Phoenix MINI MCR-2-RPS-2I-2I-OLP-PT-feed isolator 2906449, the 2-terminal feed isolator powered by the dual-channel output loop adopts plug-in connection technology for electrical isolation and filtering of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Plug-in connection technology.
| Product Type | Feeder Isolator |
| product series | MINI Analog Pro |
| Channels | 2 |
| Model | isolation amplifier |
| insulation characteristics: GB Standard | |
| Overvoltage Category | II |
| pollution level | 2 |
| electrical isolation | 2 road isolation |
| galvanic isolation between input and output | is |
| cut-off frequency (3dB) | 100Hz |
| signal transmission behavior | In = Out |
| maximum temperature coefficient | ≤ 0.001 %/K |
| Maximum transmission error | ≤ 0.1 % (5 V) |
| Electrical isolation input/output/power supply | |
| Rated insulation voltage | 300Vrms |
| Test Voltage | 3 kV AC (50 Hz, 60 s) |
| insulation | reinforced insulation conforming to IEC/EN 61010-1 |
| Power | |
| Supply Voltage Range | 8V DC ... 30V DC (loop power supply, no external power supply required) |
| power consumption | 600 mW (25 mA) |
| signals: current | |
| Number of inputs | 2 |
| configurable/programmable | No |
| current input signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA | |
| voltage loss | 3.1V (I = 20 mA) |
| Transmitter supply voltage | UA- 5V |
| additional error, depending on input voltage | (UA- 5 V) x 0.06% |
| signals: current | |
| outputs | 2 |
| configurable/programmable | No |
| current output signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA | |
| response current | 200 µA |
| voltage loss | 3.1V (I = 20 mA) |
| load/output load current output | 600 Ω |
| Connection Mode | in-line connection |
| stripping length | 10mm |
| Rigid conductor cross section | 0.2 mm² ... 2.5 mm² (with cold press head) |
| 0.14 mm² ... 2.5 mm² (without cold head) | |
| Flexible Wire Cross Section | 0.14 mm² ... 2.5 mm² |
| Attachable Guide Cross Section AWG | 24 ... 12 (flexible) |