In industrial circuit control, signal transmission and equipment protection scenarios, Phoenix PT series components are widely trusted for their flexible specification configuration, wide voltage adaptation range and reliable industrial-grade performance. This guide collates the product codes, models and detailed descriptions of PT series models, helping electrical design, procurement and maintenance personnel quickly select suitable products for different industrial control system requirements.

1. PT Series Core Model List (With Product Descriptions)

Product Code Product Model Product Description
2839282 PT-BE/FM PT series basic component, BE standard structure, FM safety certification, compliant with international industrial safety standards, suitable for general circuit control scenarios with certification requirements
2839363 PT4X1-BE PT series 4×1 multi-channel configuration component, BE basic structure design, supporting parallel control of 4 groups of single-channel circuits, ideal for dense wiring industrial control systems
2839208 PT2X2-BE PT series 2×2 dual-group dual-channel component, BE standard structure, suitable for synchronous control scenarios of two groups of dual-channel circuits
2800457 PT2-PE/S-24AC/FM PT series 2-spec component, with PE/S protection grounding function, 24V AC working voltage, FM certified, enhancing circuit safety in AC control systems
2856265 PT PE/S+1X2-BE PT series component with PE/S protection grounding function, 1×2 single-group dual-channel configuration, BE basic structure, suitable for small-signal circuit protection and control
2819008 PT PE/S+1X2-24-ST PT series component with PE/S protection grounding function, 1×2 channel configuration, 24V working voltage, ST standard installation structure, suitable for 24V system circuit protection
2906002 PT 5-HF-24DC-ST PT series 5-spec component, HF high-frequency signal adaptation, 24V DC working voltage, ST standard installation, designed for high-frequency DC control circuit scenarios
2838775 PT 5-HF-12 DC-ST PT series 5-spec component, HF high-frequency compatibility, 12V DC working voltage, ST standard structure, suitable for low-voltage high-frequency signal control systems
2838762 PT 5-HF- 5 DC-ST PT series 5-spec component, HF high-frequency function, 5V DC ultra-low voltage adaptation, ST standard installation, ideal for micro-current high-frequency circuit control
2858014 PT 4X1-48DC-ST PT series 4×1 multi-channel component, 48V DC working voltage, ST standard installation structure, suitable for medium-voltage DC multi-channel control scenarios
2838322 PT 4X1-24DC-ST PT series 4×1 channel component, 24V DC mainstream industrial voltage, ST standard installation, compatible with most 24V DC control systems
2838351 PT 4X1-24AC-ST PT series 4×1 multi-channel component, 24V AC working voltage, ST standard structure, suitable for AC 24V multi-circuit parallel control
2838319 PT 4X1-12DC-ST PT series 4×1 channel component, 12V DC working voltage, ST standard installation, ideal for low-voltage DC multi-signal control scenarios
2838348 PT 4X1-24AC-ST PT series 4×1 multi-channel component, 24V AC voltage adaptation, ST standard structure, suitable for AC system multi-circuit control
2838306 PT 4X1- 5DC-ST PT series 4×1 channel component, 5V DC ultra-low voltage, ST standard installation, designed for micro-power multi-channel signal control systems
2839486 PT 4-EX(I)-BE PT series 4-spec component, EX(I) explosion-proof grade with fault indicator, BE basic structure, suitable for hazardous environment circuit control scenarios
2839402 PT 4-BE PT series 4-spec basic component, BE standard structure, compact size, cost-effective choice for general 4-spec circuit control
2839240 PT 4-24DC-ST PT series 4-spec component, 24V DC working voltage, ST standard installation structure, suitable for mainstream 24V DC industrial control circuits
2800078 PT 4-24AC-ST PT series 4-spec component, 24V AC voltage adaptation, ST standard installation, ideal for AC 24V circuit control scenarios
2839237 PT 4-12DC-ST PT series 4-spec component, 12V DC working voltage, ST standard structure, suitable for low-voltage DC 4-spec circuit control
2839415 PT 4+F-BE PT series 4-spec component with +F enhanced function, BE basic structure, improving circuit control precision and stability, suitable for high-demand control scenarios

2. Quick Interpretation of PT Series Model Naming Rules

Mastering the naming logic can help you quickly identify the core parameters and applicable scenarios of the product:

  1. Series Prefix: PT = Phoenix dedicated industrial control component series, focusing on circuit control, signal transmission and protection.
  2. Specification & Channel Configuration:
    • 4X1/2X2/1X2: Multi-channel configuration codes, representing 4 groups of single-channel, 2 groups of dual-channel and 1 group of dual-channel respectively, determining the circuit control quantity.
    • 5/4/2: Core specification parameters of the component, determining the current-carrying capacity and signal adaptation range of the product.
  3. Function Suffix Mark:
    • BE: Basic structure type, standard configuration, suitable for general control scenarios.
    • FM: FM safety certification mark, complying with international industrial safety standards, suitable for export-oriented or high-safety-requirement equipment.
    • PE/S: Protection grounding function, enhancing the electrical safety of the circuit, suitable for equipment with grounding requirements.
    • HF: High-frequency signal adaptation function, designed for high-frequency circuit control scenarios.
    • EX(I): Explosion-proof grade with fault indicator, suitable for hazardous industrial environments with flammable and explosive risks.
    • +F: Enhanced function configuration, improving control precision and stability, suitable for high-demand control scenarios.
    • ST: Standard installation structure, compatible with Phoenix standard mounting rails and accessories, facilitating quick assembly.
  4. Working Voltage Specification:
    • The voltage value in the model (24AC/24DC/12DC/5DC/48DC) represents the rated working voltage of the component, covering AC and DC voltage systems to match different industrial power supplies.

3. Core Advantages of Phoenix PT Series Components

  1. Diversified Channel & Specification ConfigurationCovers multi-channel configurations (4X1/2X2/1X2) and core specifications (5/4/2), meeting the control needs of single-signal, multi-signal parallel and group synchronous control scenarios in industrial systems.
  2. Wide Voltage Adaptation RangeSupports working voltages from 5V DC to 48V DC and 24V AC, matching low-voltage micro-signal circuits, mainstream industrial 24V systems and medium-voltage control circuits, with strong versatility.
  3. Rich Extended Function SupportIntegrates protection grounding (PE/S), high-frequency adaptation (HF), explosion-proof (EX(I)), safety certification (FM) and enhanced control (+F) functions, adapting to complex industrial application scenarios.
  4. Strong Compatibility & Easy InstallationThe ST standard installation structure is compatible with Phoenix's mounting rails and accessories, occupying small space in the control cabinet, suitable for dense wiring environments, and realizing quick plug-in and replacement.
  5. Industrial-grade Reliable PerformancePasses strict high-temperature, high-humidity and vibration resistance tests, with stable operation in harsh industrial environments, ensuring long-term reliable work of the control system.

4. Product Selection Suggestions

  1. Channel & Specification MatchingDetermine the number of controlled circuits and current load requirements first: select 4X1/2X2 multi-channel models for multi-circuit parallel control; choose 5-spec models for high-current control scenarios; select 2-spec models for micro-signal circuits.
  2. Function Selection Based on Scenarios
    • For hazardous environments: Prioritize models with EX(I) explosion-proof suffix.
    • For high-frequency signal control: Select models with HF suffix.
    • For circuits with grounding requirements: Choose models with PE/S protection grounding function.
    • For export or high-safety-requirement scenarios: Select models with FM certification.
    • For high-precision control needs: Adopt models with +F enhanced function.
  3. Voltage Adaptation ConfirmationMatch the component's working voltage with the on-site power supply system: select DC voltage models (24DC/12DC/5DC) for DC control systems; choose AC voltage models (24AC) for AC circuit control scenarios.
  4. Installation & Cost OptimizationFor compact control cabinets: Select models with ST standard installation structure for space-saving; for general non-critical circuits: Choose basic BE structure models without additional functions to reduce procurement costs.