Phoenix PLC-RPT-230UC/21-21AU/RWF-Relay module 2900345, suitable for PLC-INTERFACE in rail transit applications, including base terminals, using plug-in connection and with plug-in miniature multi-layer gold-plated contact relay, range: 0.75 x UN to 1.15 x UN, rated input frequency 16.7Hz,2 PDT, input voltage 230V AC

Product Type Relay Module
Product Series PLC-INTERFACE
Application Railway applications
Mode of operation 100% operating factor
mechanical life approx. 3x 107times
insulation characteristics: electrical clearance and creepage distance between power supply circuits
insulation Foundation Isolation
Overvoltage Category III
pollution level 2
Data Management Status
Last data maintenance date 21.03.2025

rated conditions 1.1W
test voltage (coil/contact) 6 kV (50Hz,1 min, coil/contact)
Electrical clearance and creepage distance between power supply circuits
Rated insulation voltage 250V AC
Rated overvoltage 6 kV

coil side
Rated input voltage UN 230V AC
Input Voltage Range 172.5V AC ... 264.5V AC (20 °C)
rated voltage ("hot" plug electromagnetic relay) 110V DC
mains frequency 16.67Hz
drives and functions monostable
drive (polarity) polarization
UN 4.8 mA (AC)
Typical Response Time 20 ms
Typical release time 60 ms
protection circuit Bridge Rectifier
Operating voltage display yellow LED

switching
Contact Type 2 changeover contacts
Switch Contact Type single contact
Contact Material AgNi, hard gold plating
Considerations if the maximum upper limit value is exceeded, the gold plating layer is destroyed. At this time, the threshold of AgNi contact material is in effect, but the service life may be shortened.
maximum switching voltage 30V AC
36V DC
Minimum Switching Voltage 100 mV
limit continuous current 50 mA
Maximum impact current 50 mA
minimum switching current 1 mA
Maximum power rating (resistive load) 1.2W (24V DC)
switch capacity 2 A (24V(DC13) to DIN VDE 0660/IEC 60947)
0.2 A (220V DC / 230V AC(DC13) according to DIN VDE 0660/IEC 60947)
3 A (220V DC / 230V AC(AC15) according to DIN EVDE 0660/IEC 60947)
switching: when the gold plating layer is destroyed
Considerations If the gold plating is damaged, the following values are applicable.
Contact Material AgNi
maximum switching voltage 250V AC/DC (When the voltage between the same terminal blocks of two adjacent modules is greater than 250V(L1, L2, L3), the partition PLC-ATP must be used.)
Minimum Switching Voltage 5V AC/DC
limit continuous current 6 A
Maximum impact current 8 A
minimum switching current 10 mA
2967060

Phoenix PLC-RPT-230UC/21-21AU/RWF-RELAY MODULE 2900345