Phoenix G Series & FWP/FTPC/FTP Series Industrial Wiring & Cable Components Complete Selection Guide

I. Series Overview: Industrial Terminal Blocks & Multi-Core Jumper Cables for Wiring Systems

The Phoenix G series and FWP/FTPC/FTP series are complementary industrial wiring components, designed for secure signal/power distribution and multi-core cable connection in factory automation, control cabinet wiring, and hazardous area applications. The portfolio is divided into two core categories:

  1. G Series Industrial Terminal Blocks/Distribution Modules: Includes G5 and G10 two specification series, with standard and EX (explosion-proof) variants. It supports multi-channel signal/power distribution, featuring compact design, DIN rail mounting compatibility, and explosion-proof performance for hazardous environments.
  2. FWP/FTPC/FTP Series Multi-Core Industrial Jumpers: Marked with X+1 core configuration (X=4/5/6/8/12), different series correspond to diverse cable performance:
    • FWP: High-flexibility industrial jumpers, suitable for mobile/bending scenarios (e.g., robotic arm wiring)
    • FTPC: Shielded industrial jumpers, with EMC anti-interference performance for high-noise environments
    • FTP: Standard industrial jumpers, cost-effective for general fixed wiring scenarios

All models adopt industrial-grade materials, with wide temperature tolerance (-40°C to +85°C), vibration resistance, and corrosion resistance. They seamlessly integrate with Phoenix terminal blocks, IO modules, and third-party industrial equipment, ensuring stable wiring connection in harsh environments.

Core Advantages

  1. Dual Product System Coverage: Integrates terminal distribution and multi-core cable connection, providing a one-stop solution for industrial wiring from signal distribution to device connection.
  2. Explosion-Proof Option for G Series: EX suffix models comply with explosion-proof safety standards, adapting to hazardous areas such as petroleum and chemical plants.
  3. Diversified Cable Performance for FWP/FTPC/FTP: High-flexibility, shielded, and standard variants match different installation scenarios, meeting the needs of mobile, high-noise, and general industrial environments.
  4. Standardized Compatibility: G series supports DIN rail mounting; FWP/FTPC/FTP series adopts universal connectors, compatible with mainstream industrial terminal blocks and IO modules.

II. Nomenclature Decoding: Model Structure & Key Component Interpretation

1. G Series Terminal Block Model Format

G [Specification Series]/[Core/Parameter]-[Function Suffix]

Code Segment Definition Common Options & Explanation
G Series identifier Phoenix industrial terminal block/distribution module series
Specification Series Core specification category 5 = G5 series (compact design for small-space wiring); 10 = G10 series (enhanced load capacity for medium-power distribution)
Core/Parameter Channel count or core configuration 2/3/4/5/6/12 = matching channel count for signal/power distribution
Function Suffix Special feature EX = explosion-proof certification (for hazardous area applications); No suffix = standard version

Example Decoding:

  • G 5/12-EX (2703208) = G5 series terminal block, 12-channel distribution, explosion-proof variant, for hazardous area multi-channel signal distribution
  • G 10/3 (2716716) = G10 series terminal block, 3-channel distribution, standard version, for medium-power circuit wiring

2. FWP/FTPC/FTP Series Jumper Model Format

[Series Name] [Core Configuration X+1]

Code Segment Definition Common Options & Explanation
Series Name Cable performance identifier FWP = high-flexibility; FTPC = shielded (EMC anti-interference); FTP = standard industrial grade
Core Configuration X+1 Cable core count X=4/5/6/8/12, "X+1" means X signal cores + 1 ground core (for grounding and anti-interference)

Example Decoding:

  • FWP 8+1 (3069297) = FWP high-flexibility series, 8 signal cores + 1 ground core, for mobile equipment wiring with frequent bending
  • FTPC 6+1 (3069262) = FTPC shielded series, 6 signal cores + 1 ground core, for high-noise industrial environment signal transmission

III. Complete Product Catalog: Detailed Parameter Table

Strictly aligned with your part number list, the series are categorized by G Series (Standard/Explosion-Proof) and FWP/FTPC/FTP Series for clear differentiation, with core parameters, key features and application scenarios provided for engineering and procurement reference.

Part No. Complete Model Core Parameters Key Features Application Scenarios
1. G Series Standard Terminal Blocks 2716716 G10/3 Specification:G10; Channels:3; Standard version; DIN rail mount 3-channel medium-power signal/power distribution; general industrial control cabinet wiring
  2716127 G 5/12 Specification:G5; Channels:12; Standard version; Compact design 12-channel high-density signal distribution; small-space control cabinet wiring
  2716062 G 5/ 6 Specification:G5; Channels:6; Standard version 6-channel signal distribution; cost-effective for small-scale automation systems
  2716046 G 5/ 4 Specification:G5; Channels:4; Standard version 4-channel signal distribution; sensor group wiring in general industrial scenarios
  2716033 G 5/ 3 Specification:G5; Channels:3; Standard version 3-channel signal distribution; micro-control module wiring
  2716305 G 5/ 2 B Specification:G5; Channels:2; Variant B; Compact size 2-channel signal distribution; precision instrumentation wiring
  2716020 G 5/ 2 Specification:G5; Channels:2; Standard version 2-channel signal distribution; basic control circuit wiring
  2716732 G 10/ 5 Specification:G10; Channels:5; Standard version 5-channel medium-power distribution; actuator group power supply wiring
  2716703 G 10/ 2 Specification:G10; Channels:2; Standard version 2-channel medium-power distribution; small motor control circuit wiring
2. G Series Explosion-Proof Terminal Blocks (EX) 2703208 G 5/12-EX Specification:G5; Channels:12; Explosion-proof; DIN rail mount 12-channel signal distribution in explosive hazardous areas; petroleum/chemical plant wiring
  2703198 G 5/ 6-EX Specification:G5; Channels:6; Explosion-proof 6-channel signal distribution in hazardous areas; process control system wiring
  2703185 G 5/ 4-EX Specification:G5; Channels:4; Explosion-proof 4-channel signal distribution in hazardous areas; sensor group wiring for flammable environments
3. FWP Series High-Flexibility Industrial Jumpers 3069297 FWP 8+1 Core configuration:8 signal cores +1 ground core; High-flexibility; Oil-resistant Mobile equipment wiring (robotic arms, movable sensors); scenarios requiring frequent cable bending
  3069284 FWP 6+1 Core configuration:6 signal cores +1 ground core; High-flexibility Medium-channel mobile equipment wiring; automated production line moving part connection
  3069272 FWP 5+1 Core configuration:5 signal cores +1 ground core; High-flexibility 5-channel mobile equipment wiring; small-scale robotic arm signal transmission
  3069271 FWP 4+1 Core configuration:4 signal cores +1 ground core; High-flexibility 4-channel mobile equipment wiring; compact movable actuator connection
  3069307 FWP 12+1 Core configuration:12 signal cores +1 ground core; High-flexibility 12-channel high-density mobile equipment wiring; large-scale robotic system signal transmission
4. FTPC Series Shielded Industrial Jumpers 3069264 FTPC 8+1 Core configuration:8 signal cores +1 ground core; Shielded (EMC); Anti-interference High-noise industrial environment wiring (inverters/motors nearby); precision signal transmission
  3069262 FTPC 6+1 Core configuration:6 signal cores +1 ground core; Shielded 6-channel high-noise environment wiring; process control system signal transmission
  3069260 FTPC 4+1 Core configuration:4 signal cores +1 ground core; Shielded 4-channel high-noise environment wiring; sensor signal collection near high-power equipment
5. FTP Series Standard Industrial Jumpers 3069242 FTP 8+1 Core configuration:8 signal cores +1 ground core; Standard industrial grade; Cost-effective General fixed wiring; 8-channel signal transmission for control cabinet internal modules
  3069239 FTP 6+1 Core configuration:6 signal cores +1 ground core; Standard industrial grade General 6-channel fixed wiring; actuator group signal connection
  3069241 FTP 5+1 Core configuration:5 signal cores +1 ground core; Standard industrial grade General 5-channel fixed wiring; medium-scale control system wiring
  3069223 FTP 4+1 Core configuration:4 signal cores +1 ground core; Standard industrial grade General 4-channel fixed wiring; basic control circuit connection
  3069255 FTP 12+1 Core configuration:12 signal cores +1 ground core; Standard industrial grade General 12-channel fixed wiring; high-density control cabinet module interconnection

IV. 3-Step Quick Selection Technique

Follow this simple logic to quickly lock the optimal model for your application, avoiding functional mismatch and installation errors.

Step 1: Confirm Product Category by Demand

  • Signal/power distribution in control cabinets/hazardous areas → Select G series terminal blocks
    • Hazardous area application → Must select EX suffix explosion-proof models
    • Medium-power distribution → Select G10 series; high-density small-space wiring → Select G5 series
  • Multi-core cable connection between devices → Select FWP/FTPC/FTP series jumpers
    • Mobile/bending scenarios → Select FWP high-flexibility series
    • High-noise environments → Select FTPC shielded series
    • General fixed wiring → Select FTP standard series (cost-effective)

Step 2: Match Core/Channel Count According to System Requirements

  • G series: Calculate the number of signal/power channels to be distributed, select models with equal or slightly more channels (reserve 1–2 spare channels for future expansion)
  • FWP/FTPC/FTP series: Confirm the number of signal cores required by the device, select the corresponding X+1 core configuration (ensure the ground core is available for grounding protection)

Step 3: Verify Installation Compatibility

  • G series: Confirm the mounting rail is NS 35/7.5 standard DIN rail to avoid installation size mismatch
  • FWP/FTPC/FTP series: Verify the connector type matches the terminal block/IO module interface of the connected device to ensure stable plug-in connection

V. Selection Pitfall Avoidance Guide (Critical for System Stability)

Avoid the 4 most common selection errors of the series to ensure reliable operation in industrial environments.

  1. Explosion-Proof Scenario Misuse: Using standard G series models in explosive hazardous areas → Select EX suffix explosion-proof models to comply with safety regulations and prevent safety accidents.
  2. Cable Type Misapplication: Using FTP standard jumpers for robotic arm mobile wiring → Select FWP high-flexibility models to avoid cable breakage and signal interruption caused by frequent bending.
  3. Anti-Interference Neglect: Using non-shielded jumpers in high-noise environments → Select FTPC shielded models to suppress electromagnetic interference and ensure signal integrity.
  4. Channel Count Underestimation: Selecting 4-channel G series models for 6-channel sensor distribution → Reserve 20% spare channels during selection to facilitate future system expansion.

VI. Conclusion: Core Wiring Components for Industrial Automation Systems

The Phoenix G series and FWP/FTPC/FTP series deliver a comprehensive industrial wiring solution covering signal/power distribution and multi-core cable connection. The G series meets the distribution needs of general and hazardous areas with its explosion-proof option and dual-specification design, while the FWP/FTPC/FTP series adapts to diverse connection scenarios with differentiated cable performance.

Phoenix G Series & FWP/FTPC/FTP Series Industrial Wiring & Cable Components Complete Selection Guide

Created on:2026-01-05 10:37

News Dynamics

NEWS