Phoenix SUBCON-PLUS-CAN/PG-D-SUB bus connector 2708119,D-SUB connector, 9-position socket, 35 ° cable outlet, bus system: CAN, CANopen®, SafetyBUS p, maximum transmission speed of 1 Mbps, with PG D-SUB socket to connect Programming equipment, terminal resistance can be connected through sliding switch, pin assignment: 2, 3, 7, 9; screw terminal
| Product Type |
Data plug |
| MTTF |
6706 years (SN 29500 standard, temperature 25°C, duty cycle 21%) |
| 1817 years (SN 29500 standard, temperature 40°C, duty cycle 34.25%) |
| 155 years (SN 29500 standard, temperature 40°C, duty cycle 100%) |
| Pin Distribution |
2, 3, 7, 9 |
| Rated voltage UN |
5V |
| Rated current IN |
100 mA |
| transmission medium |
copper cable |
| D-SUB connection |
| Connection Mode |
D-SUB socket |
| PCB Connection |
| Connection Mode |
screw connection |
| stripping length |
5mm |
| Minimum cross section of rigid conductor |
0.14 mm² |
| Maximum cross section of rigid conductor |
1.5 mm² |
| flexible lead |
0.14 mm² |
| flexible conductor |
1 mm² |
| Single Wire/End Point, Minimum Rigid AWG |
26 |
| single wire/wiring point, maximum rigid AWG |
16 |
| AWG Wire Minimum Cross Section, Flexible |
26 |
| AWG stranded wire, flexible |
18 |
| programming connection |
| Connection Mode |
D-SUB connector |
| bus system |
CAN, CANopen, SafetyBus-P |
| signal |
CAN |
| CANopen® |
| SafetyBUS p |
| Dimensional drawing |
|
| width |
16.6mm |
| height |
39.4mm |
| length |
58mm |
| External dimensions |
| minimum outside diameter |
7.6mm |
| maximum outside diameter |
8.4mm |
| color (shell) |
Green (RAL 6021) |
| Identification Material (Shell) |
ABS (metal plating) |
| Cable outer diameter |
7.6mm... 8.4mm (bus line incoming) |
| Mechanical parameters |
| Insertion/unplugging cycle |
> 200 |
| meets EN 60068-2-6/IEC 60068-2-6 anti-vibration standards |
vibration (running): 5g,10 ... 150Hz, 2.5 h, XYZ direction |
| Conforms to EN 60068-2-27/IEC 60068-2-27 impact resistance standards |
impact force (operation): 15g,11 ms, half-sine shock pulse |
| environmental conditions |
| protection level |
IP40 |
| ambient temperature (operation) |
-20°C ... 75°C |
| ambient temperature (storage/transport) |
-25°C ... 80°C |
| elevation |
≤ 5000 m (see manufacturer's statement for high altitude operation for limits) |
| Allowable humidity (operating) |
10%... 95% (no condensation) |
| Allowable humidity (storage/transportation) |
5%... 95% (non-condensing) |