Phoenix PSR-M-B2-SDI8-SDO4-DO4-PI-safety module 1104975, configurable safety module (basic module), with 8 safety inputs, 4 safety outputs, 4 reset inputs or 4 signal outputs, 4 clock outputs, can be extended by TBUS, Up to SIL 3, Cat. 4/PL e, safety level, in-line terminal, no TBUS connector included

Product Type safety equipment
Application Emergency stop button
grating
safety door
Safety Shutdown
control Single and Dual Channel
insulation characteristics
protection level III (EN 50178)
insulation characteristics
Overvoltage Level II
pollution level 2
response time see user manual
restart time min. 5 s (start-up time)
max. 10 s (start-up time)

rated conditions 7.1W (with maximum allowable load)
Rated operating mode 100% Eligible
Interface DIN rail TBUS is used to connect the main station module, which is not included in the standard scope of supply
rated overvoltage/insulation 4 kV basic safety isolation between all current paths and enclosure
Power
Name A1/A2
Rated control circuit supply voltage US 19.2V DC ... 28.8V DC
Rated control circuit supply voltage US 24V DC-20%/+ 20% (external protection provided, typical 5 A)
Rated control supply current IS Typical 55 mA (output inactive)
Typical 135 mA (output enabled, no load)
US Typical 1.32W (output inactive)
Impulse current < 2.3 A (&Delta;t = 1 ms Us)
filter time typical 5 ms (at A1, at the voltage dip Us)
protection circuit series protection to prevent polarity reversal

digital quantities: IN1, IN2, IN3, IN4, IN5, IN6, IN7, IN8
Input Description safety-related digital inputs
IEC 61131-2 Type 2
Input Quantity 8
input voltage range, "0" signal 0V DC ... 5V DC
input voltage range, "1" signal 11V DC ... 28.8V DC
Input current range "0" signal < 1 mA
filter time 3 ms ± 2 ms minimum (settable)
max. 250 ms ± 2 ms (settable)
test pulse rate ≥ 2x set filter time, minimum test pulse rate = 10 ms
Cable Length 100 m max (per input)
Allowable Total Conductor Resistance max. 1.2 kΩ (US)
power consumption typical value 10 mA (in UStypical)
maximum 12.1 mA (when the control voltage is 28.8V DC)
digital quantity: reset input (FBK)
Input Description configurable (as signal output or reset input)
IEC 61131-2 Type 2
Input Quantity 4
input voltage range, "0" signal 0V DC ... 5V DC
1104975

Phoenix PSR-M-B2-SDI8-SDO4-DO4-PI-Security Module 1104975

Product Center