Phoenix MCR-S-20-100-UI-DCI-current transmitter 2908798,MCR current measurement transmitter, programmable and configurable, can measure DC, AC and distortion current, input current 0...20 to 0...100 A, unconfigured

Product Type Current transmitter
insulation characteristics
Overvoltage Category III
pollution level 2

total error ≤ 1.5 % (temperature range)
rated conditions 2.2W
Measurement Level III
test voltage, output/power supply 500V AC (50 Hz, 60 s)
test voltage, input/output 4 kV AC (50 Hz, 60 s)
test voltage, input/power supply 4 kV AC (50 Hz, 60 s)
protection circuit surge protection; 33V suppressor diode
step response (10-90%) 330 ms (AC)
40 ms (DC)
temperature coefficient, typical < 0.025 %/K
Maximum transmission error < 0.5 % (at rated state, within rated range)
Rated insulation voltage 300V AC (ground)
Power
Supply Voltage Range 20V DC ... 30V DC
Maximum current consumption < 40 mA (no load)

measurement
configurable/programmable Yes, not configured
Input current range 0 A AC/DC ... 100 A AC/DC (Permissible continuous overload: 120%)
minimum input current 0 A AC/DC ... 19 A AC/DC
maximum input current 0 A AC/DC ... 100 A AC/DC
LSB: Current 1 &micro;A (1 A)
2 &micro;A (2 A)
5 &micro;A (5 A)
10 &micro;A (10 A)
50 &micro;A (50 A)
100 &micro;A (100 A)
Overload depends on the wire connected by the perforation.
surge strength depends on the wire connected by the perforation.
Frequency measurement range 15Hz ... 400Hz
Curve Type AC, DC, or distorted current
Operating Threshold 1% (rated value of measuring range 100 A)

signal: current/voltage
configurable/programmable Yes, not configured
voltage output signal 0V ... 10V
5V ... 1V
5V ... -5V
2V ... 10V
-10V ... 10V
0V ... 5V
1V ... 5V
-5V ... 5V
10V ... 0V
10V ... 2V
10V ... -10V
5V ... 0V
current output signal 0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
load/output load voltage output > 10 kΩ
load/output load current output < 500 Ω