Phoenix VS-OE-OE-93B/1000,0-Data Cable 1403891, Available in Meters, Data Cable, PROFINET CAT5 (100 Mbps), EtherCAT® CAT5 (100 Mbps), Shielded, PVC/PVC, Green RAL 6018, 4-Core (1 x4xAWG22/7,SF/TQ), Color Single Core: White, Yellow, Blue, Orange, Cable Length: 1000 m
| Product Type |
Data cable supplied by meter |
| Sensor Type |
PROFINET |
| Bits |
4 |
| Shielding |
have |
| Rated voltage UN |
48V AC |
| 60V DC |
| transmission medium |
copper cable |
| Signal Type/Classification |
PROFINET CAT5 (IEC 11801:2002), 100 Mbps |
| Cable Length |
1000 m |
| PROFINET PVC strand CAT5 [93B] |
| Dimensional drawing |
|
| Cable Weight |
67 kg/km |
| UL AWM |
21694 |
| Bits |
4 |
| Shielding |
have |
| Cable Type |
PROFINET PVC strand CAT5 [93B] |
| Wire Structure |
1x4xAWG22/7,SF/TQ |
| signal running time |
5.3 ns/m |
| Signal Speed |
0.66 c |
| wire structure signal line |
7x 0.25mm |
| AWG, signal wire |
22 |
| Wire Cross Section |
4x 0.34 mm² |
| wire diameter, including insulation |
1.55mm |
| Cable outer diameter |
6.50mm ± 0.2mm |
| outer sheath, material |
PVC |
| outer sheath, color |
Green RAL 6018 |
| Wire Material |
tinned copper stranded wire |
| wire insulation material |
PE |
| single line, color |
white, yellow, blue, orange |
| thickness, outer sheath |
approx. 0.90mm |
| Total Strand |
Star-twisted four-line group |
| Cable Shielding Cover |
85% |
| insulation resistance |
≥ 500 MΩ*km |
| coupling resistance |
≤ 20.00 mΩ/m (10 MHz) |
| Loop Resistance |
≤ 120.00 Ω/km |
| wave impedance |
100 Ω ±15 Ω (100 MHz) |
| Rated voltage, cable |
600V |
| Core test voltage/core |
2000V (50 Hz,1 min) |
| core test voltage/shield |
2000.00V (50 Hz,1 min) |
| minimum bending radius, fixed installation |
3 x D |
| minimum bending radius, movable installation |
7 x D |
| minimum bending radius, fixed mounting |
20mm |
| minimum bending radius, mobile installation |
46mm |
| Near End Crosstalk Attenuation (NEXT) |
80 dB (1 MHz) |
| 76 dB (4 МHz) |
| 70 dB (10 MHz) |
| 65 dB (16 MHz) |
| 63 dB (20 МHz) |
| 60 dB (31.25 МHz) |
| 55 dB (62.5 МHz) |
| 50 dB (100 MHz) |
| Shielding Attenuation |
2.1 dB (1 MHz) |
| 4 dB (4 МHz) |
| 6.3 dB (10 MHz) |
| 8 dB (16 MHz) |
| 9 dB (20 МHz) |
| 11.4 dB (31.25 МHz) |
| 16.5 dB (62.5 МHz) |
| 21.3 dB (100 MHz) |
| flame retardant |
meets UL 1685(CSA FT 4) |
| oil resistance |
can be oil-proof to a certain extent |
| Other protective functions |
UV Protection (Compliant with UL 1581, Part 1200) |
| ambient temperature (operation) |
-40°C ... 70°C (cable, fixed installation) |
| -40°C ... 70°C (cable, movable installation) |
| ambient temperature (installation) |
-20°C ... 60°C |