Phoenix SUBCON-PLUS-CAN/SC2-D-SUB bus connector 2708999,D-SUB connector, 9-position socket, two 35-degree cable outgoing lines to two rows of terminals, bus system: CAN, CANopen, SafetyBUS P, maximum transmission speed of 1 Mbps, terminal resistance can be connected through sliding switch, pin distribution: 2, 3, 7, 9; Screw terminal

Application Description
Application Description for industrial applications only
Use Restrictions
CCCex Description is not permitted in China for use in potentially explosive areas.

Product Type Data plug
MTTF 6706 years (SN 29500 standard, temperature 25°C, duty cycle 21%)
1817 years (SN 29500 standard, temperature 40°C, duty cycle 34.25%)
155 years (SN 29500 standard, temperature 40°C, duty cycle 100%)
Pin Distribution 2, 3, 7, 9

Rated voltage UN 5V
Rated current IN 100 mA
transmission medium copper cable

D-SUB connection
Connection Mode D-SUB socket
PCB Connection
Connection Mode screw connection
stripping length 5mm
Minimum cross section of rigid conductor 0.14 mm²
Maximum cross section of rigid conductor 1.5 mm²
Minimum cross section of flexible lead 0.14 mm²
Flexible lead maximum cross section 1 mm²
Single Wire/End Point, Minimum Rigid AWG 26
single wire/wiring point, maximum rigid AWG 16
AWG Wire Minimum Cross Section, Flexible 26
AWG stranded wire, flexible 18

bus system CAN, CANopen, SafetyBus-P
signal CAN
CANopen®
SafetyBUS p

Dimensional drawing
width 16.6mm
height 39.4mm
length 58mm

Identification Material (Shell) ABS (metal plating)

Cable outer diameter 7.6mm... 8.4mm (bus line incoming)

Mechanical parameters
Insertion/unplugging cycle > 200

meets EN 60068-2-6/IEC 60068-2-6 anti-vibration standards vibration (running): 5g,10 ... 150Hz, 2.5 h, XYZ direction
Conforms to EN 60068-2-27/IEC 60068-2-27 impact resistance standards impact force (operation): 15g,11 ms, half-sine shock pulse

environmental conditions
protection level IP40
ambient temperature (operation) -20°C ... 75°C
ambient temperature (storage/transport) -25°C ... 80°C
elevation ≤ 5000 m (see manufacturer's statement for high altitude operation for limits)
Allowable humidity (operating) 10%... 95% (non-condensing)
Allowable humidity (storage/transportation) 5%... 95% (non-condensing)
2708232

Phoenix SUBCON-PLUS-CAN/SC2-D-SUB Bus Connector 2708999

Product Center