In the stable operation of industrial automation and power systems, surge protection is an indispensable key link. As a world-renowned supplier of industrial electronic components, Phoenix's FLT series surge protectors have become the preferred solution for numerous industrial scenarios with their excellent protection performance and stable product quality. This article compiles the product codes, specifications and product descriptions of various popular models of the FLT series, helping procurement, technical and operation and maintenance personnel quickly complete model selection and matching.

1. FLT Series Surge Protector Core Model List (Including Product Descriptions)

For easy reference, the following is a table of product codes, models and product descriptions of different specifications of the FLT series, covering the protection needs of various voltage levels and wiring methods:

Product Code Product Model Product Description
2816894 FLT35 CTRL-1.5 Single-phase control-type surge protector with a discharge current capacity of 35kA and a protection level of 1.5kV. It responds accurately to overvoltage in control circuits and is suitable for voltage-sensitive control scenarios.
2856388 FLT100N/PE CTRL-1.5 Designed with N-PE wiring and control-type structure, it has a discharge current capacity of 100kA and a protection level of 1.5kV, providing targeted protection against surge impacts between the neutral line and protective earth.
2800107 FLT 60-400 Single-phase general-purpose surge protector with a discharge current capacity of 60kA and a maximum continuous operating voltage of 400V, suitable for basic protection of low-voltage distribution circuits.
2800109 FLT 50 N/PE CTRL-2.0 N-PE wiring control-type product with a discharge current capacity of 50kA and a protection level of 2.0kV. It has precise voltage response characteristics and is suitable for neutral line protection of key equipment.
2817453 FLT 50 N/PE CTRL-1.5 N-PE wiring control-type surge protector with a discharge current capacity of 50kA and a protection level of 1.5kV. It responds quickly and can effectively suppress transient overvoltage between the neutral line and earth.
2800108 FLT 50 N/PE Basic N-PE surge protector with a discharge current capacity of 50kA. It features a simple and reliable structure, suitable for surge protection of neutral lines and protective earth in conventional scenarios.
2816904 FLT 50 N/PE Same specifications as model 2800108, with N-PE wiring and a discharge current capacity of 50kA. It provides stable surge protection for neutral lines and earth, compatible with various industrial environments.
2838940 FLT 35-260 Single-phase Type 1 surge protector with a discharge current capacity of 35kA and a maximum continuous operating voltage of 260V, ideal for the first-level lightning protection of single-phase power supply systems.
2856317 FLT 35/3+1 CTRL-0.9/I Three-phase + neutral line control-type surge protector with a discharge current capacity of 35kA and a protection level of 0.9kV. Equipped with an optical fault indicator, it provides real-time feedback on working status and is suitable for three-phase control circuits.
2800131 FLT 35/3+1 Three-phase + neutral line wiring design with a discharge current capacity of 35kA, covering full-loop protection of three-phase power distribution systems, applicable to scenarios such as the front end of building main distribution boxes.
2817482 FLT 35/3+1 Same parameters as model 2800131, with three-phase + neutral line configuration and a discharge current capacity of 35kA, providing comprehensive surge protection for three-phase power supply systems.
2856304 FLT 35/3 CTRL-0.9/I Three-phase control-type surge protector with a discharge current capacity of 35kA and a protection level of 0.9kV. With a fault indicator, it accurately protects three-phase control circuits from overvoltage.
2800129 FLT 35/3 Three-phase general-purpose product with a discharge current capacity of 35kA, compatible with three-phase power distribution systems. Easy to install, it is suitable for surge protection of industrial workshop distribution circuits.
2816881 FLT 35/3 Same specifications as model 2800129, with three-phase wiring and a discharge current capacity of 35kA, providing stable surge protection for three-phase equipment with high reliability.
2801635 FLT 35 CTRL-4.0 Single-phase control-type surge protector with a discharge current capacity of 35kA and a protection level of 4.0kV, with a maximum continuous operating voltage of 260V, suitable for control circuits with specific protection threshold requirements.
2800115 FLT 35 CTRL-2.0/I Single-phase control-type surge protector with a discharge current capacity of 35kA and a protection level of 2.0kV. Equipped with an optical fault indicator and fast response time, it is suitable for protection of sensitive control circuits.
2817437 FLT 35 CTRL-1.5/I Single-phase Type 1+2 combined protector with a protection level of 1.5kV and a response time ≤ 100ns. With an indicator light, it is suitable for scenarios requiring high response speed.
2817424 FLT 35 CTRL-0.9/I Single-phase control-type surge protector with a protection level of 0.9kV and a discharge current capacity of 35kA. With fault indication function, it accurately protects low-voltage control circuits from surges.
2800030 FLT 35 CTRL-0.9/50 Single-phase control-type surge protector with a protection level of 0.9kV and a discharge current capacity of 35kA, suitable for 50A circuit scenarios, providing customized protection for specific current-level circuits.
2817411 FLT 35 CTRL-0.9 Single-phase control-type surge protector with a protection level of 0.9kV and a discharge current capacity of 35kA. It responds accurately and is suitable for voltage-sensitive control circuits.
2800106 FLT 25-400 Single-phase general-purpose surge protector with a discharge current capacity of 25kA and a maximum continuous operating voltage of 400V, suitable for secondary surge protection of low-voltage power distribution systems.
2809717 FLT 25-400 Same specifications as model 2800106, with a discharge current capacity of 25kA and an operating voltage of 400V, providing basic surge protection for low-voltage equipment with high cost performance.
2801299 FLT 25-3S-350 Three-phase Type 1 protector with a discharge current capacity of 25kA and a maximum continuous operating voltage of 350V, suitable for primary lightning protection of three-phase power grids.
2801300 FLT 25-3C-350 Three-phase general-purpose surge protector with a discharge current capacity of 25kA and an operating voltage of 350V. Compact in structure, it is suitable for three-phase power distribution scenarios with limited space.
2801204 FLT 25-1S-350 Single-phase Type 1 surge protector with a discharge current capacity of 25kA and an operating voltage of 350V, suitable for primary lightning protection of single-phase power supply systems.
2838160 FLT 100-260 Single-phase Type 1+2 combined protector with a discharge current capacity of 100kA, a response time ≤ 100ns and an operating voltage of 260V, suitable for enhanced protection in high surge risk scenarios.
2800303 FLT 100 N/PE-1.5 N-PE wiring design with a discharge current capacity of 100kA and a protection level of 1.5kV, providing high-strength surge protection for neutral lines and earth.
2905834 FLT 100 N/PE CTRL-3.0 N-PE wiring control-type surge protector with a discharge current capacity of 100kA and a protection level of 3.0kV, accurately responding to surge impacts between the neutral line and earth.
2800029 FLT 100 N/PE CTRL-1.5/25 N-PE wiring control-type surge protector with a protection level of 1.5kV and a discharge current capacity of 100kA, suitable for 25A circuits, providing precise protection for specific current scenarios.

2. Quick Interpretation of Model Specifications

The suffix parameters of the FLT series models contain key product information. Mastering the following rules can quickly determine the applicable scenarios of the product:

  1. Series Identification: Such as FLT 25/35/50/60/100, representing different rated voltages and protection levels, suitable for different scenarios such as low-voltage power distribution and industrial control.
  2. Wiring Method: /3 represents three-phase wiring, /3+1 represents three-phase plus neutral line wiring, and N/PE refers to surge protection between the neutral line and protective earth.
  3. Control Type: Models with the "CTRL" suffix are control-type surge protectors, which have precise voltage response characteristics and are suitable for control circuits requiring high sensitivity.
  4. Parameter Suffix: Such as CTRL-1.5, -0.9/I, etc., representing core technical parameters of the product such as maximum continuous operating voltage and response time, which need to be matched according to on-site working conditions.
  5. Function Identification: Models with the "I" suffix are equipped with an optical fault indicator, which can provide real-time feedback on product working status and facilitate operation and maintenance troubleshooting.

3. Working Principle of Surge Protectors

The core function of a surge protector is to limit transient overvoltage and safely discharge surge current to the ground, thereby protecting subsequent electrical equipment from surge impacts caused by lightning, power grid fluctuations and other factors. The working process of the FLT series surge protectors can be divided into three stages:

  1. High-Impedance State Under Normal Working ConditionsWhen the power grid voltage is within the rated range, the core components inside the surge protector (such as varistors and discharge gaps) are in a high-impedance state, with almost no current conduction, only weak leakage current exists, which will not affect the normal power supply of the system.
  2. Rapid Conduction When Surge OccursWhen transient overvoltage occurs in the power grid caused by lightning induction, switch operation and other factors, and the voltage value exceeds the starting voltage of the surge protector, the internal core components will quickly switch from a high-impedance state to a low-impedance state within nanoseconds, forming a temporary current discharge channel. At this time, the surge current will be quickly guided to the ground through the surge protector, avoiding the current flowing into the subsequent precision equipment.For control-type models with the "CTRL" suffix, their starting voltage accuracy is higher, which can respond immediately when the overvoltage just reaches the threshold, suitable for control circuits sensitive to voltage fluctuations.
  3. Automatic Reset After Surge SubsidesWhen the transient overvoltage disappears and the power grid voltage returns to the rated range, the internal core components will automatically return to the high-impedance state, and the surge protector will return to the standby state, waiting for the next surge impact. The FLT series products have stable reset performance, can withstand multiple surge impacts repeatedly, and do not need frequent replacement.

4. Core Advantages of FLT Series Products

  1. High Reliability: Phoenix's FLT series products have passed rigorous industrial environment tests and can operate stably under complex working conditions such as high temperature, high humidity and strong electromagnetic interference.
  2. Comprehensive Protection: Covering the full range of wiring needs from single-phase to three-phase, it can effectively suppress voltage impacts caused by lightning surges, power grid fluctuations, etc., and protect subsequent precision equipment.
  3. Easy Installation and Maintenance: The products adopt a standardized design, compatible with Phoenix's terminal blocks and mounting rails, enabling quick plug-in and replacement, and reducing operation and maintenance costs.
  4. Precise Response: Control-type models (with the CTRL suffix) have a more accurate starting voltage threshold, which can specifically protect control circuits sensitive to voltage fluctuations and avoid false triggering or response lag.
  5. Visible Status: Models with the "I" suffix are equipped with an optical fault indicator, providing real-time feedback on working status, facilitating operation and maintenance personnel to detect faults and replace them in a timely manner.

5. Selection Suggestions

  1. Prioritize selecting the corresponding series (such as 25/35/100 series) according to the on-site voltage level, and then determine the specific model according to the wiring method.
  2. For control circuits, it is recommended to select models with the "CTRL" suffix; for power distribution circuits, conventional models can be selected according to the surge level.
  3. For key equipment or scenarios with high operation and maintenance difficulty, priority should be given to models with a fault indicator (I suffix) to facilitate status monitoring.
  4. If there are special working conditions (such as high altitude, strong corrosion environment), it is recommended to refer to the product technical manual or consult professional engineers for model selection.

If you encounter any problems in the selection or application of FLT series products, please feel free to consult us, and we will provide you with professional technical support and solutions.