Phoenix TMC 2 M 1 120 10,0A-thermal magnetic equipment circuit breaker 0915069, thermal magnetic circuit breaker, 2 positions, normal fuse, 1 normally open contact and 1 normally closed contact, universal feet can be installed on NS 32 or NS 35

Product Type Thermomagnetic Equipment Circuit Breaker
Product Series TMC
type rail mounting module, monolithic
Bits 2
connection quantity 4
Rows 2
Channels 1
insulation characteristics
Overvoltage Category II
pollution level 2

Fuse Type automatic equipment
Overview
Rated voltage 250V AC (3 AC 433 V)
65V DC
Nominal operating current IN 10 A
Rated overvoltage 2.5 kV
Insulation resistance Riso > 100 MΩ (500V DC)
auxiliary circuit 240V AC / 1 A (low inductance)
65V AC / 1 A (low inductance)
Breaking method TM (Thermomagnetic)
Device Impedance 0.02 Ω
Rated short-circuit switching capacity Icn 800 A
2500 A (32V DC)
Short-circuit switch capacity 5000 A ()
2000 A (UL 1077: 65V DC)
dielectric strength 3000V AC (operating area)
3000V AC (main circuit to auxiliary circuit)
1500V AC (bit in place)
Maximum switching times 10000 (1 x In, inductive)
Fuse M1 (normal fuse)
Contact Type 1 N/O contact
1 N/C contact
indicator/remote signaling
Connection Name auxiliary contact
Nominal operating voltage 240V AC
65V DC
Operating current 10 A AC (low inductance)

Main Contacts
Connection Mode screw connection
thread M3
Tightening torque 0.6 ... 0.8 Nm
stripping length 12mm
plug gauge A3
Rigid conductor cross section 0.2 mm² ... 6 mm²
cross-section AWG 24 ... 10 (as amended by IEC standards)
Flexible Wire Cross Section 0.2 mm² ... 4 mm²
Flexible conductor cross-section (sleeve without plastic insulation) 0.25 mm² ... 4 mm²
flexible conductor cross-section (sleeve with plastic insulating tube) 0.25 mm² ... 2.5 mm²
2 wires of the same cross section, rigid wire 0.2 mm² ... 0.75 mm²
2 wires with the same cross section, flexible wire 0.2 mm² ... 0.75 mm²
2 wires with the same cross section, flexible, with sleeve but not plastic sleeve 0.25 mm² ... 1 mm²
2 wires with the same cross section, flexible, with TWIN sleeve and plastic sleeve 0.5 mm² ... 2.5 mm²
Nominal current 10 A
Rated voltage 250V AC
65V DC
auxiliary contact
Connection Mode screw connection
thread M3
Tightening torque 0.6 ... 0.8 Nm
stripping length 12mm
plug gauge A1
Rigid conductor cross section 0.2 mm² ... 2.5 mm²
cross-section AWG 24 ... 14 (as amended by IEC standards)
Flexible Wire Cross Section 0.2 mm² ... 1.5 mm²
Flexible conductor cross-section (sleeve without plastic insulation) 0.25 mm² ... 2.5 mm²
flexible conductor cross-section (sleeve with plastic insulating tube) 0.25 mm² ... 1.5 mm²

Phoenix TMC 2 M 1 120 10,0A-Thermal Magnetic Equipment Circuit Breaker 0915069

Created on:2025-09-22 15:46

News Dynamics