Phoenix PLC-PT-ELR W1/2-24DC-commutating load relay 1069556,PLC-INTERFACE used as an electronic reverse load relay, including PLC-BPT.../21 base terminal, using plug-in interface and with integrated circuit, used to drive DC Motor, with LED display and protection circuit, output: 10V DC ... 30V DC/2 A
| Product Type | solid state contactor |
| product series | PLC-INTERFACE |
| Mode of operation | 100% operating factor |
| insulation characteristics: electrical clearance and creepage distance between power supply circuits | |
| insulation | Foundation Isolation |
| Overvoltage Category | II |
| pollution level | 2 |
| phase number | 1 |
| rated conditions | 0.4W |
| Electrical clearance and creepage distance between power supply circuits | |
| Rated insulation voltage | 50V |
| Rated overvoltage | 0.5 kV |
| power supply | |
| Enter Name | Equipment power supply |
| Rated control circuit supply voltage US | 24V DC |
| Control Supply Voltage Range | 19.2V DC ... 28.8V DC |
| control | |
| Enter Name | Control Input Right/Left |
| Rated operating voltage UC | 24V DC |
| Trigger voltage range | 19.2V DC ... 28.8V DC |
| Rated operating current IC | 3 mA |
| Typical Response Time | 200 µs |
| protection circuit | polarity protection |
| Surge Protection | |
| overvoltage protection | > 33V DC |
| transmission frequency | 300Hz |
| switching time RL/LL(open time) | 80 ms |
| DC output | |
| Considerations | used at the output to protect the supply voltage. |
| Rated operating voltage Ue | 24V DC |
| Operating voltage range | 10V DC ... 30V DC |
| Rated operating current (load output) | 2 A |
| load current | 2 A |
| quiescent current | 10 mA |
| protection circuit | polarity protection; polarity protection diode (non-continuous polarity protection) |
| Surge Protection | |
| overvoltage protection | > 33V DC |