Phoenix PI-EX Series: Explosion-Proof Industrial Modules - Selection Guide 

Product Overview

The Phoenix PI-EX Series consists of ATEX/IECEx-certified explosion-proof modules designed for safe operation in hazardous industrial environments (Zone 2/22). Covering functional categories including signal isolation, temperature acquisition, NAMUR sensor integration, digital I/O, power supply, and bus interface, these modules enable reliable signal processing, data transmission, and load control in explosive atmospheres. With robust industrial-grade construction, 35mm DIN rail mounting, and compliance with global 防爆 standards, they’re ideal for chemical plants, oil refineries, pharmaceutical facilities, and other scenarios requiring explosion-proof automation solutions.

Model Quick Reference Table

Model No. Product Name Function Type Core Features Application Scenarios
2835901 PI-EX-TB Explosion-Proof Terminal Block Basic terminal connection for hazardous areas Wiring distribution in Zone 2/22 environments
2865298 PI-EX-SD-24-48 Explosion-Proof Power Supply 24-48V DC output, explosion-proof design Power supply for low-voltage devices in hazardous areas
2835066 PI-EX-RTD-I RTD Temperature Input (Isolated) Isolated RTD (PT100/PT1000) input Isolated temperature monitoring in explosive zones
2865311 PI-EX-RTD RTD Temperature Input Non-isolated RTD input Basic RTD temperature acquisition in Zone 2/22
2865243 PI-EX-RPSS Signal Isolation/Repeater Signal amplification + isolation Signal enhancement for long-distance transmission in hazardous areas
2865117 PI-EX-NAM/TO-P NAMUR Sensor Interface (Plug-in) Plug-in NAMUR sensor compatibility Plug-and-play NAMUR sensor integration
2835574 PI-EX-NAM/TO NAMUR Sensor Interface Standard NAMUR (EN 60947-5-6) input NAMUR proximity switches/sensors in explosive environments
2835341 PI-EX-NAM/RNO-NE NAMUR Relay Output (NO, Non-Energized) NAMUR-controlled NO output (non-energized) NAMUR-triggered load control (normally open)
2835053 PI-EX-NAM/RNO NAMUR Relay Output (NO) NAMUR-controlled NO output Standard NAMUR NO load switching
2835367 PI-EX-NAM/RNC-NE NAMUR Relay Output (NC, Non-Energized) NAMUR-controlled NC output (non-energized) NAMUR-triggered load control (normally closed)
2835794 PI-EX-ME-RTD-I Mixed RTD Input (Isolated) Isolated multi-channel RTD input Multi-point isolated temperature monitoring
2835422 PI-EX-ME-RPSS-I/I Mixed Signal Isolator Dual-channel isolated signal conversion Dual-signal isolation/transmission in hazardous areas
2835435 PI-EX-ME-RPS-I/I Mixed Signal Repeater Dual-channel signal amplification Dual-signal enhancement for long distances
2835749 PI-EX-ME-ID-UI-I Mixed Digital-Analog Isolator Digital input → analog output (isolated) Digital-to-analog signal conversion in explosive zones
2835480 PI-EX-ME-2NAM/TO Dual NAMUR Sensor Interface 2-channel NAMUR input Multi-NAMUR sensor integration (e.g., dual proximity switches)
2865214 PI-EX-MB-S/16-01-2/D-SUB Bus Interface Module D-SUB connector, 16-channel signal interface Bus signal distribution via D-SUB in hazardous areas
2835985 PI-EX-MB-DI/16/FLK14/PLC/KD-S1 Digital Input Bus Module 16-channel DI, PLC-compatible Large-scale digital signal acquisition in Zone 2/22
2835613 PI-EX-IDS-I/I Isolated Digital Signal Converter Isolated digital signal conversion Noise-free digital signal processing in explosive environments
2835024 PI-EX-ID-I/I Isolated Digital Input Isolated dual-channel DI Isolated digital signal acquisition
2835325 PI-EX-ES-1/3 Safety Switch Interface 1-channel safety switch input Safety interlock integration in hazardous areas
2865120 PI-EX-DO/REL-S Explosion-Proof Relay Output Relay-based DO, explosion-proof Relay-controlled load switching in Zone 2/22
2865696 PI-EX-AIS Analog Input Sensor Interface Isolated analog sensor input Analog sensor (4-20mA/0-10V) integration in explosive zones

Core Technical Specifications (Universal)

Parameter Value Notes
Explosion Protection Certifications ATEX/IECEx (Zone 2/22, II 3G/D) Complies with global hazardous area standards
Supply Voltage 24-48V DC (20.4~52.8V) Wide voltage range for industrial use
Operating Temperature -25℃~70℃ Adapts to harsh hazardous environments
Mounting Type 35mm DIN rail (NS 35/7.5) Compact design, space-saving
Protection Class IP20 (cabinet mounting) Dust-proof, suitable for control cabinets in hazardous areas
Insulation Strength 2kV (input-output-supply) Anti-interference, ensures signal stability
Signal Compatibility NAMUR (EN 60947-5-6), RTD (PT100/PT1000), 4-20mA/0-10V Works with mainstream industrial sensors
Connection Type Screw/Push-in terminals Secure wiring for vibration-prone environments
Certifications CE, UL, CSA, ATEX, IECEx Global compliance for international deployment
Power Consumption ≤1.5W (single-channel); ≤3W (multi-channel) Low heat generation, safe in explosive atmospheres

Application Scenarios & Recommended Models

1. Temperature Monitoring in Hazardous Areas

  • Requirement: Isolated RTD input, multi-point acquisition
  • Recommended Models: 2835066 (PI-EX-RTD-I, isolated), 2835794 (PI-EX-ME-RTD-I, multi-channel)
  • Key Reason: RTD-specific design for PT100/PT1000 sensors; isolation prevents cross-interference in explosive zones

2. NAMUR Sensor Integration (Proximity Switches/Safety Sensors)

  • Requirement: NAMUR-compliant interface, single/dual-channel
  • Recommended Models: 2835574 (single-channel), 2835480 (dual-channel), 2865117 (plug-in)
  • Key Reason: Complies with EN 60947-5-6 for NAMUR sensors; plug-in/dual-channel options fit diverse integration needs

3. Digital/Analog Signal Isolation & Conversion

  • Requirement: Noise-free signal processing, long-distance transmission
  • Recommended Models: 2835613 (PI-EX-IDS-I/I, digital), 2835749 (PI-EX-ME-ID-UI-I, digital-analog), 2865696 (PI-EX-AIS, analog)
  • Key Reason: Isolation (2kV) eliminates electromagnetic interference; suitable for signal transmission in noisy hazardous environments

4. Large-Scale Digital Input Acquisition

  • Requirement: 16-channel DI, PLC compatibility
  • Recommended Model: 2835985 (PI-EX-MB-DI/16/FLK14/PLC/KD-S1)
  • Key Reason: High-channel density reduces cabinet space; direct PLC integration simplifies system design

5. Power Supply for Hazardous Area Devices

  • Requirement: Explosion-proof power delivery (24-48V DC)
  • Recommended Model: 2865298 (PI-EX-SD-24-48)
  • Key Reason: Explosion-proof design ensures safe power supply for low-voltage devices (sensors, modules) in Zone 2/22

6. Safety Interlock & Relay Control

  • Requirement: Safety switch interface, relay output
  • Recommended Models: 2835325 (PI-EX-ES-1/3, safety switch), 2865120 (PI-EX-DO/REL-S, relay output)
  • Key Reason: Safety-focused design for interlocks; relay output enables safe load switching in explosive atmospheres

Core Advantages

  • Global Explosion-Proof Compliance: ATEX/IECEx certifications (Zone 2/22) ensure safe operation in explosive atmospheres
  • Multifunctional Integration: Covers temperature acquisition, NAMUR integration, signal isolation, I/O, and power supply in one series
  • High Isolation Performance: 2kV insulation prevents signal interference and electrical hazards in harsh environments
  • Wide Sensor Compatibility: Works with NAMUR sensors, RTDs, analog/digital sensors, and safety switches
  • Rugged & Reliable: Wide operating temperature range (-25℃~70℃) and vibration-resistant design for hazardous area conditions
  • Easy System Integration: PLC-compatible, bus-ready, and standard mounting/wiring simplify deployment

Installation & Usage Notes

  • Explosion-Proof Compliance: Strictly follow ATEX/IECEx guidelines (e.g., correct zoning, grounding, cable gland selection)
  • Voltage Matching: Ensure supply voltage matches module ratings (24-48V DC); avoid overvoltage in unstable power grids
  • Wiring Specifications: Use explosion-proof cable glands and shielded cables; separate power and signal wiring to reduce interference
  • Module Spacing: Reserve ≥10mm between modules for heat dissipation (critical in enclosed hazardous area cabinets)
  • Sensor Compatibility: Verify sensors meet NAMUR/EN 60947-5-6 standards (for NAMUR modules) or RTD/analog specifications
  • Maintenance: Perform inspections in non-explosive atmospheres; avoid hot work near modules during operation
  • Certification Verification: Confirm module certifications match the site’s hazardous area classification (Zone 2/22)