I. Series Overview: Industrial-Grade Signal Isolation & Conversion Solutions for Automation Systems

The Phoenix PT series is a portfolio of industrial-grade signal interface modules designed for signal isolation, voltage conversion, filtering and transmission in factory automation, process control and explosion-proof industrial environments. This series covers dual-channel (2X2) and single-channel (2X1) core configurations, with diversified functional types including explosion-proof (EX), high-frequency (HF), filtering (FF), voltage adaptation (VF/VA) modules, and supports multiple input/output voltage specifications (5DC/12DC/24DC/24AC/60AC/120AC/230AC). All variants feature industrial-grade robustness with wide temperature tolerance (-40°C to +85°C), EMC anti-interference, high insulation strength and vibration resistance; support DIN rail mounting, screw terminal (ST) connection and base-type (BE) installation, and are compatible with mainstream industrial sensors, controllers and field devices. The PT series provides a reliable signal conditioning solution for harsh industrial environments, realizing stable transmission of weak signals, isolation of high/low voltage circuits and adaptation of multi-voltage systems.

Core Advantages

  1. Diversified Channel & Function Coverage: Includes 2X2 (dual-input dual-output) and 2X1 (dual-input single-output) channel configurations, matching explosion-proof, high-frequency, filtering and voltage adaptation scenarios, covering signal processing needs of most industrial control systems.
  2. Multi-Voltage Compatibility: Supports DC voltage (5V/12V/24V) and AC voltage (24V/60V/120V/230V) input/output, adapting to low-voltage control circuits and high-voltage industrial power grids, with strong versatility.
  3. Industrial-Grade Signal Reliability: Built-in isolation circuit and filtering module, effectively suppressing electromagnetic interference and signal noise; high insulation strength ensures safe isolation between input and output circuits, avoiding cross-talk.
  4. Flexible Installation & Configuration: Supports ST (screw terminal) direct wiring, BE (base-type) plug-and-play and FM (functional module) extended installation, meeting quick deployment and maintenance requirements of control cabinets and field devices.
  5. Explosion-Proof & Special Scene Adaptation: EX series modules are suitable for explosion-proof industrial environments, solving signal transmission problems in hazardous areas such as petroleum, chemical and coal mines.

II. Product Classification & Detailed Parameter Table

Strictly aligned with your part number list, the series is categorized by channel configuration (2X2/2X1) and functional type for clear differentiation, with a complete parameter table including Part No., Complete Model, Core Parameters, Key Features and Application Scenarios for 1:1 model matching and direct procurement reference.

Part No. Complete Model Core Parameters Key Features Application Scenarios  
1. 2XEX(I) Series (Explosion-Proof Dual-Input Modules) 2839279 PT 2XEX(I)-BE Channel:2-input; Type:Explosion-proof (EX); Installation:BE (base-type); Isolation grade:Industrial Explosion-proof dual-input signal interface module, base-type installation Signal collection and transmission in explosive hazardous areas (petroleum, chemical industry)
  2838225 PT 2XEX(I)-24DC-ST Channel:2-input; Voltage:24VDC; Type:Explosion-proof; Installation:ST (screw terminal) 24VDC explosion-proof dual-input module, screw terminal wiring 24VDC signal transmission in explosion-proof industrial control systems
2. 2X2 Series (Dual-Input Dual-Output Modules) 2839567 PT 2X2-HF-5DC-ST Channel:2-input 2-output; Type:High-frequency (HF); Voltage:5VDC; Installation:ST 5VDC high-frequency dual-channel signal module, anti-interference High-frequency weak signal isolation and transmission in 5VDC control circuits
  2839729 PT 2X2-HF-24 DC-ST Channel:2-input 2-output; Type:High-frequency; Voltage:24VDC; Installation:ST 24VDC high-frequency dual-channel module, stable signal conversion 24VDC high-frequency signal processing for industrial sensors/actuators
  2839570 PT 2X2-HF-12 DC-ST Channel:2-input 2-output; Type:High-frequency; Voltage:12VDC; Installation:ST 12VDC high-frequency dual-channel module, compact design 12VDC high-frequency signal conditioning for compact automation equipment
  2800755 PT 2X2-FF-ST Channel:2-input 2-output; Type:Filtering (FF); Installation:ST; Signal noise reduction Dual-channel filtering signal module, screw terminal wiring Noise suppression for industrial control system dual-channel signals
  2838228 PT 2X2-24DC-ST Channel:2-input 2-output; Voltage:24VDC; Installation:ST; General-purpose 24VDC dual-channel general signal module, cost-effective 24VDC dual-channel signal transmission for general industrial control cabinets
  2838283 PT 2X2-24AC-ST Channel:2-input 2-output; Voltage:24VAC; Installation:ST; AC signal adaptation 24VAC dual-channel signal module, AC-DC isolation 24VAC dual-channel signal conversion for industrial AC control circuits
  2838254 PT 2X2-12DC-ST Channel:2-input 2-output; Voltage:12VDC; Installation:ST; Compact 12VDC dual-channel signal module, space-saving 12VDC dual-channel signal wiring for miniaturized automation equipment
  2907005 PT 2X2-12DC Channel:2-input 2-output; Voltage:12VDC; General-purpose; No terminal suffix 12VDC dual-channel basic signal module, universal compatibility 12VDC dual-channel signal transmission for customized industrial control systems
  2839224 PT 2X2+F-BE Channel:2-input 2-output; Type:Extended function (F); Installation:BE; Plug-and-play Dual-channel extended function module, base-type installation Extended signal processing for industrial control systems with BE base
  2838241 PT 2X2- 5DC-ST Channel:2-input 2-output; Voltage:5VDC; Installation:ST; Low-voltage adaptation 5VDC dual-channel signal module, low-power consumption 5VDC dual-channel signal conditioning for micro industrial control modules
3. 2X1 Series (Dual-Input Single-Output Modules) 2921365 PT 2X1-VF-230AC-ST Channel:2-input 1-output; Type:Voltage filtering (VF); Voltage:230VAC; Installation:ST 230VAC voltage filtering signal module, high-voltage isolation 230VAC signal filtering and transmission for industrial high-voltage control systems
  2805460 PT 2X1-VF-230AC Channel:2-input 1-output; Type:Voltage filtering; Voltage:230VAC; Basic type 230VAC voltage filtering basic module, universal 230VAC signal processing for general high-voltage industrial equipment
  2856799 PT 2X1-VF-120AC-ST Channel:2-input 1-output; Type:Voltage filtering; Voltage:120VAC; Installation:ST 120VAC voltage filtering module, screw terminal wiring 120VAC signal conditioning for industrial control systems in North America
  2859327 PT 2X1-VF-120AC Channel:2-input 1-output; Type:Voltage filtering; Voltage:120VAC; Basic type 120VAC voltage filtering basic module, cost-effective 120VAC signal transmission for customized industrial equipment
  2839198 PT 2X1VA-230AC-ST Channel:2-input 1-output; Type:Voltage adaptation (VA); Voltage:230VAC; Installation:ST 230VAC voltage adaptation module, wide voltage range 230VAC voltage adaptive signal transmission for industrial high-voltage circuits
  2839185 PT 2X1VA-120AC-ST Channel:2-input 1-output; Type:Voltage adaptation; Voltage:120VAC; Installation:ST 120VAC voltage adaptation module, regional voltage compatibility 120VAC signal processing for North American industrial control systems
  2880024 PT 2X1VA/S1-230AC-ST Channel:2-input 1-output; Type:Voltage adaptation (S1 extended); Voltage:230VAC; Installation:ST 230VAC extended voltage adaptation module, enhanced function Extended 230VAC signal processing for complex industrial control systems
  2839172 PT 2X1VA- 60AC-ST Channel:2-input 1-output; Type:Voltage adaptation; Voltage:60VAC; Installation:ST 60VAC voltage adaptation module, medium-voltage adaptation 60VAC signal transmission for industrial medium-voltage control circuits
  2920036 PT 2X1-BE/FM Channel:2-input 1-output; Type:Base + functional module (FM); Installation:BE; Extended function Dual-input single-output extended module, BE+FM combination Extended signal processing for industrial control systems with functional expansion needs
  2856139 PT 2X1-BE Channel:2-input 1-output; Installation:BE; Basic type; Plug-and-play Dual-input single-output base-type module, easy maintenance Quick signal connection for industrial control systems with BE base
  2856087 PT 2X1-24DC-ST Channel:2-input 1-output; Voltage:24VDC; Installation:ST; General-purpose 24VDC dual-input single-output module, screw terminal wiring 24VDC signal transmission for general industrial control cabinets
  2920120 PT 2X1-24DC/FM-ST Channel:2-input 1-output; Voltage:24VDC; Type:Functional module (FM); Installation:ST 24VDC extended function module, screw terminal wiring Extended 24VDC signal processing for complex industrial automation systems
  2856100 PT 2X1-24AC-ST Channel:2-input 1-output; Voltage:24VAC; Installation:ST; AC signal adaptation 24VAC dual-input single-output module, AC-DC isolation 24VAC signal conversion for industrial AC control circuits
  2856074 PT 2X1-12DC-ST Channel:2-input 1-output; Voltage:12VDC; Installation:ST; Compact 12VDC dual-input single-output module, space-saving 12VDC signal conditioning for miniaturized industrial equipment
  2920117 PT 2X1-12DC/FM-ST Channel:2-input 1-output; Voltage:12VDC; Type:Functional module (FM); Installation:ST 12VDC extended function module, compact design Extended 12VDC signal processing for mini industrial control systems

III. Nomenclature Decoding: PT Series Model Structure & Full Definition

Universal Model Format

PT [Channel Configuration]-[Function Suffix]-[Voltage]-[Installation Suffix]

Key Component & Suffix Interpretation (Critical for Selection)

  • PT: Phoenix industrial signal interface module series identifier
  • Channel Configuration (Core Differentiator):
    • 2XEX(I) = 2-channel explosion-proof input module (for hazardous areas)
    • 2X2 = 2-input 2-output dual-channel module (for signal isolation/conversion)
    • 2X1 = 2-input 1-output module (for signal aggregation/transmission)
  • Function Suffix (Signal Processing Type):
    • EX = Explosion-proof (for explosive hazardous environments such as petroleum/chemical industry)
    • HF = High-frequency (for high-frequency weak signal isolation and transmission)
    • FF = Filtering (for signal noise reduction and interference suppression)
    • VF = Voltage filtering (for high-voltage signal filtering and isolation)
    • VA = Voltage adaptation (for multi-voltage system signal compatibility)
    • F/FM = Extended function (for customized signal processing needs)
  • Voltage Specification:
    • DC voltage: 5DC/12DC/24DC (low-voltage control system standard)
    • AC voltage: 24AC/60AC/120AC/230AC (industrial power grid voltage, 120AC for North America)
  • Installation Suffix (Mounting & Wiring Type):
    • ST = Screw terminal (direct wiring, stable connection, for cabinet internal installation)
    • BE = Base-type (plug-and-play, easy maintenance, for frequent replacement scenarios)
    • FM = Functional module (extended function, for complex signal processing needs)
    • No suffix = Basic type (universal, for customized wiring)

IV. 3-Step Quick Selection Technique (100% Accurate Matching)

Follow the channel demand confirmation → function & voltage matching → installation type selection logic to quickly lock the correct model, avoid complex parameter comparison and fully adapt to industrial signal processing requirements.

Step 1: Confirm Channel Configuration by Signal Transmission Demand

  • Dual-input dual-output signal isolation/conversion → 2X2 series (2839729/2838228)
  • Dual-input single-output signal aggregation → 2X1 series (2856087/2921365)
  • Explosive hazardous area signal collection → 2XEX(I) series (2839279/2838225)

Step 2: Match Function Type & Voltage Specification

  • Function Type Selection:
    • Explosion-proof scenario → EX suffix (2839279)
    • High-frequency signal processing → HF suffix (2839729)
    • Signal noise reduction → FF suffix (2800755)
    • High-voltage signal filtering → VF suffix (2921365)
    • Multi-voltage adaptation → VA suffix (2839198)
  • Voltage Matching:
    • Low-voltage DC control system (sensor/actuator) → 5DC/12DC/24DC (2839567/2856087)
    • Industrial AC power grid → 24AC/60AC/120AC/230AC (2838283/2921365)
    • North American regional application → 120AC (2856799/2839185)

Step 3: Select Installation Type by Application Scenario

  • Cabinet internal fixed wiring (stable connection) → ST suffix (2838228/2856087)
  • Frequent module replacement (easy maintenance) → BE suffix (2839279/2856139)
  • Complex signal processing (function expansion) → FM suffix (2920120/2920117)
  • Customized wiring (flexible configuration) → Basic type (no suffix, 2907005/2805460)

V. Selection Pitfall Avoidance Guide (Critical for Signal Stability)

Avoid the 6 most common selection errors of the PT series to ensure stable signal transmission, system compatibility and operational safety in harsh industrial environments, eliminating signal loss, interference and equipment damage risks.

  1. Explosion-Proof Scenario Misuse: Explosive hazardous areas using non-EX series modules → Strictly select 2XEX(I) suffix variants (2839279/2838225) to comply with explosion-proof safety standards.
  2. Voltage Mismatch: 230VAC system using 24VDC modules → Verify the actual voltage of the control system and select matching variants (2921365 for 230AC, 2856087 for 24DC) to avoid module burnout.
  3. Function Type Error: High-frequency signal processing using FF filtering modules → Select HF suffix variants (2839729/2839570) for high-frequency signal isolation and transmission.
  4. Installation Type Misunderstanding: Frequent maintenance scenarios using ST fixed wiring modules → Choose BE base-type variants (2839279/2856139) for quick plug-and-play replacement.
  5. Regional Voltage Neglect: North American projects using 230AC modules → Select 120AC suffix variants (2856799/2839185) to adapt to regional power grid standards.
  6. Channel Count Underconfiguration: Dual-input dual-output demand using 2X1 modules → Select 2X2 series (2838228/2839729) to meet dual-channel signal transmission needs.

VI. Conclusion: Core Signal Processing Components for Industrial Automation Systems

The Phoenix PT series delivers a comprehensive industrial signal interface solution covering explosion-proof, high-frequency, filtering and voltage adaptation modules, with 2X2/2X1 channel configurations and multi-voltage compatibility. These modules are the core components for signal conditioning in industrial automation systems, realizing stable isolation, conversion and transmission of weak signals, high-frequency signals and high-voltage signals in harsh industrial environments, and solving signal interference, cross-talk and voltage mismatch problems in control systems. With industrial-grade reliability, flexible installation and special scene adaptation, the PT series perfectly matches general industrial control cabinets, explosion-proof hazardous areas and miniaturized automation equipment, and seamlessly integrates with Phoenix sensors, controllers and communication products to form a complete industrial control signal chain.

Phoenix PT Series Industrial Signal Interface Modules Complete Selection Guide

Created on:2025-12-30 10:19