Phoenix PLT-SEC-T3-230-P-UT/PT-3 type surge protector-plug 2907923, spare plug, used for PLT-SEC-...-UT/PT product series 2/3 type surge protection. Rated voltage 230V.
| Product Type | Spare Plug |
| product series | SEC Family |
| IEC power supply system | TN-S |
| TT | |
| type | needle type |
| Bits | 2 |
| Surge protection fault alarm | with visual status indication window |
| insulation characteristics | |
| Overvoltage Category | III |
| pollution level | 2 |
| IEC Category | II / III |
| T2 / T3 | |
| EN Type | T2 / T3 |
| Ports | One |
| Connection Mode | pluggable |
| Dimensional drawing | |
| width | 17.5mm |
| height | 46.7mm |
| depth | 65.7mm |
| Horizontal stitch pitch | 1 Partition |
| color | light gray (RAL 7035) |
| gray (RAL 7042) | |
| flame retardant rating, according to UL 94 | V-0 |
| material | 600 |
| insulation material | PA 6.6-FR 20 % GF |
| PA 6.6-FR | |
| Shell Material | PA 6.6-FR 20 % GF |
| PA 6.6-FR |
| protection channel | L-N |
| L-PE | |
| N-PE | |
| movement direction | 1L-N & N-PE |
| Rated voltage UN | 240V AC (TN-S) |
| 240V AC (TT) | |
| Rated frequency fN | 50Hz (60 Hz) |
| Maximum continuous voltage Uc | 264V AC |
| Residual Flow IPE | ≤ 5 µA |
| Standby power consumption PC | ≤ 26.4 mVA (UREF) |
| ≤ 26.4 mVA (UC) | |
| Reference test voltage UREF | 264V AC |
| Nominal discharge current In(8/20)µs | 5 kA |
| Maximum discharge current Imax(8/20) µs | 10 kA |
| Combined surge UOC | 6 kV |
| voltage protection level Up(L-N) | ≤ 1.25 kV (UOC) |
| ≤ 1.4 kV (In) | |
| voltage protection level Up(L-PE) | ≤ 1.4 kV |
| voltage protection level Up(N-PE) | ≤ 1.4 kV |
| UT(L-N) | 400V AC (5 seconds/withstand mode) |
| 457V AC (120 min/safe failure mode) | |
| UT(L-PE) | 457V AC (5 seconds/withstand mode) |
| 457V AC (120 min/tolerance mode) | |
| 1464V AC (200 ms/safety failure mode) | |
| UT(N-PE) | 1200V AC (200 ms/SAFE mode) |
| response time tA(L-N) | ≤ 25 ns |
| response time tA(L-PEN) | ≤ 100 ns |
| response time tA(N-PE) | ≤ 100 ns |
| Rated short-circuit current ISCCR | 10 kA AC |
| maximum spare fuse with branch wiring | 32 A (gG / B / C) |
| Additional technical data | |
| Rated short-circuit current ISCCR | 0.25 kA DC (no additional spare fuse in the DC branch) |
| 5 kA DC (for 20 A gG/B back-up protection fuses) | |
| Residual pressure Ures(L-N) | ≤ 1.15 kV (2 kA) |
| ≤ 1.25 kV (at 3 kA) | |
| ≤ 1.1 kV (UOC= 4 kV) | |
| Residual pressure Ures(L-PE) | ≤ 1.1 kV (2 kA) |
| ≤ 1.1 kV (at 3 kA) | |
| ≤ 1.2 kV (UOC= 4 kV) | |
| Residual pressure Ures(N-PE) | ≤ 1.1 kV (2 kA) |
| ≤ 1.1 kV (at 3 kA) | |
| ≤ 1.2 kV (UOC= 4 kV) | |