Phoenix TTC-6P-3-24DC-PT-I-surge protector 1061383, surge protection, including protective plug and base element, built-in status indicator, 3-wire floating ground signal circuit for high rated current, suitable for Ex e certification in Zone 2, HART compatible. Can be used in safety-related circuits up to SIL 3.

Product Type measurement and control technology
Product Series TERMITRAB complete
IEC Category C1
C2
C3
D1
type DIN rail module, split, detachable
insulation characteristics
Overvoltage Category III
pollution level 2

Rated voltage UN 24V DC

Connection Mode in-line connection
Flexible Wire Cross Section 0.2 mm² ... 2.5 mm²
Rigid conductor cross section 0.2 mm² ... 4 mm²
Attachable Guide Cross Section AWG 24 ... 12

Maximum input current 5 A (55 °C)
Maximum input voltage 30V DC
elevation ≤ 2000 m (amsl)
ambient temperature (operation) -40°C ... 80°C (T4)

Dimensional drawing
width 6.2mm 0.1mm
height 105.8mm
depth 100 mm (7.5mm with DIN rail)

color (basic element) gray (RAL 7042)
color (pin connector) light gray (RAL 7035)
flame retardant rating, according to UL 94 V-0
insulation material PBT
Shell Material PBT

Mechanical parameters
Open Side Panel No

movement direction Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Maximum continuous voltage Uc 30V DC
21V AC
Rated current 5 A (55 °C)
UC, the effective working current IC ≤ 5 µA
Residual Flow IPE ≤ 1 µA
Nominal discharge current In(8/20) & micro;s (core-core) 0.5 kA
Rated discharge current In(8/20)& micro;s (core-ground) 5 kA
pulse discharge current Iimp(350) & micro;s (core-ground) 0.5 kA
Total discharge current ITotal(8/20) µs 10 kA
voltage protection level Up(core-core) ≤ 68V (C1 - 1 kV / 500 A)
≤ 50V (C3 - 100 A)
≤ 50V (C3 - 25 A)
voltage protection level Up(line-ground) ≤ 700V (C1 - 1 kV / 500 A)
≤ 900V (C2 - 10 kV / 5 kA)
2906815