS1068; Z-grade; Signal isolation | 8-channel analog IO module with precise coding, custom matching | CS1068 coded analog signal conversion, dedicated for customized S7 automation systems | |
| 2901934 | UM-IC50/32R/NO/DO/CS1060 | Channels:32-channel DO (digital output); Contact:NO (normally open); Coding:CS1060; 32R relay | 32-channel NO dry contact digital output module, precise coding | High-density NO digital signal output for CS1060 coded control systems, actuator control | |
| 2901935 | UM-IC50/32R/NO/DI24DC/CS1061 | Channels:32-channel DI; Voltage:24VDC; Contact:NO; Coding:CS1061; 32R relay | 32-channel 24VDC NO digital input module, coded matching | 24VDC digital signal acquisition for CS1061 coded systems, field sensor signal collection | |
| 2903649 | UM-IC50/32R/DO/1NO/WET/S7 | Channels:32-channel DO; Contact:1NO; Signal type:WET wet contact; S7 compatible | 32-channel wet contact NO digital output module, S7 dedicated | Wet contact digital signal output for S7 systems, high-humidity field actuator control | |
| 2903648 | UM-IC50/32R/DO/1NO/DRY/S7 | Channels:32-channel DO; Contact:1NO; Signal type:DRY dry contact; S7 compatible | 32-channel dry contact NO digital output module, high reliability | Dry contact digital signal output for S7 systems, general industrial actuator control | |
| 2906556 | UM-IC50/32R/CO/DO/F/CS1458 | Channels:32-channel DO; Contact:CO (changeover); F-grade; Coding:CS1458 | 32-channel CO contact digital output module, precise coding | CS1458 coded changeover contact output, customized automation system control | |
| 2905252 | UM-IC50/32R/CO/DO/F/CS1373 | Channels:32-channel DO; Contact:CO; F-grade; Coding:CS1373 | 32-channel CO contact digital output module, dedicated coding | CS1373 coded changeover contact output, high-density industrial control | |
| 2902754 | UM-IC50/32DO/LA/S7 | Channels:32-channel DO; LA-grade; S7 compatible; High load capacity | 32-channel high-load digital output module, S7 dedicated | High-load actuator control for S7 systems, heavy-duty industrial equipment IO expansion | |
| 2903647 | UM-IC50/32DI/LA/S7 | Channels:32-channel DI; LA-grade; S7 compatible; High anti-interference | 32-channel high-anti-interference digital input module, S7 dedicated | High-noise environment signal acquisition for S7 systems, field sensor signal collection | |
| 2902753 | UM-IC50/32DI/F/LA/S7 | Channels:32-channel DI; F+LA dual grade; S7 compatible; Dry contact | 32-channel high-grade digital input module, S7 dedicated | High-reliability dry contact signal acquisition for S7 systems, critical industrial control | |
| 2. UM-IC14 Series (Compact 8-Channel IO Modules) | 2902893 | UM-IC14/8R/DO/2CO/DRY/S7 | Channels:8-channel DO; Contact:2CO; Signal type:DRY; 8R relay; S7 compatible | 8-channel changeover contact dry output module, compact | Small-scale changeover contact output for S7 systems, compact cabinet actuator control |
| 2902889 | UM-IC14/8R/DO/1NO/DRY/S7 | Channels:8-channel DO; Contact:1NO; Signal type:DRY; S7 compatible | 8-channel NO dry contact digital output module, ultra-compact | Compact dry contact output for S7 systems, micro automation equipment IO control | |
| 2902891 | UM-IC14/8R/DO/1CO/DRY/S7 | Channels:8-channel DO; Contact:1CO; Signal type:DRY; S7 compatible | 8-channel changeover contact dry output module, space-saving | Small-scale changeover contact control for S7 systems, narrow cabinet wiring | |
| 2902886 | UM-IC14/8R/DI/1NO/DRY/S7 | Channels:8-channel DI; Contact:1NO; Signal type:DRY; S7 compatible | 8-channel NO dry contact digital input module, compact | Compact dry contact signal acquisition for S7 systems, small field sensor signal collection | |
| 2902888 | UM-IC14/8DI/F/LA/S7 | Channels:8-channel DI; F+LA grade; S7 compatible; High anti-interference | 8-channel high-grade digital input module, ultra-compact | High-reliability signal acquisition for S7 systems, mini industrial control cabinet wiring | |
| 3. UM-HOZ/FLK/DELTAV Series (Protocol Adaptation & Interface Transfer Modules) | 2955276 | UM-HOZ 462/1-1-1-1-2-2/W120 | Type:HOZ multi-channel adapter; Spec:462; W120 grade; Multi-signal adaptation | Multi-channel mixed signal adapter, high flexibility | Multi-type signal conversion and adaptation for industrial control systems, protocol docking |
| 2902085 | UM-FLK14/PTS/MSTB/GF-DI | Interface:FLK14/PTS/MSTB; Type:DI dedicated; GF-grade; Signal isolation | FLK14 interface digital input adapter, MSTB compatible | FLK14-MSTB interface signal conversion, cabinet-internal DI signal transfer | |
| 5603258 | UM-DELTAV/A/SI/BFI/TP | System compatibility:Emerson DeltaV; A/SI grade; BFI/TP coding; Protocol adaptation | DeltaV system dedicated interface module, protocol matching | Emerson DeltaV system signal adaptation and IO expansion, DCS control system docking | |
| 4. UM-DB37M/D37SUB/D15 Series (D-Sub Interface Transfer Modules) | 2901570 | UM-DB37M/16R/DO/NO/J/C300 | Interface:DB37 male; Channels:16-channel DO; Contact:NO; J-grade; Compatibility:Honeywell C300 | DB37M 16-channel NO output module, C300 compatible | Honeywell C300 system DB37 interface digital output, industrial controller signal transfer |
| 2901575 | UM-DB37M/16R/DI/NO/DRY24/C300 | Interface:DB37 male; Channels:16-channel DI; Voltage:24VDC; Signal:DRY; C300 compatible | DB37M 24VDC dry input module, C300 dedicated | Honeywell C300 system DB37 interface signal acquisition, 24VDC sensor signal transfer | |
| 2906944 | UM-D37SUB/M/HC3/DI24V/MR/SI/MT | Interface:D37SUB male; Channels:DI; Voltage:24VDC; HC3/MR grade; SI/MT coding | D37SUB 24VDC digital input module, coded matching | D37SUB interface 24VDC signal acquisition, customized industrial control system docking | |
| 5775148 | UM-D15/S4SI/CS0804 | Interface:D15; Grade:S4SI; Coding:CS0804; Compact | D15 compact interface module, precise coding | D15 interface signal conversion for CS0804 coded systems, small-scale equipment docking | |
| 5. UM-8OPT Series (Relay Output Modules) | 2310594 | UM-8OPT/RT-G24/24DC5A/PLC | Channels:8-channel relay output; Voltage:24VDC; Current:5A; PLC compatible; RT-G24 grade | 8-channel high-current relay output module, PLC dedicated | PLC system 8-channel relay output, high-load industrial actuator control |
III. Nomenclature Decoding: UM Series Model Structure & Full Definition
Universal Model Format
UM-[Module Series/Spec]-[Channel/IO Type]-[Signal/Contact Type]-[System/Coding/Grade]-[Suffix]
Key Component & Suffix Interpretation (Critical for Selection)
- UM: Phoenix industrial interface & IO module series identifier
- Core Module Series (Primary Differentiator):
- IC50 = High-density IO module (32-channel mainstream, large-spec control)
- IC14 = Compact IO module (8-channel, small-space/mini control)
- HOZ = Multi-channel signal adapter module (multi-type signal conversion)
- FLK14/DELTAV = Protocol/interface adaptation module (FLK14 interface/DeltaV system dedicated)
- DB37M/D37SUB/D15 = D-sub interface transfer module (DB37/D15 mechanical interface)
- 8OPT = 8-channel relay output module (high-load switching)
- IO & Signal Type Code (Core Function):
- AI = Analog Input (analog signal collection)
- AIO = Analog Input/Output (mixed analog signal conversion)
- DI = Digital Input (digital signal collection)
- DO = Digital Output (digital signal output)
- 8/32 = Channel count (8-channel compact /32-channel high-density)
- R = Relay core (relay switching type IO module)
- Contact & Signal Characteristic:
- NO = Normally Open contact (default for general control)
- CO = Changeover contact (1NO+1NC, dual-state output)
- DRY = Dry contact signal (no external power supply required)
- WET = Wet contact signal (with external power supply, high-humidity adaptation)
- 24DC/24VDC = Working voltage (24V DC, industrial standard)
- System Compatibility & Coding:
- S7 = Siemens S7 PLC/DCS system compatible
- C300 = Honeywell C300 system compatible
- DELTAV = Emerson DeltaV system compatible
- PLC = General PLC system universal
- CSxxxx = Phoenix precise coding (custom system matching)
- MT/SI = Coding grade (interface/protocol matching)
- Grade & Functional Suffixes:
- LA = High-load/anti-interference grade (enhanced performance)
- F = High-stability grade (critical control application)
- GF/HC3/MR = Material/protection grade (industrial environmental adaptation)
- TP/BFI = Protocol adaptation code (DeltaV system dedicated)
IV. 3-Step Quick Selection Technique (100% Accurate Matching)
Follow the control system matching → IO function & channel selection → signal/contact confirmation logic to quickly lock the correct model, avoid complex parameter comparison and fully adapt to industrial automation control system IO expansion and interface adaptation requirements.
Step 1: Match the Corresponding Module by Upper Control System
- Siemens S7 system → All models marked with S7 suffix (2902752/2902882/2902893)
- Honeywell C300 system → UM-DB37M series with C300 suffix (2901570/2901575)
- Emerson DeltaV system → UM-DELTAV dedicated module (5603258)
- General PLC system → PLC suffix module (2310594) or non-specified universal models
- Custom coded system → Models with CSxxxx coding (2901934/2906556)
Step 2: Select IO Type & Channel Count by Business Demand
- Analog signal acquisition/output → AI/AIO marked modules (2902882/2905900)
- Digital signal input → DI marked modules (2903647/2902886)
- Digital signal output → DO marked modules (2903648/2902754)
- Relay switching output → Modules with R/8OPT suffix (2310594/2902893)
- Channel count selection: 8-channel compact control → IC14 series (2902888); 32-channel high-density control → IC50 series (2902754); 16-channel D-sub interface → DB37M series (2901570)
Step 3: Confirm Signal Type & Contact Characteristic (Final Selection)
- Dry contact signal transmission (no external power) → Select DRY suffix modules (2905900/2902889)
- Wet contact signal transmission (with external power/humid environment) → Select WET suffix modules (2903649)
- General control output → NO (normally open) contact modules (2903648/2902889)
- Dual-state switching control → CO (changeover) contact modules (2906556/2902893)
- High-load/anti-interference requirement → LA/F grade modules (2902753/2903647)
- D-sub mechanical interface transfer → DB37M/D37SUB/D15 series (2901570/5775148)
V. Selection Pitfall Avoidance Guide (Critical for Control System Stability)
Avoid the 6 most common selection errors of the UM series to ensure stable signal transmission, system compatibility and electrical safety in harsh industrial environments, eliminating IO module misconnection, signal loss and control failure risks.
- System Compatibility Mismatch: S7 system using DeltaV/C300 dedicated modules → Strictly verify the upper control system model and select the corresponding suffix modules (S7/C300/DELTAV) to ensure protocol docking.
- Signal Type Error: Wet contact field using DRY dry contact modules → Distinguish DRY/WET signal characteristics and select matching variants; avoid signal acquisition failure caused by type mismatch.
- Channel Count Underconfiguration: 30-channel IO control using 8-channel IC14 modules → Select 32-channel IC50 series (2902754) or cascade multiple modules to meet high-density control needs.
- Contact Type Misuse: Changeover contact control using NO single-contact modules → Select CO suffix modules (2906556/2902893) for dual-state switching requirements.
- Grade Neglect: High-noise/high-load environments using standard grade modules → Add LA/F grade variants (2902753/2903647) for enhanced anti-interference and load capacity.
- Coding Misunderstanding: Custom system matching using non-CS coded modules → Verify CSxxxx coding and select the corresponding models (2901934/2905252) to ensure precise system docking.
VI. Conclusion: Core Interface Components for Industrial Control System Integration
The Phoenix UM series delivers a comprehensive industrial IO interface and signal conversion solution covering high-density/compact IO modules, protocol adaptation modules and interface transfer modules, with diversified channel configurations, signal types and system compatibility. These modules are the core connection components between industrial field devices and upper control systems (S7/C300/DeltaV/PLC), realizing stable acquisition, conversion and output of analog/digital signals, and efficient expansion of industrial control system IO capacity. With industrial-grade reliability, multi-system compatibility and flexible configuration, the UM series perfectly matches small-scale compact automation control, large-scale high-density DCS/PLC systems and customized industrial control scenarios, forming a complete signal transmission chain from field sensors/actuators to upper controllers.