Phoenix DT-TELE-RJ45-surge protector 2882925, surge protection socket, used for the protection of analog and digital telecommunications interfaces (VDSL up to 50 Mbps). Connection: RJ45(RJ12/RJ11) and COMBICON plug-in screw connector. Alternatively, it can be attached to the DIN rail.

Product Type Information Technology
product series DATATRAB
IEC Category B2
C1
C2
C3
D1
type adapter for DIN rail mounting
Bits 4
line pairs per module 2
insulation characteristics
Overvoltage Category II
pollution level 2

Connection Mode RJ45 / COMBICON
thread M2
Tightening torque 0.22 Nm
Flexible Wire Cross Section 0.14 mm² ... 1.5 mm²
Rigid conductor cross section 0.14 mm² ... 1.5 mm²
Attachable Guide Cross Section AWG 28 ... 16

Dimensional drawing
width 25mm
height 102mm
depth 63.5mm

color silver
black (RAL 9005)
Shell Material zinc die casting

Mechanical parameters
Open Side Panel No

movement direction Line-Line & Line-Ground/Shield
Maximum continuous voltage Uc 185V DC
130V AC
Rated current ≤ 380 mA (25 °C)
UC, the effective working current IC ≤ 6 µA
Residual Flow IPE ≤ 4 µA
Nominal discharge current In(8/20) & micro;s (core-core) ≤ 5 kA
Rated discharge current In(8/20)& micro;s (core-ground) ≤ 5 kA
Total discharge current Itotal(8/20) µs 10 kA
rated power pulse current lan (1000)& micro;s (core-core) 100 A
rated power pulse current lan (1000)& micro;s (core-ground) 100 A
rated power pulse current lan (700)& micro;s (core-core) 150 A
rated power pulse current lan (700)& micro;s (core-ground) 150 A
Output voltage limit 1 kV/& micro;s (core-core) static ≤ 250V
Output voltage limit 1 kV/& micro;s (core-ground) static ≤ 250V
Residual voltage ln,(wire-wire) ≤ 120V
Residual voltage ln,(wire-ground) ≤ 120V
voltage protection level Up(core-core) ≤ 250V (B2 - 4 kV / 100 A)
≤ 250V (C1 - 1 kV / 500 A)
≤ 250V (C2 - 10 kV / 5 kA)
voltage protection level Up(line-ground) ≤ 250V (B2 - 4 kV / 100 A)
≤ 250V (C1 - 1 kV / 500 A)
≤ 250V (C2 - 10 kV / 5 kA)
response time tA(core-core) ≤ 100 ns
response time tA (core-ground) ≤ 100 ns
input attenuation AE, symmetric. Typical 0.5 dB (≤ 5 MHz / 100 Ω)
Typical 0.3 dB (≤ 8 MHz/150 Ω)
Typical 0.3 dB (≤ 2.5 MHz / 600 Ω)
cut-off frequency fg(3 dB),100 Ω symmetric system Typical 50 MHz
capacitance (core-core) Typical 20 pF (f = 1 MHz / VR = 0V)
capacitance (core-ground) Typical 20 pF (f = 1 MHz / VR = 0V)
the resistance of each path 3.3 Ω 10%
Surge protection fault alarm None
Impact tolerance (line-line) B2 - 4 kV / 100 A
C1 - 1 kV / 500 A
C2 - 10 kV / 5 kA
Impact resistance (line-ground) B2 - 4 kV / 100 A
C1 - 1 kV / 500 A
C2 - 10 kV / 5 kA
D1 - 1 kA