Phoenix PSR-SCP- 24DC/FSP2/2X1/1X2-coupling relay 2986575, safety coupling relay, suitable for SIL 2 high-demand and low-demand applications, can connect digital output signals to peripherals, 2 enable current paths, 1 Signal contact, suitable for safe state shutdown application module, built-in test pulse filter, plug-in screw connection, width: 17.5mm
Application Description | |
Application Description | for industrial applications only |
Product Type | coupling relay |
Product Series | PSRclassic |
Application | Safety Shutdown |
high requirements | |
low requirements | |
control | single channel |
mechanical life | 10x 106Switch Times |
Relay Model | Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3 |
rated conditions | 2.4W |
Rated operating mode | 100% Eligible |
Electrical clearance and creepage distance between power supply circuits | |
Rated insulation voltage | 250V AC |
rated overvoltage/insulation | control circuits A1/A2), (31/32), (13/14), 23/24 6 kV |
Overview | |
Rated control circuit supply voltage US | 24V DC -15 % / +10% |
US | Typical 1.32W |
Rated control supply current IS | 55 mA typical |
Input Voltage Range | 20.4V DC ... 26.4V DC |
Impulse current | Max. 100 mA |
delay time | max. 5 ms (at A1, at the voltage dip Us) |
max. 2 ms (test pulse width; high test pulse at A1/A2) | |
≥ 100 ms (test pulse width; high test pulse at A1/A2) | |
test pulse rate = 80 x test pulse width | |
max. 5 ms (test pulse width; low test pulse at A1/A2) | |
≥ 50 ms (test pulse rate; low test pulse at A1/A2) | |
test pulse rate = 15 x test pulse width | |
Typical startup time (Us) | 50 ms |
Typical release time | 50 ms |
Recovery Time | 1 s |
Maximum switching frequency | 0.5Hz |
protection circuit | Surge protection; Suppressor diode, 33V (A1-A2) |
Operating voltage display | 1 x yellow LED |
Contact Type | 2 normally open safety contact outputs |
1 feedback loop | |
Contact Material | AgCuNi,+ 0.2 µm Au |
maximum switching voltage | 250V AC/DC (normally open contact, normally closed contact, pay attention to the load curve) |
Minimum Switching Voltage | 15V AC/DC (normally open contact/normally closed contact) |
limit continuous current | 5 A (N/O contact, note attenuation) |
100 mA (normally closed contact) | |
Maximum starting current | 5 A (N/O contact) |
100 mA (normally closed contact) | |
Minimum impulse current | 5 mA (normally open contact/normally closed contact) |
the square of the total current value | 50 A2(note the reduced value) |
Maximum power rating (resistive load) | 120W (24V DC,& tau;= 0ms, normally closed contact: 2.4W) |
192W (48V DC,& tau;= 0ms, normally closed contact: 4.8W) | |
162W (60VDC,& tau; = 0ms, normally closed contact: 6W) | |
66W (110V DC,& tau;= 0ms, normally closed contact: 11W) | |
60W (220V DC,& tau;= 0ms, normally closed contact: 22W) | |
1250 VA (250V AC,& tau; = 0 ms, normally closed contact: 25VA) | |
Maximum power rating (inductive load) | 72W (24V DC,& tau;= 40ms, normally closed contact: 2.4W) |
43W (48V DC,& tau;= 40ms, normally closed contact: 4.8W) | |
41W (60VDC,& tau; = 40ms, normally closed contact: 6W) | |
35W (110V DC,& tau;= 40ms, normally closed contact: 11W) | |
48W (220V DC,& tau;= 40ms, normally closed contact: 22W) | |
on-off capacity | 75 mW minimum |
on-off capacity (3600/h cycle) | 5 A (24V (DC13)) |
5 A (230V (AC15)) | |
output fuse | 10 A gL/gG (N/O contact) |
4 A gL/gG (for low-demand applications) | |
150 mA fast fuse (normally closed contact) |