Phoenix MACX MCR-EX-T-UI-UP-temperature measurement transmitter 2865654, freely programmable inntrically safe temperature measurement transmitter, with analog output and 1 threshold relay, standard configuration, 2-, 3-or 4-wire resistance thermometer, thermocouple, galvanic isolation, wide-range power supply, screw connection, SIL,PL.
| Product Type |
temperature measurement transmitter |
| product series |
MACX Analog |
| Model |
Ex I Isolation Amplifier with SIL and PL Functional Safety |
| configuration |
DIP switch |
| Software |
| insulation characteristics |
| Overvoltage Category |
II |
| pollution level |
2 |
| Function |
| configuration |
DIP switch |
| Software |
| electrical isolation |
4 road isolation |
| step response (0-99%) |
≤ 1.75 s (SIL on) |
| 1.3 s (SIL off) |
| maximum temperature coefficient |
0.01 %/K |
| Maximum transmission error |
0.1 % (for example, when Pt 100,300 K minimum range) |
| Electrical isolation input/output/power supply |
| Test Voltage |
2.5 kV AC (50 Hz, 60 s) |
| electrically isolated input/output |
| electrical isolation |
375V (peak according to IEC/EN 60079-11) |
| galvanically isolated input/power supply |
| electrical isolation |
375V (peak according to IEC/EN 60079-11) |
| galvanically isolated input/switch output |
| electrical isolation |
375V (peak according to IEC/EN 60079-11) |
| galvanically isolated output/power |
| Rated insulation voltage |
300Vrms |
| insulation |
safety isolation conforming to IEC/EN 61010-1 |
| power supply |
| Rated supply voltage range |
24V AC/DC ... 230V AC/DC -20 % ... +10 % (50/60 Hz) |
| Supply Voltage Range |
19.2V AC/DC ... 253V AC/DC (50/60 Hz) |
| Typical current consumption |
< 50 mA (24V DC) |
| power consumption |
< 1.5W |
| signal |
| Input Number |
1 |
| input signal |
temperature |
| resistance |
| voltage |