Phoenix VAL-SEC-T2-3C-440-FM-2 surge protector 2909968, plug-in surge protector, conforms to Class 2/Class II, used for 3-phase power network, zero-ground integration (4-wire system: L1, L2, L3, PEN), With remote communication contact.
Product Type
surge protector
product series
SEC Family
IEC Category
II
T2
EN Type
T2
IEC power supply system
TN-C
type
DIN rail module, split, detachable
Bits
3
Surge protection fault alarm
visual status indication window and remote alarm contact
insulation characteristics
Overvoltage Category
III
pollution level
2
Rated frequency fN
50Hz (60 Hz)
indicator/remote signaling
Connection Name
Remote alarm contact
switching function
changeover contact
Nominal operating voltage
5V AC ... 250V AC
125V DC (200 mA DC)
Operating current
5 mA AC ... 1 A AC
1 A DC (30V DC)
Connection Mode
screw connection
thread
M5
Tightening torque
4.5 Nm
stripping length
16mm
Flexible Wire Cross Section
2.5 mm² ... 16 mm²
Rigid conductor cross section
2.5 mm² ... 25 mm²
Attachable Guide Cross Section AWG
12 ... 4
Connection Mode
fork cable end
Flexible Wire Cross Section
1.5 mm² ... 6 mm²
Remote alarm contact
Connection Mode
COMBICON in-line/screw connection
thread
M2
Tightening torque
0.25 Nm
stripping length
7mm
Flexible Wire Cross Section
0.14 mm² ... 1.5 mm²
Rigid conductor cross section
0.14 mm² ... 1.5 mm²
Attachable Guide Cross Section AWG
28 ... 16
Dimensional drawing
width
37.3mm
height
97.9mm
depth
74.5mm (7.5mm with DIN rail)
Horizontal stitch pitch
Division 2
color (pin connector)
light gray (RAL 7035)
color (basic element)
gray (RAL 7042)
flame retardant rating to UL 94
V-0
material
600
insulation material
PA6.6-FR 20% GF
PBT-FR
Material Group
I
Shell Material
PA 6.6-FR 20 % GF
PBT-FR
protection channel
L-PEN
movement direction
3L-N/PE
Rated voltage UN
400/690V AC (TN-C)
400V AC (IT)
Rated frequency fN
50Hz (60 Hz)
Maximum continuous operating voltage UC
440V AC
Rated load current IL
40 A (Biconnect M4 fork cable pin 6 mm²)
63 A (TWIN cold press head 2 x 10 mm²)
Standby power consumption PC
≤ 540 mVA
Nominal discharge current In(8/20)µs
20 kA
Maximum discharge current Imax(8/20) µs
40 kA
Rated short-circuit current ISCCR
25 kA (for 315 A gG spare fuse)
50 kA (for 200 A gG spare fuse)
voltage protection level Up
≤ 1.9 kV
Residual pressure Ures
≤ 1.9 kV (In)
≤ 1.65 kV (10 kA)
≤ 1.5 kV (at 5 kA)
≤ 1.45 kV (at 4 kA)
≤ 1.35 kV (2 kA)
UT
581V AC (5 seconds/withstand mode)
762V AC (120 min/safe failure mode)
2905339
넳넲
Phoenix VAL-SEC-T2-3C-440-FM-2 class surge protector 2909968