Phoenix PSR-SPP-230AC/ESAM2/3X1/1X2/B-safety relay 2901431, safety relay, used for emergency stop and safety door, safety level can reach SIL 1,Cat. 1,PL c, according to specific application, can meet SIL 3,Cat. 4,PL e safety level requirements, single channel operation, 3 enable current paths, rated input voltage of 230V AC, pluggable direct plug-in terminal

Product Type safety relay
Product Series PSRclassic
Application Emergency stop button
safety door
control single channel
mechanical life about 107Switch Times
Relay Model Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3
insulation characteristics
Overvoltage Level III
pollution level 2

rated conditions 2.88W
Rated operating mode 100% Eligible
Rated insulation voltage 250V AC
rated overvoltage/insulation 4 kV/basic insulation (safety isolation, reinforced insulation and 6 kV between A1-A2/logic/normally open safety contact output and display output)

Overview
Rated control circuit supply voltage US 230V AC -15 % / +10%
Rated control supply current IS 22 mA
input/start and feedback circuit voltage ~ 24V DC
Typical Response Time 50 ms (manual reset)
300 ms (auto start)
Typical startup time (Us) 300 ms (when controlled by a1 or S11/S12)
Typical release time 20 ms (when controlled by S11/S12)
150 ms (when controlled via A1)
Recovery Time 1 s
Maximum switching frequency 0.5Hz
protection circuit Surge protection; Suppressor diode
Surge protection; Varistor
Allowable total conductor resistance 50 Ω

Contact Type 3 normally open safety contact outputs
1 signal transmission current path
Contact Material AgSnO2, gold plated
maximum switching voltage 250V AC/DC
Minimum Switching Voltage 10V AC/DC
limit continuous current 6 A (normally open safety contact output)
5 A (signal transmission current path)
Maximum impact current 6 A
Minimum impulse current 10 mA
the square of the total current value 72 A2
Maximum power rating (resistive load) 144W (24V DC)
230W (available for 48V DC)
68W (available for 110V DC)
88W (available for 220V DC)
2000 VA (available for 250V AC)
Maximum power rating (inductive load) 48W (24V DC)
40W (available for 48V DC)
35W (available for 110V DC)
33W (available for 220V DC)
Minimum on-off capacity 100 mW
On-off capacity (360/h cycle) 6 A (24V DC)
5 A (230V AC)
on-off capacity (3600/h cycle) 3 A (24V (DC13))
3 A (230V (AC 15))
output fuse 10 A gL/gG NEOZED (normally open safety contact output)
6 A gL/gG NEOZED (auxiliary normally closed contact output)

connection technology
pluggable is
Wire Connection
Connection Mode in-line connection
Rigid conductor cross section 0.2 mm² ... 1.5 mm²
Flexible Wire Cross Section 0.2 mm² ... 1.5 mm²
Flexible conductor cross-section, with sleeve, with plastic insulation sleeve 0.25 mm² ... 1.5 mm² (only with CRIMPFOX 6 wire clamps)
flexible conductor cross-section with cold press head without insulation sleeve 0.25 mm² ... 1.5 mm² (only with CRIMPFOX 6 wire clamps)
Wire Cross Section AWG 24 ... 16
stripping length 8mm
2900509

Phoenix PSR-SPP-230AC/ESAM2/3X1/1X2/B-Safety relay 2901431

Product Center