Phoenix PLC-VT/TR/SC/RSC/RPT Series: Industrial Signal Conditioning, Relay & Interface Modules - Selection Guide 

Product Overview

The Phoenix PLC-XXX Series encompasses a diverse range of industrial modules, including visual terminals (VT)transmitters (TR)surge protection (SP)signal conversion (SC)relay signal conditioning (RSC), and repeaters/amplifiers (RPT). Designed for seamless integration with PLC systems, these modules support voltage ranges (12V DC~48V DC, 24V UC), functional variants (explosion-proof EX, sensor SEN, actuator ACT, high-current HC), and specialized signal processing (relay output, signal amplification, surge suppression). Featuring 35mm DIN rail mounting, robust industrial design, and global compliance, they’re ideal for manufacturing automation, process control, and hazardous area applications requiring reliable signal conditioning, relay control, and signal repetition.

Model Quick Reference Table

1. PLC-VT Series (Visual Terminals/Interface Modules)

Model No. Product Name Key Features Application Scenarios
2296854 PLC-VT/LA Visual terminal, LA logic function PLC interface with specialized logic visualization
2296870 PLC-VT Standard visual terminal Basic PLC human-machine interface (HMI) integration

2. PLC-TR Series (Transmission Modules)

Model No. Product Name Key Features Application Scenarios
2910141 PLC-TR-1T-MUL-300M-PT 1-channel, multi-range, 300m transmission, PT terminal Long-distance (300m) signal transmission (tool-free wiring)
2910140 PLC-TR-1T-MUL-300M 1-channel, multi-range, 300m transmission Standard long-distance signal transmission for PLC systems

3. PLC-SP/PLC-SC Series (Surge Protection & Signal Conversion)

Model No. Product Name Key Features Application Scenarios
2980555 PLC-SP-ELR W1/2-24DC Surge protection, ELR-compatible, 2-channel, 24V DC 24V DC ELR system surge suppression
2980539 PLC-SC-ELR W1/2-24DC Signal conversion, ELR-compatible, 2-channel, 24V DC 24V DC ELR system signal conditioning
2982663 PLC-SC-EIK 1-SVN 24P/P Signal conversion, EIK-compatible, 1-channel, 24V 24V DC EIK system signal conversion

4. PLC-RSC Series (Relay Signal Conditioning Modules)

4.1 24V DC/UC Input

Model No. Product Name Key Features Application Scenarios
2910536 PLC-RSC-24UC/2X21/FG 24V UC (AC/DC), 2×21 relay output, FG ground Universal voltage 2-channel relay signal conditioning
2967633 PLC-RSC-24UC/21HC 24V UC, 21HC high-current relay 24V universal voltage high-current load control
2910508 PLC-RSC-24UC/21-21AU/MS 24V UC, 21-21 dual relay + AU auxiliary + MS indicator Universal voltage dual-relay control with status feedback
2967112 PLC-RSC-24UC/21-21AU 24V UC, 21-21 dual relay + AU auxiliary Universal voltage dual-relay signal conditioning
2910503 PLC-RSC-24UC/21-21/MS 24V UC, 21-21 dual relay + MS indicator Universal voltage dual-relay control with mechanical status
2967073 PLC-RSC-24UC/21-21 24V UC, 21-21 dual relay Standard universal voltage dual-relay output
2909650 PLC-RSC-24UC/21/MS 24V UC, 21 relay + MS indicator Universal voltage single-relay control with status feedback
2966184 PLC-RSC-24UC/21 24V UC, 21 relay Standard universal voltage single-relay output
2982236 PLC-RSC-24UC/1/S/H 24V UC, 1-channel, S/H function Universal voltage single-channel signal conditioning
2307293 PLC-RSC-24DC/PMC T200/21HC 24V DC, PMC T200-compatible, 21HC high-current 24V DC high-current load control (PMC T200 system)

4.2 12V DC Input

Model No. Product Name Key Features Application Scenarios
2967617 PLC-RSC-12DC/21HC 12V DC, 21HC high-current relay 12V DC high-current load control
2967277 PLC-RSC-12DC/21-21AU 12V DC, 21-21 dual relay + AU auxiliary 12V DC dual-relay signal conditioning
2967235 PLC-RSC-12DC/21-21 12V DC, 21-21 dual relay Standard 12V DC dual-relay output
2966906 PLC-RSC-12DC/21 12V DC, 21 relay Standard 12V DC single-relay output
1078800 PLC-RSC-12DC/1IC/ACT 12V DC, 1IC input circuit, ACT actuator-dedicated 12V DC actuator signal conditioning

5. PLC-RPT Series (Repeater/Amplifier Modules)

Model No. Product Name Key Features Application Scenarios
2900301 PLC-RPT-48DC/21 48V DC, 21 relay output 48V DC signal repetition + relay control
2909528 PLC-RPT-24DC/21/EX 24V DC, 21 relay, EX explosion-proof Hazardous area (Zone 2) 24V DC signal repetition
2900299 PLC-RPT-24DC/21 24V DC, 21 relay output Standard 24V DC signal repetition + relay control
2900313 PLC-RPT-24DC/1AU/SEN 24V DC, 1AU auxiliary, SEN sensor-dedicated 24V DC sensor signal amplification + auxiliary output
2900312 PLC-RPT-24DC/1/ACT 24V DC, 1-channel, ACT actuator-dedicated 24V DC actuator signal amplification
2909513 PLC-RPT-12DC/21-21/EX 12V DC, 21-21 dual relay, EX explosion-proof Hazardous area dual-channel 12V DC signal repetition

Core Technical Specifications (Universal)

Parameter Value Notes
Supply Voltage 12V DC (10.8~13.2V), 24V DC (19.2~28.8V), 24V UC (18~30V AC/DC), 48V DC (43.2~52.8V) Model-dependent voltage compatibility
Output Type Relay (NO/NC), auxiliary voltage output PLC-RSC/RPT: Relay contact rating up to 10A (HC models)
Functional Features Surge protection, signal amplification, relay control, explosion-proof (EX) Sub-series dependent
Transmission Distance Up to 300m (PLC-TR series) Long-distance signal transmission
Operating Temperature Standard: -25℃~70℃; EX models: -20℃~60℃ Industrial-grade temperature tolerance
Mounting Type 35mm DIN rail (NS 35/7.5) Compact design for space-saving cabinet layout
Protection Class IP20 (cabinet mounting); EX models: IP20 + ATEX/IECEx Dust-proof; EX for Zone 2 hazardous areas
Certifications CE, UL, CSA; EX models: ATEX/IECEx (Zone 2) Global industrial and hazardous area compliance
Terminal Types PT (plug-in, tool-free): 0.14~2.5mm²; Screw: 0.14~2.5mm² PLC-TR: PT terminal option for fast maintenance
Isolation Voltage 2kV (input-output) Anti-interference for stable signal processing

Application Scenarios & Recommended Models

1. Hazardous Area 24V DC Signal Repetition (Relay Output)

  • Requirement: Explosion-proof signal repeater with relay output for Zone 2 environments
  • Recommended Model: 2909528 (PLC-RPT-24DC/21/EX)
  • Key Reason: EX certification (Zone 2); 21 relay output; 24V DC compatibility with industrial sensors

2. Long-Distance (300m) Signal Transmission (Tool-Free Wiring)

  • Requirement: Multi-range signal transmission for PLC systems with quick maintenance
  • Recommended Model: 2910141 (PLC-TR-1T-MUL-300M-PT)
  • Key Reason: 300m transmission distance; PT plug-in terminal; multi-range voltage compatibility

3. 24V Universal Voltage High-Current Load Control

  • Requirement: 24V AC/DC (UC) high-current relay control for heavy-duty equipment
  • Recommended Model: 2967633 (PLC-RSC-24UC/21HC)
  • Key Reason: 24V UC universal input; 21HC high-current relay (up to 10A); signal conditioning function

4. 12V DC Actuator Signal Conditioning

  • Requirement: 12V DC actuator-specific signal conditioning with input circuit protection
  • Recommended Model: 1078800 (PLC-RSC-12DC/1IC/ACT)
  • Key Reason: ACT actuator-dedicated design; 1IC input circuit protection; 12V DC compatibility

5. Sensor Signal Amplification (24V DC, Auxiliary Output)

  • Requirement: 24V DC sensor signal repetition with auxiliary output for PLC feedback
  • Recommended Model: 2900313 (PLC-RPT-24DC/1AU/SEN)
  • Key Reason: SEN sensor-dedicated interface; 1AU auxiliary output; signal amplification for weak sensor signals

Core Advantages

  • Diverse Functional Coverage: Visual terminals, transmitters, surge protection, relay conditioning, and repeaters in one product family
  • Wide Voltage Compatibility: 12V DC~48V DC, 24V UC (AC/DC) supports global industrial power systems
  • Hazardous Area Compliance: EX-suffix models enable Zone 2 deployment for critical applications
  • Sensor/Actuator Specialization: SEN/ACT suffixes ensure seamless integration with industrial devices
  • High-Current Support: HC models handle up to 10A load current for heavy-duty control
  • Long-Distance Transmission: PLC-TR series supports up to 300m signal transmission
  • Flexible Terminal Options: PT plug-in terminals for fast maintenance; screw terminals for secure wiring
  • Industrial-Grade Reliability: -25℃~70℃ operating range, 2kV isolation, and IP20 protection

Installation & Usage Notes

  • Voltage Matching: Ensure supply voltage aligns with module ratings (e.g., 12DC/24DC/24UC/48DC)
  • EX Model Deployment: Install EX-suffixed models per ATEX/IECEx guidelines (proper grounding, Zone 2 restriction)
  • Relay Load Capacity: Do not exceed relay contact rating (standard: 5A; HC models: 10A)
  • Transmission Wiring: For PLC-TR (300m), use shielded twisted-pair cables to minimize signal attenuation
  • Terminal Selection: Use PT plug-in terminals for frequent maintenance; screw terminals for vibration-prone environments
  • Sensor/Actuator Compatibility: Select SEN-suffix models for sensors and ACT-suffix for actuators to ensure signal matching
  • Mounting Spacing: Reserve ≥3mm between modules for heat dissipation, especially for HC high-current variants
  • Environmental Protection: Install in dry, dust-free control cabinets (IP20 protection); avoid moisture/corrosive substances
  • Status Monitoring: For MS-suffix models, verify mechanical status indicators post-installation to confirm proper operation

Phoenix PLC-VT/TR/SC/RSC/RPT Series: Industrial Signal Conditioning, Relay & Interface Modules - Selection Guide