Phoenix PT 2X1-VF-230AC-surge protector 2805460, rail-mounted surge protector, used for high-voltage signal protection. The protection circuit has no leakage current and is used to protect 2 floating ground signals. Rated voltage: 230VAC

Product Type measurement and control technology
Product Series PLUGTRAB PT
IEC Category C1
C2
C3
D1
type DIN rail module, split, detachable
Bits 2

Rated voltage UN 230V AC
indicator/remote signaling
switching function normally closed contact
Maximum operating voltage Umax.AC 250V AC
Maximum operating current Imax 1 A

Connection Mode screw connection
thread M3
Tightening torque 0.8 Nm
Flexible Wire Cross Section 0.2 mm² ... 2.5 mm²
Rigid conductor cross section 0.2 mm² ... 4 mm²
Connectable Guide Cross Section AWG 24 ... 12

Dimensional drawing
width 17.7mm
height 90mm
depth 51.7mm
Horizontal stitch pitch 1 Partition
full module width 17.7mm
Full module height 90mm
full module depth 65.5mm

color black (RAL 9005)
flame retardant rating, according to UL 94 V-0
Shell Material PA 6.6

Mechanical parameters
Open Side Panel No

Direction of action Line-Line & Line-Earth Ground
Maximum continuous voltage Uc 250V AC
Rated current 6 A
UC, the effective working current IC ≤ 2 µA
Residual Flow IPE ≤ 2 µA (UN)
Nominal discharge current In(8/20) µs 3 kA
Rated discharge current In(8/20)& micro;s (core-ground) 3 kA
pulse discharge current Iimp(10/350) µs 500 A
Total discharge current Itotal(8/20) µs 8 kA
Total discharge current Itotal(10/350) µs 1 kA
Maximum discharge current Imax(8/20)µs 8 kA
Maximum discharge current Imax(8/20) & micro;s (core-ground) 8 kA
rated power pulse current lan (1000)& micro;s (core-ground) 100 A
Output voltage limit 1 kV/& micro;s (core-ground) static ≤ 1.4 kV
Residual voltage ln,(wire-wire) ≤ 2 kV
Residual voltage ln,(wire-ground) ≤ 1 kV
Residual voltage lan(10/1000)& micro;s (wire-wire) ≤ 1.4 kV
Ian(10/1000)& micro; Residual pressure at s (line-ground) ≤ 700V
Maximum absorbed energy (2 ms) 150 J
voltage protection level Up(core-core) ≤ 2.5 kV (C2 - 4 kV / 2 kA)
≤ 1.8 kV (C3 - 100 A)
≤ 2.6 kV (D1 - 500 A)
voltage protection level Up(line-ground) ≤ 1.1 kV (C1 - 500 A)
≤ 1.5 kV (C2 - 4 kV / 2 kA)
≤ 1.6 kV (C3 - 100 A)
≤ 1.8 kV (D1 - 500 A)
response time tA ≤ 100 ns
capacitance (core-core) Typical 4.5 pF
capacitance (core-ground) Typical 9 pF
the resistance of each path 0 Ω
Surge protection fault alarm None
6 A (gL/gG)
Impact resistance (line-ground) C2 - 4 kV / 2 kA
C3 - 100 A
D1 - 500 A
2805460

Phoenix PT 2X1-VF-230AC-Surge Protector 2805460