Phoenix UT Series Terminal Components Product Selection Guide
In industrial circuit wiring, signal distribution, status monitoring and high-voltage circuit connection scenarios, Phoenix UT series terminal components are highly trusted for their diversified specification configuration, rich functional extensions and reliable industrial-grade performance. This guide collates the product codes, models and detailed descriptions of UT 6 and UT 4 series, helping electrical design, procurement and maintenance personnel quickly select suitable products for different industrial wiring requirements.
1. UT Series Core Model List (With Product Descriptions)
| Product Code | Product Model | Product Description |
|---|---|---|
| UT 6 Series (High-load Terminal) | ||
| 3070121 | UT 6-T-HV P/P | UT 6-spec high-voltage (HV) terminal, T-type structure with P/P dual polarity identification, suitable for high-voltage industrial circuit connection with polarity requirements |
| 3070134 | UT 6-T-HV | UT 6-spec high-voltage terminal, T-type basic structure, designed for general high-voltage 6-spec circuit wiring scenarios |
| 3044157 | UT 6-PE | UT 6-spec terminal with PE protection grounding function, enhancing electrical safety in high-load industrial circuit connection |
| 3046427 | UT 6-HESILED 60 (6,3X32) | UT 6-spec terminal equipped with 60-type HESI LED indicator (6.3×32mm size), providing clear working status feedback, suitable for key 6-spec circuit monitoring |
| 3046414 | UT 6-HESILED 24 (6,3X32) | UT 6-spec terminal with 24V HESI LED indicator (6.3×32mm size), low power consumption, ideal for DC 24V 6-spec circuit status monitoring |
| 3046430 | UT 6-HESILA 250 (6,3X32) | UT 6-spec terminal with 250-type HESI indicator (6.3×32mm size), suitable for high-voltage 6-spec circuit status detection |
| 3046401 | UT 6-HESI (6,3X32) | UT 6-spec terminal with HESI basic status monitoring module (6.3×32mm size), supporting customized status feedback for complex 6-spec systems |
| 3046703 | UT 6-3L | UT 6-spec terminal with 3L three-phase identification design, facilitating correct wiring of three-phase AC 6-spec circuits |
| 3044144 | UT 6 BU | UT 6-spec terminal with blue (BU) appearance, easy to distinguish in dense wiring environments, suitable for 6-spec signal circuit distribution |
| 3044131 | UT 6 | UT 6-spec basic terminal component, high current-carrying capacity, cost-effective choice for general high-load 6-spec industrial circuit connection |
| UT 4 Series (Medium-load Terminal) | ||
| Multi-channel Configuration Models | ||
| 3044364 | UT 4-TWIN | UT 4-spec TWIN dual-channel terminal, suitable for parallel connection of two groups of 4-spec circuits in compact installation spaces |
| 3046168 | UT 4-TG-P/P | UT 4-spec TG-type terminal with P/P dual polarity identification, ideal for dual-polarity 4-spec circuit connection scenarios |
| 3046142 | UT 4-TG | UT 4-spec TG-type basic terminal, suitable for general 4-spec circuit control and signal transmission |
| 3064027 | UT 4-QUATTRO-TG | UT 4-spec QUATTRO four-channel TG-type terminal, designed for large-scale 4-spec circuit distribution in industrial control systems |
| 3064056 | UT 4-QUATTRO-MT P/P | UT 4-spec QUATTRO four-channel MT-type terminal with P/P dual polarity identification, suitable for multi-channel dual-polarity 4-spec circuit connection |
| 3060335 | UT 4-QUATTRO/ 2P-F | UT 4-spec QUATTRO terminal with 2P dual-circuit + F enhanced function, improving control precision of multi-channel 4-spec systems |
| 3060306 | UT 4-QUATTRO/ 2P BU | UT 4-spec QUATTRO terminal with 2P dual-circuit configuration and blue (BU) appearance, facilitating quick identification of 2P circuit groups |
| 3060296 | UT 4-QUATTRO/ 2P | UT 4-spec QUATTRO terminal with 2P dual-circuit configuration, suitable for parallel connection of two groups of four-channel 4-spec circuits |
| 3044584 | UT 4-QUATTRO BU | UT 4-spec QUATTRO four-channel terminal with blue (BU) appearance, ideal for multi-channel 4-spec signal circuit distribution with visual identification needs |
| 3044571 | UT 4-QUATTRO | UT 4-spec QUATTRO four-channel basic terminal, compact structure, suitable for general multi-channel 4-spec industrial circuit connection |
| Status Monitoring Models | ||
| 3214321 | UT 4-PE/L/HESILED 24 (5X20) 120KOHM | UT 4-spec terminal with PE grounding + L-phase identification + 24V HESI LED indicator (5×20mm size), 120KΩ matching resistance, suitable for high-precision 4-spec circuit safety monitoring |
| 3214366 | UT 4-L/HESILED 24 (5X20) 120KOHM | UT 4-spec terminal with L-phase identification + 24V HESI LED indicator (5×20mm size), 120KΩ resistance, designed for 4-spec circuit phase and status monitoring |
| 3214368 | UT 4-L/HESILA 250 (5X20) | UT 4-spec terminal with L-phase identification + 250-type HESI indicator (5×20mm size), suitable for high-voltage 4-spec circuit phase monitoring |
| 1044423 | UT 4-L/HESI (5X20) GY | UT 4-spec terminal with L-phase identification + HESI module (5×20mm size), gray (GY) appearance, ideal for 4-spec circuit phase and status detection |
| 3214325 | UT 4-L/HESI (5X20) | UT 4-spec terminal with L-phase identification + HESI basic module (5×20mm size), suitable for general 4-spec circuit phase monitoring |
| 3046126 | UT 4-HESILED 60 (5X20) | UT 4-spec terminal with 60-type HESI LED indicator (5×20mm size), suitable for key 4-spec circuit status monitoring |
| 1021497 | UT 4-HESILED 24 (5X20)-EX | UT 4-spec terminal with 24V HESI LED indicator (5×20mm size), explosion-proof (EX) grade, designed for hazardous environment 4-spec circuit monitoring |
| 3074172 | UT 4-HESILED 24 (5X20) GY | UT 4-spec terminal with 24V HESI LED indicator (5×20mm size), gray (GY) appearance, suitable for 4-spec circuit status monitoring with visual identification needs |
| 3046537 | UT 4-HESILED 24 (5X20) BU | UT 4-spec terminal with 24V HESI LED indicator (5×20mm size), blue (BU) appearance, ideal for 4-spec signal circuit status monitoring |
| 3046090 | UT 4-HESILED 24 (5X20) | UT 4-spec terminal with 24V HESI LED indicator (5×20mm size), cost-effective choice for general 4-spec circuit status monitoring |
| 1021495 | UT 4-HESILA 250 (5X20)-EX | UT 4-spec terminal with 250-type HESI indicator (5×20mm size), explosion-proof (EX) performance, suitable for hazardous environment high-voltage 4-spec circuit monitoring |
| 3046100 | UT 4-HESILA 250 (5X20) | UT 4-spec terminal with 250-type HESI indicator (5×20mm size), suitable for general high-voltage 4-spec circuit status detection |
| 1021498 | UT 4-HESI (5X20)-EX | UT 4-spec terminal with HESI basic module (5×20mm size), explosion-proof (EX) grade, designed for hazardous environment 4-spec circuit status feedback |
| 3074169 | UT 4-HESI (5X20) GY | UT 4-spec terminal with HESI basic module (5×20mm size), gray (GY) appearance, suitable for general 4-spec circuit status monitoring |
| 3046032 | UT 4-HESI (5X20) | UT 4-spec terminal with HESI basic status monitoring module (5×20mm size), compatible with most 4-spec industrial control systems |
| Special Function Models | ||
| 3044128 | UT 4-PE | UT 4-spec terminal with PE protection grounding function, enhancing electrical safety in medium-load 4-spec industrial circuit connection |
| 3046171 | UT 4-MT-P/P | UT 4-spec MT-type terminal with P/P dual polarity identification, suitable for multi-terminal dual-polarity 4-spec circuit connection |
| 3046236 | UT 4-MTD-DIO/R-L | UT 4-spec MTD-type terminal with DIO digital interface and R-L signal direction identification, ideal for industrial automation 4-spec signal transmission |
| 3046346 | UT 4-MTD-DIO/L-R-P/P | UT 4-spec MTD-type terminal with DIO digital interface, L-R signal direction and P/P polarity identification, suitable for high-precision 4-spec digital control scenarios |
| 3046210 | UT 4-MTD-DIO/L-R | UT 4-spec MTD-type terminal with DIO digital interface and L-R signal direction identification, suitable for general 4-spec digital circuit connection |
| 3046184 | UT 4-MTD | UT 4-spec MTD-type basic terminal, compact structure, suitable for space-limited 4-spec circuit control |
| 3046139 | UT 4-MT | UT 4-spec MT-type multi-terminal terminal, supporting parallel connection of multiple 4-spec circuits, ideal for dense wiring environments |
| 3046252 | UT 4-HEDI-P/P | UT 4-spec terminal with HEDI high-precision detection function and P/P polarity identification, suitable for 4-spec circuit precision control scenarios |
| 3046249 | UT 4-HEDI | UT 4-spec terminal with HEDI basic detection function, designed for 4-spec circuit signal detection and feedback |
| 3045606 | UT 4/ 1P-PE | UT 4-spec 1P single-circuit terminal with PE grounding function, suitable for single-circuit 4-spec signal circuit connection with safety requirements |
| 3045583 | UT 4/ 1P | UT 4-spec 1P single-circuit basic terminal, cost-effective choice for general single-circuit 4-spec circuit connection |
| Basic Models | ||
| 3045101 | UT 4 OG | UT 4-spec terminal with orange (OG) appearance, facilitating quick identification of main circuits in complex wiring systems |
| 3044115 | UT 4 BU | UT 4-spec terminal with blue (BU) appearance, suitable for 4-spec signal circuit distribution with visual identification needs |
| 3044102 | UT 4 | UT 4-spec basic terminal component, balanced current-carrying capacity and installation space, suitable for general medium-load 4-spec industrial circuit connection |
2. Quick Interpretation of UT Series Model Naming Rules
Mastering the naming logic can help you quickly identify the core parameters and applicable scenarios of the product:
- Series Prefix & Spec
- UT: Phoenix dedicated industrial terminal series, focusing on circuit connection, signal distribution and status monitoring.
- 6/4: Core current-carrying specification of the terminal. UT 6 is for high-load industrial circuits; UT 4 is for medium-load control and signal circuits.
- Function Suffix Mark
- HV: High-voltage adaptation, suitable for high-voltage industrial circuit connection scenarios.
- PE: Protection grounding function, enhancing the electrical safety of the circuit.
- HESILED/HESILA/HESI: Status monitoring function series. HESILED is LED indicator (with voltage specification), HESILA is high-voltage indicator, HESI is basic monitoring module; the following (XX×XX) is the indicator size.
- EX: Explosion-proof grade, suitable for hazardous industrial environments with flammable and explosive risks.
- TWIN/QUATTRO: Multi-channel configuration. TWIN is dual-channel, QUATTRO is four-channel, adapting to multi-circuit parallel connection needs.
- TG/MT/MTD: Terminal structure type, TG is general type, MT is multi-terminal type, MTD is digital interface integrated type.
- DIO: Digital input/output interface, with signal direction identification (R-L/L-R), suitable for industrial automation system connection.
- 3L/L: Phase identification function, 3L is three-phase, L is single-phase, ensuring correct AC circuit wiring.
- F/HEDI: Enhanced function, F improves control precision, HEDI realizes high-precision signal detection.
- P/P: Dual polarity identification, suitable for dual-polarity circuit connection scenarios.
- Appearance & Size Parameter
- BU/OG/GY: Color coding, blue/orange/gray appearance facilitates quick circuit identification in complex wiring environments.
- (6,3X32)/(5X20): Size of the status indicator module in millimeters, determining the installation compatibility with the terminal.
- 120KOHM: Matching resistance parameter, tailored for high-precision circuit monitoring scenarios.
3. Core Advantages of Phoenix UT Series Terminals
- Diversified Spec & Channel ConfigurationCovers UT 6 high-load and UT 4 medium-load two core specs, plus TWIN dual-channel and QUATTRO four-channel multi-channel configurations, meeting the connection needs of high-power main circuits, medium-load control circuits and multi-channel signal systems in industrial systems.
- Rich Extended Function SupportIntegrates protection grounding, status monitoring (with explosion-proof option), phase identification, digital interface and polarity identification functions, adapting to complex industrial application scenarios such as hazardous environment monitoring, digital control and three-phase wiring.
- Clear Visual Identification DesignProvides multiple color coding options (BU/OG/GY) and phase identification marks, facilitating quick circuit distinction and maintenance in dense wiring environments, reducing wiring errors and maintenance time.
- Strong Compatibility & Easy InstallationAdopts standard industrial mounting dimensions, compatible with Phoenix's mounting rails and accessories, realizing quick plug-in and replacement, suitable for dense wiring environments in control cabinets.
- Industrial-grade Reliable PerformancePasses strict high-temperature, high-humidity and vibration resistance tests, with stable operation in harsh industrial environments; explosion-proof models comply with hazardous environment safety standards, ensuring long-term reliable work of the circuit connection system.
4. Product Selection Suggestions
- Spec Matching According to Current Load
- For high-power industrial main circuits (such as motor power supply): Select UT 6 series models.
- For medium-load control and signal circuits (such as sensor connection): Choose UT 4 series models.
- Channel Configuration Selection Based on Circuit Quantity
- For multi-circuit parallel connection: Select TWIN dual-channel models for small-scale parallel; choose QUATTRO four-channel models for large-scale distribution.
- For single-circuit or simple dual-circuit connection: Adopt basic UT 6/UT 4 models to reduce costs.
- Function Selection Based on Scenario Requirements
- For hazardous environment circuit monitoring: Prioritize models with EX explosion-proof suffix + HESILED/HESI status monitoring function.
- For circuit safety requirements: Select models with PE protection grounding suffix.
- For industrial automation digital control: Choose models with DIO digital interface suffix, and match the signal direction (R-L/L-R) according to the system requirements.
- For three-phase AC circuit wiring: Select UT 6-3L model with three-phase identification function.
- For dual-polarity circuit connection: Adopt models with P/P polarity identification suffix.
- Identification & Cost Optimization
- For complex wiring systems: Select color-coded models (BU/OG/GY) to improve maintenance efficiency.
- For general non-critical circuits: Choose basic structure models without additional function suffixes (such as UT 6, UT 4) to reduce procurement costs.
Phoenix UT Series Terminal Components Product Selection Guide