Phoenix PSR-SPP- 24UC/ESA4/2X1/1X2-safety relay 2963938, safety relay, used for emergency stop and safety door monitoring, safety level up to EN ISO 13849 standard SIL 3 or Cat. 4, PL e, dual channel operation, 2 active current paths, rated input voltage: 24V DC, plug-in connection
Product Type
safety relay
product series
PSRclassic
Application
Emergency stop button
safety door
control
dual channel
mechanical life
about 107 Switch Times
Relay Model
Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3
insulation characteristics
Overvoltage Level
III
pollution level
2
Electrical characteristics
rated conditions
16.44W (US = 26.4 V, IL ² = 72 A²,PTotal max = 2.04W +14.4 W)
Rated operating mode
100% Eligible
Rated insulation voltage
250V
rated overvoltage/insulation
see section "Insulation Coordination" in the data sheet.
input data
Overview
Rated control circuit supply voltage US
24V DC -15 % / +10%
US
Typical 1.68W (DC)
Rated control supply current IS
Typical 70 mA
to UN as reference
0.85 ... 1.1
UN
70 mA DC
Impulse current
< 3.5 A (Δt = 3 ms Us )
< 100 mA (Δt = 500 ms,Us /Ix )
> -100 mA (Δt = 300 ms,Us /Ix )
< 6 mA (Us /Ix to S34)
power consumption
Typical 38 mA (S12)
Typical -38 mA (S22)
typical 1 mA (Us /Ix to S34)
input/start and feedback circuit voltage
approx. 24V DC
filter time
5 ms (at A1, at the voltage dip Us )
Test pulse not allowed
Typical Response Time
150 ms (auto start)
Typical startup time (Us )
250 ms (when controlled by A1, there is us )
Typical Release Time
20 ms (via sensor loop as required)
45 ms (via A1 as required)
parallel
∞
Recovery Time
1 s (in accordance with the requirements of safety functions)
< 1 s (start-up time)
protection circuit
Surge protection; Suppressor diode
Allowable total conductor resistance
approx. 50 Ω (US )
Operating voltage display
Green LED
Status Display
LED (green)
Output Data
Contact Type
2 normally open safety contact outputs
1 signal transmission current path
Contact Material
AgSnO2 ,+ 0.2 µm Au
maximum switching voltage
250V AC/DC
Minimum Switching Voltage
10V AC/DC
limit continuous current
6 A (N/O contact)
Maximum impact current
6 A
Minimum impulse current
10 mA
the square of the total current value
72 A2 (normally open safety contact output)
36 A2 (signal current path 31/32)
Minimum on-off capacity
100 mW
output fuse
10 A gL/gG (normally open safety contact output)
4 A gL/gG (Low Demand Enable Current Path)
6 A gL/gG (signal transmission current path)
connection data
connection technology
pluggable
is
Wire Connection
Connection Mode
in-line connection
Rigid conductor cross section
0.2 mm² ... 1.5 mm²
Flexible Wire Cross Section
0.2 mm² ... 1.5 mm²
Flexible conductor cross-section, with sleeve, with plastic insulation sleeve
0.25 mm² ... 1.5 mm² (only with CRIMPFOX 6 wire clamps)
flexible conductor cross-section with cold press head without insulation sleeve
0.25 mm² ... 1.5 mm² (only with CRIMPFOX 6 wire clamps)
Wire Cross Section AWG
24 ... 16
stripping length
8mm