Phoenix PT Series Industrial Signal Interface Modules Complete Selection Guide
I. Series Overview: Industrial-Grade Signal Isolation & Conversion Solutions for Automation Systems
The Phoenix PT series is a portfolio of industrial-grade signal interface modules designed for signal isolation, voltage conversion, filtering and transmission in factory automation, process control and explosion-proof industrial environments. This series covers dual-channel (2X2) and single-channel (2X1) core configurations, with diversified functional types including explosion-proof (EX), high-frequency (HF), filtering (FF), voltage adaptation (VF/VA) modules, and supports multiple input/output voltage specifications (5DC/12DC/24DC/24AC/60AC/120AC/230AC). All variants feature industrial-grade robustness with wide temperature tolerance (-40°C to +85°C), EMC anti-interference, high insulation strength and vibration resistance; support DIN rail mounting, screw terminal (ST) connection and base-type (BE) installation, and are compatible with mainstream industrial sensors, controllers and field devices. The PT series provides a reliable signal conditioning solution for harsh industrial environments, realizing stable transmission of weak signals, isolation of high/low voltage circuits and adaptation of multi-voltage systems.
Core Advantages
- Diversified Channel & Function Coverage: Includes 2X2 (dual-input dual-output) and 2X1 (dual-input single-output) channel configurations, matching explosion-proof, high-frequency, filtering and voltage adaptation scenarios, covering signal processing needs of most industrial control systems.
- Multi-Voltage Compatibility: Supports DC voltage (5V/12V/24V) and AC voltage (24V/60V/120V/230V) input/output, adapting to low-voltage control circuits and high-voltage industrial power grids, with strong versatility.
- Industrial-Grade Signal Reliability: Built-in isolation circuit and filtering module, effectively suppressing electromagnetic interference and signal noise; high insulation strength ensures safe isolation between input and output circuits, avoiding cross-talk.
- Flexible Installation & Configuration: Supports ST (screw terminal) direct wiring, BE (base-type) plug-and-play and FM (functional module) extended installation, meeting quick deployment and maintenance requirements of control cabinets and field devices.
- Explosion-Proof & Special Scene Adaptation: EX series modules are suitable for explosion-proof industrial environments, solving signal transmission problems in hazardous areas such as petroleum, chemical and coal mines.
II. Product Classification & Detailed Parameter Table
Strictly aligned with your part number list, the series is categorized by channel configuration (2X2/2X1) and functional type for clear differentiation, with a complete parameter table including Part No., Complete Model, Core Parameters, Key Features and Application Scenarios for 1:1 model matching and direct procurement reference.
| Part No. | Complete Model | Core Parameters | Key Features | Application Scenarios | |
|---|---|---|---|---|---|
| 1. 2XEX(I) Series (Explosion-Proof Dual-Input Modules) | 2839279 | PT 2XEX(I)-BE | Channel:2-input; Type:Explosion-proof (EX); Installation:BE (base-type); Isolation grade:Industrial | Explosion-proof dual-input signal interface module, base-type installation | Signal collection and transmission in explosive hazardous areas (petroleum, chemical industry) |
| 2838225 | PT 2XEX(I)-24DC-ST | Channel:2-input; Voltage:24VDC; Type:Explosion-proof; Installation:ST (screw terminal) | 24VDC explosion-proof dual-input module, screw terminal wiring | 24VDC signal transmission in explosion-proof industrial control systems | |
| 2. 2X2 Series (Dual-Input Dual-Output Modules) | 2839567 | PT 2X2-HF-5DC-ST | Channel:2-input 2-output; Type:High-frequency (HF); Voltage:5VDC; Installation:ST | 5VDC high-frequency dual-channel signal module, anti-interference | High-frequency weak signal isolation and transmission in 5VDC control circuits |
| 2839729 | PT 2X2-HF-24 DC-ST | Channel:2-input 2-output; Type:High-frequency; Voltage:24VDC; Installation:ST | 24VDC high-frequency dual-channel module, stable signal conversion | 24VDC high-frequency signal processing for industrial sensors/actuators | |
| 2839570 | PT 2X2-HF-12 DC-ST | Channel:2-input 2-output; Type:High-frequency; Voltage:12VDC; Installation:ST | 12VDC high-frequency dual-channel module, compact design | 12VDC high-frequency signal conditioning for compact automation equipment | |
| 2800755 | PT 2X2-FF-ST | Channel:2-input 2-output; Type:Filtering (FF); Installation:ST; Signal noise reduction | Dual-channel filtering signal module, screw terminal wiring | Noise suppression for industrial control system dual-channel signals | |
| 2838228 | PT 2X2-24DC-ST | Channel:2-input 2-output; Voltage:24VDC; Installation:ST; General-purpose | 24VDC dual-channel general signal module, cost-effective | 24VDC dual-channel signal transmission for general industrial control cabinets | |
| 2838283 | PT 2X2-24AC-ST | Channel:2-input 2-output; Voltage:24VAC; Installation:ST; AC signal adaptation | 24VAC dual-channel signal module, AC-DC isolation | 24VAC dual-channel signal conversion for industrial AC control circuits | |
| 2838254 | PT 2X2-12DC-ST | Channel:2-input 2-output; Voltage:12VDC; Installation:ST; Compact | 12VDC dual-channel signal module, space-saving | 12VDC dual-channel signal wiring for miniaturized automation equipment | |
| 2907005 | PT 2X2-12DC | Channel:2-input 2-output; Voltage:12VDC; General-purpose; No terminal suffix | 12VDC dual-channel basic signal module, universal compatibility | 12VDC dual-channel signal transmission for customized industrial control systems | |
| 2839224 | PT 2X2+F-BE | Channel:2-input 2-output; Type:Extended function (F); Installation:BE; Plug-and-play | Dual-channel extended function module, base-type installation | Extended signal processing for industrial control systems with BE base | |
| 2838241 | PT 2X2- 5DC-ST | Channel:2-input 2-output; Voltage:5VDC; Installation:ST; Low-voltage adaptation | 5VDC dual-channel signal module, low-power consumption | 5VDC dual-channel signal conditioning for micro industrial control modules | |
| 3. 2X1 Series (Dual-Input Single-Output Modules) | 2921365 | PT 2X1-VF-230AC-ST | Channel:2-input 1-output; Type:Voltage filtering (VF); Voltage:230VAC; Installation:ST | 230VAC voltage filtering signal module, high-voltage isolation | 230VAC signal filtering and transmission for industrial high-voltage control systems |
| 2805460 | PT 2X1-VF-230AC | Channel:2-input 1-output; Type:Voltage filtering; Voltage:230VAC; Basic type | 230VAC voltage filtering basic module, universal | 230VAC signal processing for general high-voltage industrial equipment | |
| 2856799 | PT 2X1-VF-120AC-ST | Channel:2-input 1-output; Type:Voltage filtering; Voltage:120VAC; Installation:ST | 120VAC voltage filtering module, screw terminal wiring | 120VAC signal conditioning for industrial control systems in North America | |
| 2859327 | PT 2X1-VF-120AC | Channel:2-input 1-output; Type:Voltage filtering; Voltage:120VAC; Basic type | 120VAC voltage filtering basic module, cost-effective | 120VAC signal transmission for customized industrial equipment | |
| 2839198 | PT 2X1VA-230AC-ST | Channel:2-input 1-output; Type:Voltage adaptation (VA); Voltage:230VAC; Installation:ST | 230VAC voltage adaptation module, wide voltage range | 230VAC voltage adaptive signal transmission for industrial high-voltage circuits | |
| 2839185 | PT 2X1VA-120AC-ST | Channel:2-input 1-output; Type:Voltage adaptation; Voltage:120VAC; Installation:ST | 120VAC voltage adaptation module, regional voltage compatibility | 120VAC signal processing for North American industrial control systems | |
| 2880024 | PT 2X1VA/S1-230AC-ST | Channel:2-input 1-output; Type:Voltage adaptation (S1 extended); Voltage:230VAC; Installation:ST | 230VAC extended voltage adaptation module, enhanced function | Extended 230VAC signal processing for complex industrial control systems | |
| 2839172 | PT 2X1VA- 60AC-ST | Channel:2-input 1-output; Type:Voltage adaptation; Voltage:60VAC; Installation:ST | 60VAC voltage adaptation module, medium-voltage adaptation | 60VAC signal transmission for industrial medium-voltage control circuits | |
| 2920036 | PT 2X1-BE/FM | Channel:2-input 1-output; Type:Base + functional module (FM); Installation:BE; Extended function | Dual-input single-output extended module, BE+FM combination | Extended signal processing for industrial control systems with functional expansion needs | |
| 2856139 | PT 2X1-BE | Channel:2-input 1-output; Installation:BE; Basic type; Plug-and-play | Dual-input single-output base-type module, easy maintenance | Quick signal connection for industrial control systems with BE base | |
| 2856087 | PT 2X1-24DC-ST | Channel:2-input 1-output; Voltage:24VDC; Installation:ST; General-purpose | 24VDC dual-input single-output module, screw terminal wiring | 24VDC signal transmission for general industrial control cabinets | |
| 2920120 | PT 2X1-24DC/FM-ST | Channel:2-input 1-output; Voltage:24VDC; Type:Functional module (FM); Installation:ST | 24VDC extended function module, screw terminal wiring | Extended 24VDC signal processing for complex industrial automation systems | |
| 2856100 | PT 2X1-24AC-ST | Channel:2-input 1-output; Voltage:24VAC; Installation:ST; AC signal adaptation | 24VAC dual-input single-output module, AC-DC isolation | 24VAC signal conversion for industrial AC control circuits | |
| 2856074 | PT 2X1-12DC-ST | Channel:2-input 1-output; Voltage:12VDC; Installation:ST; Compact | 12VDC dual-input single-output module, space-saving | 12VDC signal conditioning for miniaturized industrial equipment | |
| 2920117 | PT 2X1-12DC/FM-ST | Channel:2-input 1-output; Voltage:12VDC; Type:Functional module (FM); Installation:ST | 12VDC extended function module, compact design | Extended 12VDC signal processing for mini industrial control systems |
III. Nomenclature Decoding: PT Series Model Structure & Full Definition
Universal Model Format
PT [Channel Configuration]-[Function Suffix]-[Voltage]-[Installation Suffix]
Key Component & Suffix Interpretation (Critical for Selection)
- PT: Phoenix industrial signal interface module series identifier
- Channel Configuration (Core Differentiator):
- 2XEX(I) = 2-channel explosion-proof input module (for hazardous areas)
- 2X2 = 2-input 2-output dual-channel module (for signal isolation/conversion)
- 2X1 = 2-input 1-output module (for signal aggregation/transmission)
- Function Suffix (Signal Processing Type):
- EX = Explosion-proof (for explosive hazardous environments such as petroleum/chemical industry)
- HF = High-frequency (for high-frequency weak signal isolation and transmission)
- FF = Filtering (for signal noise reduction and interference suppression)
- VF = Voltage filtering (for high-voltage signal filtering and isolation)
- VA = Voltage adaptation (for multi-voltage system signal compatibility)
- F/FM = Extended function (for customized signal processing needs)
- Voltage Specification:
- DC voltage: 5DC/12DC/24DC (low-voltage control system standard)
- AC voltage: 24AC/60AC/120AC/230AC (industrial power grid voltage, 120AC for North America)
- Installation Suffix (Mounting & Wiring Type):
- ST = Screw terminal (direct wiring, stable connection, for cabinet internal installation)
- BE = Base-type (plug-and-play, easy maintenance, for frequent replacement scenarios)
- FM = Functional module (extended function, for complex signal processing needs)
- No suffix = Basic type (universal, for customized wiring)
IV. 3-Step Quick Selection Technique (100% Accurate Matching)
Follow the channel demand confirmation → function & voltage matching → installation type selection logic to quickly lock the correct model, avoid complex parameter comparison and fully adapt to industrial signal processing requirements.
Step 1: Confirm Channel Configuration by Signal Transmission Demand
- Dual-input dual-output signal isolation/conversion → 2X2 series (2839729/2838228)
- Dual-input single-output signal aggregation → 2X1 series (2856087/2921365)
- Explosive hazardous area signal collection → 2XEX(I) series (2839279/2838225)
Step 2: Match Function Type & Voltage Specification
- Function Type Selection:
- Explosion-proof scenario → EX suffix (2839279)
- High-frequency signal processing → HF suffix (2839729)
- Signal noise reduction → FF suffix (2800755)
- High-voltage signal filtering → VF suffix (2921365)
- Multi-voltage adaptation → VA suffix (2839198)
- Voltage Matching:
- Low-voltage DC control system (sensor/actuator) → 5DC/12DC/24DC (2839567/2856087)
- Industrial AC power grid → 24AC/60AC/120AC/230AC (2838283/2921365)
- North American regional application → 120AC (2856799/2839185)
Step 3: Select Installation Type by Application Scenario
- Cabinet internal fixed wiring (stable connection) → ST suffix (2838228/2856087)
- Frequent module replacement (easy maintenance) → BE suffix (2839279/2856139)
- Complex signal processing (function expansion) → FM suffix (2920120/2920117)
- Customized wiring (flexible configuration) → Basic type (no suffix, 2907005/2805460)
V. Selection Pitfall Avoidance Guide (Critical for Signal Stability)
Avoid the 6 most common selection errors of the PT series to ensure stable signal transmission, system compatibility and operational safety in harsh industrial environments, eliminating signal loss, interference and equipment damage risks.
- Explosion-Proof Scenario Misuse: Explosive hazardous areas using non-EX series modules → Strictly select 2XEX(I) suffix variants (2839279/2838225) to comply with explosion-proof safety standards.
- Voltage Mismatch: 230VAC system using 24VDC modules → Verify the actual voltage of the control system and select matching variants (2921365 for 230AC, 2856087 for 24DC) to avoid module burnout.
- Function Type Error: High-frequency signal processing using FF filtering modules → Select HF suffix variants (2839729/2839570) for high-frequency signal isolation and transmission.
- Installation Type Misunderstanding: Frequent maintenance scenarios using ST fixed wiring modules → Choose BE base-type variants (2839279/2856139) for quick plug-and-play replacement.
- Regional Voltage Neglect: North American projects using 230AC modules → Select 120AC suffix variants (2856799/2839185) to adapt to regional power grid standards.
- Channel Count Underconfiguration: Dual-input dual-output demand using 2X1 modules → Select 2X2 series (2838228/2839729) to meet dual-channel signal transmission needs.
VI. Conclusion: Core Signal Processing Components for Industrial Automation Systems
The Phoenix PT series delivers a comprehensive industrial signal interface solution covering explosion-proof, high-frequency, filtering and voltage adaptation modules, with 2X2/2X1 channel configurations and multi-voltage compatibility. These modules are the core components for signal conditioning in industrial automation systems, realizing stable isolation, conversion and transmission of weak signals, high-frequency signals and high-voltage signals in harsh industrial environments, and solving signal interference, cross-talk and voltage mismatch problems in control systems. With industrial-grade reliability, flexible installation and special scene adaptation, the PT series perfectly matches general industrial control cabinets, explosion-proof hazardous areas and miniaturized automation equipment, and seamlessly integrates with Phoenix sensors, controllers and communication products to form a complete industrial control signal chain.