In industrial circuit wiring, signal distribution, status monitoring and high-voltage circuit connection scenarios, Phoenix UT series terminal components are highly trusted for their diversified specification configuration, rich functional extensions and reliable industrial-grade performance. This guide collates the product codes, models and detailed descriptions of UT 6 and UT 4 series, helping electrical design, procurement and maintenance personnel quickly select suitable products for different industrial wiring requirements.

1. UT Series Core Model List (With Product Descriptions)

Product Code Product Model Product Description
UT 6 Series (High-load Terminal)    
3070121 UT 6-T-HV P/P UT 6-spec high-voltage (HV) terminal, T-type structure with P/P dual polarity identification, suitable for high-voltage industrial circuit connection with polarity requirements
3070134 UT 6-T-HV UT 6-spec high-voltage terminal, T-type basic structure, designed for general high-voltage 6-spec circuit wiring scenarios
3044157 UT 6-PE UT 6-spec terminal with PE protection grounding function, enhancing electrical safety in high-load industrial circuit connection
3046427 UT 6-HESILED 60 (6,3X32) UT 6-spec terminal equipped with 60-type HESI LED indicator (6.3×32mm size), providing clear working status feedback, suitable for key 6-spec circuit monitoring
3046414 UT 6-HESILED 24 (6,3X32) UT 6-spec terminal with 24V HESI LED indicator (6.3×32mm size), low power consumption, ideal for DC 24V 6-spec circuit status monitoring
3046430 UT 6-HESILA 250 (6,3X32) UT 6-spec terminal with 250-type HESI indicator (6.3×32mm size), suitable for high-voltage 6-spec circuit status detection
3046401 UT 6-HESI (6,3X32) UT 6-spec terminal with HESI basic status monitoring module (6.3×32mm size), supporting customized status feedback for complex 6-spec systems
3046703 UT 6-3L UT 6-spec terminal with 3L three-phase identification design, facilitating correct wiring of three-phase AC 6-spec circuits
3044144 UT 6 BU UT 6-spec terminal with blue (BU) appearance, easy to distinguish in dense wiring environments, suitable for 6-spec signal circuit distribution
3044131 UT 6 UT 6-spec basic terminal component, high current-carrying capacity, cost-effective choice for general high-load 6-spec industrial circuit connection
UT 4 Series (Medium-load Terminal)    
Multi-channel Configuration Models    
3044364 UT 4-TWIN UT 4-spec TWIN dual-channel terminal, suitable for parallel connection of two groups of 4-spec circuits in compact installation spaces
3046168 UT 4-TG-P/P UT 4-spec TG-type terminal with P/P dual polarity identification, ideal for dual-polarity 4-spec circuit connection scenarios
3046142 UT 4-TG UT 4-spec TG-type basic terminal, suitable for general 4-spec circuit control and signal transmission
3064027 UT 4-QUATTRO-TG UT 4-spec QUATTRO four-channel TG-type terminal, designed for large-scale 4-spec circuit distribution in industrial control systems
3064056 UT 4-QUATTRO-MT P/P UT 4-spec QUATTRO four-channel MT-type terminal with P/P dual polarity identification, suitable for multi-channel dual-polarity 4-spec circuit connection
3060335 UT 4-QUATTRO/ 2P-F UT 4-spec QUATTRO terminal with 2P dual-circuit + F enhanced function, improving control precision of multi-channel 4-spec systems
3060306 UT 4-QUATTRO/ 2P BU UT 4-spec QUATTRO terminal with 2P dual-circuit configuration and blue (BU) appearance, facilitating quick identification of 2P circuit groups
3060296 UT 4-QUATTRO/ 2P UT 4-spec QUATTRO terminal with 2P dual-circuit configuration, suitable for parallel connection of two groups of four-channel 4-spec circuits
3044584 UT 4-QUATTRO BU UT 4-spec QUATTRO four-channel terminal with blue (BU) appearance, ideal for multi-channel 4-spec signal circuit distribution with visual identification needs
3044571 UT 4-QUATTRO UT 4-spec QUATTRO four-channel basic terminal, compact structure, suitable for general multi-channel 4-spec industrial circuit connection
Status Monitoring Models    
3214321 UT 4-PE/L/HESILED 24 (5X20) 120KOHM UT 4-spec terminal with PE grounding + L-phase identification + 24V HESI LED indicator (5×20mm size), 120KΩ matching resistance, suitable for high-precision 4-spec circuit safety monitoring
3214366 UT 4-L/HESILED 24 (5X20) 120KOHM UT 4-spec terminal with L-phase identification + 24V HESI LED indicator (5×20mm size), 120KΩ resistance, designed for 4-spec circuit phase and status monitoring
3214368 UT 4-L/HESILA 250 (5X20) UT 4-spec terminal with L-phase identification + 250-type HESI indicator (5×20mm size), suitable for high-voltage 4-spec circuit phase monitoring
1044423 UT 4-L/HESI (5X20) GY UT 4-spec terminal with L-phase identification + HESI module (5×20mm size), gray (GY) appearance, ideal for 4-spec circuit phase and status detection
3214325 UT 4-L/HESI (5X20) UT 4-spec terminal with L-phase identification + HESI basic module (5×20mm size), suitable for general 4-spec circuit phase monitoring
3046126 UT 4-HESILED 60 (5X20) UT 4-spec terminal with 60-type HESI LED indicator (5×20mm size), suitable for key 4-spec circuit status monitoring
1021497 UT 4-HESILED 24 (5X20)-EX UT 4-spec terminal with 24V HESI LED indicator (5×20mm size), explosion-proof (EX) grade, designed for hazardous environment 4-spec circuit monitoring
3074172 UT 4-HESILED 24 (5X20) GY UT 4-spec terminal with 24V HESI LED indicator (5×20mm size), gray (GY) appearance, suitable for 4-spec circuit status monitoring with visual identification needs
3046537 UT 4-HESILED 24 (5X20) BU UT 4-spec terminal with 24V HESI LED indicator (5×20mm size), blue (BU) appearance, ideal for 4-spec signal circuit status monitoring
3046090 UT 4-HESILED 24 (5X20) UT 4-spec terminal with 24V HESI LED indicator (5×20mm size), cost-effective choice for general 4-spec circuit status monitoring
1021495 UT 4-HESILA 250 (5X20)-EX UT 4-spec terminal with 250-type HESI indicator (5×20mm size), explosion-proof (EX) performance, suitable for hazardous environment high-voltage 4-spec circuit monitoring
3046100 UT 4-HESILA 250 (5X20) UT 4-spec terminal with 250-type HESI indicator (5×20mm size), suitable for general high-voltage 4-spec circuit status detection
1021498 UT 4-HESI (5X20)-EX UT 4-spec terminal with HESI basic module (5×20mm size), explosion-proof (EX) grade, designed for hazardous environment 4-spec circuit status feedback
3074169 UT 4-HESI (5X20) GY UT 4-spec terminal with HESI basic module (5×20mm size), gray (GY) appearance, suitable for general 4-spec circuit status monitoring
3046032 UT 4-HESI (5X20) UT 4-spec terminal with HESI basic status monitoring module (5×20mm size), compatible with most 4-spec industrial control systems
Special Function Models    
3044128 UT 4-PE UT 4-spec terminal with PE protection grounding function, enhancing electrical safety in medium-load 4-spec industrial circuit connection
3046171 UT 4-MT-P/P UT 4-spec MT-type terminal with P/P dual polarity identification, suitable for multi-terminal dual-polarity 4-spec circuit connection
3046236 UT 4-MTD-DIO/R-L UT 4-spec MTD-type terminal with DIO digital interface and R-L signal direction identification, ideal for industrial automation 4-spec signal transmission
3046346 UT 4-MTD-DIO/L-R-P/P UT 4-spec MTD-type terminal with DIO digital interface, L-R signal direction and P/P polarity identification, suitable for high-precision 4-spec digital control scenarios
3046210 UT 4-MTD-DIO/L-R UT 4-spec MTD-type terminal with DIO digital interface and L-R signal direction identification, suitable for general 4-spec digital circuit connection
3046184 UT 4-MTD UT 4-spec MTD-type basic terminal, compact structure, suitable for space-limited 4-spec circuit control
3046139 UT 4-MT UT 4-spec MT-type multi-terminal terminal, supporting parallel connection of multiple 4-spec circuits, ideal for dense wiring environments
3046252 UT 4-HEDI-P/P UT 4-spec terminal with HEDI high-precision detection function and P/P polarity identification, suitable for 4-spec circuit precision control scenarios
3046249 UT 4-HEDI UT 4-spec terminal with HEDI basic detection function, designed for 4-spec circuit signal detection and feedback
3045606 UT 4/ 1P-PE UT 4-spec 1P single-circuit terminal with PE grounding function, suitable for single-circuit 4-spec signal circuit connection with safety requirements
3045583 UT 4/ 1P UT 4-spec 1P single-circuit basic terminal, cost-effective choice for general single-circuit 4-spec circuit connection
Basic Models    
3045101 UT 4 OG UT 4-spec terminal with orange (OG) appearance, facilitating quick identification of main circuits in complex wiring systems
3044115 UT 4 BU UT 4-spec terminal with blue (BU) appearance, suitable for 4-spec signal circuit distribution with visual identification needs
3044102 UT 4 UT 4-spec basic terminal component, balanced current-carrying capacity and installation space, suitable for general medium-load 4-spec industrial circuit connection

2. Quick Interpretation of UT Series Model Naming Rules

Mastering the naming logic can help you quickly identify the core parameters and applicable scenarios of the product:

  1. Series Prefix & Spec
    • UT: Phoenix dedicated industrial terminal series, focusing on circuit connection, signal distribution and status monitoring.
    • 6/4: Core current-carrying specification of the terminal. UT 6 is for high-load industrial circuits; UT 4 is for medium-load control and signal circuits.
  2. Function Suffix Mark
    • HV: High-voltage adaptation, suitable for high-voltage industrial circuit connection scenarios.
    • PE: Protection grounding function, enhancing the electrical safety of the circuit.
    • HESILED/HESILA/HESI: Status monitoring function series. HESILED is LED indicator (with voltage specification), HESILA is high-voltage indicator, HESI is basic monitoring module; the following (XX×XX) is the indicator size.
    • EX: Explosion-proof grade, suitable for hazardous industrial environments with flammable and explosive risks.
    • TWIN/QUATTRO: Multi-channel configuration. TWIN is dual-channel, QUATTRO is four-channel, adapting to multi-circuit parallel connection needs.
    • TG/MT/MTD: Terminal structure type, TG is general type, MT is multi-terminal type, MTD is digital interface integrated type.
    • DIO: Digital input/output interface, with signal direction identification (R-L/L-R), suitable for industrial automation system connection.
    • 3L/L: Phase identification function, 3L is three-phase, L is single-phase, ensuring correct AC circuit wiring.
    • F/HEDI: Enhanced function, F improves control precision, HEDI realizes high-precision signal detection.
    • P/P: Dual polarity identification, suitable for dual-polarity circuit connection scenarios.
  3. Appearance & Size Parameter
    • BU/OG/GY: Color coding, blue/orange/gray appearance facilitates quick circuit identification in complex wiring environments.
    • (6,3X32)/(5X20): Size of the status indicator module in millimeters, determining the installation compatibility with the terminal.
    • 120KOHM: Matching resistance parameter, tailored for high-precision circuit monitoring scenarios.

3. Core Advantages of Phoenix UT Series Terminals

  1. Diversified Spec & Channel ConfigurationCovers UT 6 high-load and UT 4 medium-load two core specs, plus TWIN dual-channel and QUATTRO four-channel multi-channel configurations, meeting the connection needs of high-power main circuits, medium-load control circuits and multi-channel signal systems in industrial systems.
  2. Rich Extended Function SupportIntegrates protection grounding, status monitoring (with explosion-proof option), phase identification, digital interface and polarity identification functions, adapting to complex industrial application scenarios such as hazardous environment monitoring, digital control and three-phase wiring.
  3. Clear Visual Identification DesignProvides multiple color coding options (BU/OG/GY) and phase identification marks, facilitating quick circuit distinction and maintenance in dense wiring environments, reducing wiring errors and maintenance time.
  4. Strong Compatibility & Easy InstallationAdopts standard industrial mounting dimensions, compatible with Phoenix's mounting rails and accessories, realizing quick plug-in and replacement, suitable for dense wiring environments in control cabinets.
  5. Industrial-grade Reliable PerformancePasses strict high-temperature, high-humidity and vibration resistance tests, with stable operation in harsh industrial environments; explosion-proof models comply with hazardous environment safety standards, ensuring long-term reliable work of the circuit connection system.

4. Product Selection Suggestions

  1. Spec Matching According to Current Load
    • For high-power industrial main circuits (such as motor power supply): Select UT 6 series models.
    • For medium-load control and signal circuits (such as sensor connection): Choose UT 4 series models.
  2. Channel Configuration Selection Based on Circuit Quantity
    • For multi-circuit parallel connection: Select TWIN dual-channel models for small-scale parallel; choose QUATTRO four-channel models for large-scale distribution.
    • For single-circuit or simple dual-circuit connection: Adopt basic UT 6/UT 4 models to reduce costs.
  3. Function Selection Based on Scenario Requirements
    • For hazardous environment circuit monitoring: Prioritize models with EX explosion-proof suffix + HESILED/HESI status monitoring function.
    • For circuit safety requirements: Select models with PE protection grounding suffix.
    • For industrial automation digital control: Choose models with DIO digital interface suffix, and match the signal direction (R-L/L-R) according to the system requirements.
    • For three-phase AC circuit wiring: Select UT 6-3L model with three-phase identification function.
    • For dual-polarity circuit connection: Adopt models with P/P polarity identification suffix.
  4. Identification & Cost Optimization
    • For complex wiring systems: Select color-coded models (BU/OG/GY) to improve maintenance efficiency.
    • For general non-critical circuits: Choose basic structure models without additional function suffixes (such as UT 6, UT 4) to reduce procurement costs.

Phoenix UT Series Terminal Components Product Selection Guide

Created on:2026-01-09 10:02

News Dynamics

NEWS