Phoenix PSR-SCP-42-230UC/URM4/4NO/2NC-expansion module 2702924,1-channel or 2-channel contact expansion, with wide range input, 4 normally open contacts, 1 normally closed contact, 1 confirmation current path, used with basic equipment, conforms to Class 4, PL e(EN ISO 13849 standard), plug-in screw connector, width: 22.5mm

Product Type safety relay
product series PSRclassic
Application Expansion Module
control Single and Dual Channel
mechanical life 10x 106Switch Times
Relay Model Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3
insulation characteristics
Overvoltage Level III
pollution level 2
Typical startup time (Us) < 100 ms (with Us/via A1 control)
Typical release time < 40 ms (A1 control at 42V DC)
< 200 ms (230V AC, via A1 control)
Recovery Time < 1 s

rated conditions 16.1W (IL² = 72 A², pTotal Maximum= 1.7W +14.4 W)
Rated operating mode 100% Eligible
Rated insulation voltage 250V AC
rated overvoltage/insulation
power supply
Rated control circuit supply voltage US 42V AC/DC -15 % / +10%
230V AC/DC -15 % / +10%
Rated control supply current IS Typical 35 mA (at 42V DC)
Typical 15 mA (230V AC)
US 1.5W (DC applicable)
1.7W (AC)
apparent power maximum 3.5 VA (US)
Impulse current < 20 A (& Delta;t = 100 μs, when Us)
protection circuit surge protection; suppression diodes and varistors

relays: enabling current paths
Output Description 2 normally open contacts in series, safety-related, floating
outputs 4
Contact Type 4 normally open safety contact outputs
Contact Material AgSnO2
Switching voltage Minimum 5V AC/DC
Max. 250V AC/DC
on-off capacity 50 mW minimum
Impulse current 10 mA minimum
max. 8 A
limit continuous current 6 A (pay attention to capacity reduction)
the square of the total current value 72 A2(pay attention to capacity reduction)
Switching frequency max. 0.5Hz
output fuse 6 A gL/gG (high demand)
4 A gL/gG (low requirement)
relays: diagnostic contacts (51/52)
Output Description 2 series normally open contacts, floating
outputs 1
Contact Type 1 feedback loop
Contact Material AgSnO2
Switching voltage Minimum 5V AC/DC
Max. 250V AC/DC
on-off capacity 50 mW minimum
Impulse current 10 mA minimum
max. 6 A
limit continuous current 1 A (see attenuation curve)
the square of the total current value 1 A2(see Attenuation curve)
Switching frequency max. 0.5Hz
output fuse 1 A (gL/gG)
Relays: Signal Transmission Current Path (61/62)
Output Description 2 parallel normally closed contacts, floating
outputs 1
Contact Material AgSnO2
Switching voltage Minimum 5V AC/DC
250V AC/DC
on-off capacity 50 mW minimum
Impulse current max. 6 A
limit continuous current 6 A (pay attention to capacity reduction)
the square of the total current value 36 A2(pay attention to capacity reduction)
Switching frequency max. 0.5Hz
2900509

Phoenix PSR-SCP-42-230UC/URM4/4NO/2NC-Extension Module 2702924