Phoenix EM/EMM Series Industrial Relays, Gateways & Switch Modules Complete Selection Guide
I. Series Overview: Industrial-Grade Control, Communication & Switching Solutions
The Phoenix EM/EMM series is a comprehensive portfolio of industrial voltage monitoring relays, protocol gateways and 3-channel switch modules, designed for signal monitoring, protocol conversion and load switching in factory automation, process control and hazardous area systems. The series covers three core categories:
- EMR Voltage Monitoring Relay: Single-channel undervoltage monitoring for 230VAC systems
- EM Gateways: Multi-protocol communication gateways (RS485/Profinet/Profibus/Modbus) compatible with IFS systems
- EMM 3-Channel Switch Modules: AC/DC-controlled AC load switching modules, including explosion-proof (EXM) variantsAll models feature industrial-grade robustness, wide temperature tolerance (-20°C to +70°C), EMC anti-interference performance and DIN rail mounting compatibility, seamlessly integrating with Phoenix IFS series devices and third-party industrial control systems.
Core Advantages
- Multi-Function Coverage: Integrates voltage monitoring, protocol conversion and load switching in one product series, meeting diverse industrial control needs.
- Protocol Compatibility: EM gateways support mainstream industrial protocols (Profinet/Profibus/Modbus/RS485), realizing seamless data interaction between heterogeneous systems.
- Dual Voltage Control: EMM switch modules support 24VDC/230VAC control voltages and 500VAC load switching, adapting to different control circuit configurations.
- Explosion-Proof Option: EMM 3-24DC/500AC-90-EXM-IFS supports hazardous area applications, complying with explosion-proof safety standards.
- System Compatibility: All models are compatible with IFS series devices, ensuring stable integration into Phoenix industrial control ecosystems.
II. Product Classification & Detailed Parameter Table
Strictly aligned with your part number list, the series is categorized by core function (Relay/Gateway/Switch Module) for clear differentiation, with a complete parameter table including Part No., Model, Core Parameters, Key Features and Application Scenarios.
| Part No. | Complete Model | Core Parameters | Key Features | Application Scenarios |
|---|---|---|---|---|
| 1. EM Series Voltage Monitoring Relay | 2764580 | EMR-UAC/1/UV-230V | Type:Undervoltage monitoring relay; Control voltage:230VAC; Channel:1; Function:Undervoltage protection | 230VAC system undervoltage monitoring; Power supply stability protection for industrial control cabinets |
| 2. EM Series Industrial Protocol Gateways (IFS Compatible) | 2901527 | EM-RS485-GATEWAY-IFS | Protocol:RS485; Compatibility:IFS series; Communication mode:Serial-to-IFS data transmission; DIN rail mount | RS485 device integration into IFS systems; Field bus data interaction for industrial sensors/actuators |
| 2904472 | EM-PNET-GATEWAY-IFS | Protocol:Profinet; Compatibility:IFS series; High-speed Ethernet communication; Plug-and-play | Profinet device connection to IFS systems; High-speed data transmission for automation production lines | |
| 2297620 | EM-PB-GATEWAY-IFS | Protocol:Profibus; Compatibility:IFS series; Field bus master-slave communication; Stable data transmission | Profibus DP device integration into IFS systems; Process control system data interaction | |
| 2901528 | EM-MODBUS-GATEWAY-IFS | Protocol:Modbus RTU/ASCII; Compatibility:IFS series; Universal protocol conversion; Cost-effective | Modbus device connection to IFS systems; Remote monitoring and control of industrial equipment | |
| 2942742 | EM-MP 70 | Type:MP series functional module; Compact design; IFS system compatible; High integration | Auxiliary functional expansion for IFS systems; Custom control logic implementation for industrial scenarios | |
| 3. EMM Series 3-Channel Switch Modules (IFS Compatible) | 2908602 | EMM 3-24DC/500AC-90-EXM-IFS | Control voltage:24VDC; Load voltage:500VAC; Channel:3; Feature:Explosion-proof (EXM); Compatibility:IFS | 3-channel load switching in explosive hazardous areas; 24VDC-controlled high-voltage load management |
| 2297507 | EMM 3-230AC/500AC-IFS | Control voltage:230VAC; Load voltage:500VAC; Channel:3; Compatibility:IFS; Standard type | 3-channel AC-controlled high-voltage load switching; General industrial control cabinet power distribution | |
| 2297536 | EMM 3-230AC/500AC-16-IFS | Control voltage:230VAC; Load voltage:500VAC; Channel:3; Spec:16-series; Compatibility:IFS | Enhanced 3-channel AC load switching; High-reliability power distribution for critical industrial systems | |
| 2297497 | EMM 3-24DC/500AC-IFS | Control voltage:24VDC; Load voltage:500VAC; Channel:3; Compatibility:IFS; Standard type | 3-channel DC-controlled high-voltage load switching; PLC-controlled actuator power supply management | |
| 2297523 | EMM 3-24DC/500AC-16-IFS | Control voltage:24VDC; Load voltage:500VAC; Channel:3; Spec:16-series; Compatibility:IFS | Enhanced 3-channel DC load switching; High-stability power distribution for precision industrial equipment |
III. Nomenclature Decoding: EM/EMM Series Model Structure & Full Definition
Universal Model Format
- Voltage Monitoring Relay:
EMR-[Control Type]/[Channel]/[Function]-[Voltage] - Protocol Gateway:
EM-[Protocol]-GATEWAY-[Compatibility] - 3-Channel Switch Module:
EMM [Channel]-[Control Voltage]/[Load Voltage]-[Suffix]-[Compatibility]
Key Component & Suffix Interpretation (Critical for Selection)
- EM/EMM: Series identifier (EM for relay/gateway; EMM for 3-channel switch module)
- Function Prefix:
- EMR: Voltage monitoring relay sub-series
- MP: Functional expansion module sub-series
- Protocol Code (Gateway Models):
- RS485/PNET/PB/MODBUS: Corresponding industrial communication protocol
- IFS: Compatibility suffix, indicating matching with Phoenix IFS series systems
- Voltage Parameter (Switch Modules):
- 24DC/230AC: Control circuit voltage (DC for PLC control; AC for direct power supply control)
- 500AC: Maximum load voltage (high-voltage AC load switching capability)
- Critical Suffixes:
- EXM: Explosion-proof certification suffix (for hazardous area applications)
- 16: Enhanced performance suffix (for critical control scenarios)
- UV: Undervoltage monitoring function suffix (for EMR series)
IV. 3-Step Quick Selection Technique (100% Accurate Matching)
Follow the function demand confirmation → protocol/voltage matching → scenario selection logic to quickly lock the correct model, avoiding function mismatch and system incompatibility.
Step 1: Confirm Core Functional Demand
- Voltage stability monitoring → Select EMR-UAC/1/UV-230V (2764580)
- Heterogeneous system protocol conversion → Select EM series gateways (match protocol: RS485/PNET/PB/MODBUS)
- 3-channel high-voltage load switching → Select EMM series switch modules (2297497/2908602)
- IFS system function expansion → Select EM-MP 70 (2942742)
Step 2: Match Protocol/Voltage According to System Configuration
- Gateway protocol matching:
- Profinet network → EM-PNET-GATEWAY-IFS (2904472)
- Profibus DP network → EM-PB-GATEWAY-IFS (2297620)
- Modbus devices → EM-MODBUS-GATEWAY-IFS (2901528)
- RS485 serial devices → EM-RS485-GATEWAY-IFS (2901527)
- Switch module voltage matching:
- PLC 24VDC control → Select 24DC control models (2908602/2297497/2297523)
- Direct 230VAC control → Select 230AC control models (2297507/2297536)
Step 3: Select Suffix According to Application Scenario
- Explosive hazardous areas → Select EMM model with EXM suffix (2908602)
- Critical control systems → Select EMM model with 16 suffix (2297523/2297536)
- General industrial environments → Select standard EMM models (2297497/2297507)
- IFS system integration → Ensure all selected models have IFS compatibility suffix
V. Selection Pitfall Avoidance Guide (Critical for System Stability)
Avoid the 5 most common selection errors of the EM/EMM series to ensure functional matching, system compatibility and operational safety, eliminating control failure and equipment damage risks.
- Protocol Mismatch: Using Modbus gateway for Profinet devices → Strictly match the gateway protocol with the existing industrial network to avoid data transmission failure.
- Control Voltage Error: Using 230AC control EMM module for PLC 24DC control → Select 24DC control models to ensure normal switching of the control circuit.
- Explosion-Proof Scenario Misuse: Using standard EMM modules in hazardous areas → Select EMM model with EXM suffix (2908602) to comply with explosion-proof safety standards.
- System Compatibility Neglect: Using non-IFS models for IFS system integration → Ensure all selected models have IFS suffix to realize seamless integration with IFS systems.
- Load Capacity Underestimation: Using EMM modules for loads exceeding 500VAC → The maximum load voltage of EMM series is 500VAC; select higher-grade switch modules for over-voltage loads.
VI. Conclusion: Core Control Components for Industrial Automation Systems
The Phoenix EM/EMM series delivers a one-stop industrial control solution covering voltage monitoring, protocol conversion and load switching, with perfect compatibility with IFS systems and mainstream industrial protocols. These components are the key to realizing system integration, load management and voltage stability protection in industrial automation scenarios, effectively solving the problems of heterogeneous system communication and high-voltage load control.