Phoenix PSR-CT-C-SEN-1-8-safety switch sensor 2702972, proximity safety circuit up to Cat. 4, PL e (EN ISO 13849), SIL 3 (IEC 61508), single code sensor with RFID coding, mode 4 (EN ISO 14119), automatic or manual start, integrated diagnostic function, 24V DC power supply, IP69K,M12 connector

Product Type safety switch
product series PSR-CT
Application Security door monitoring
position monitoring
Technology answering machine
insulation characteristics
protection level III
insulation characteristics
pollution level 3
Difference Time max. 10 ms (between safe outputs)
impact suppression typical 5 s (after opening UB)
Suction time max. 400 ms (for safety output)
Risk Time Max. 125 ms (stand-alone device)
Test Pulse Typical 300 & micro;s (test pulse duration)
approx. 100 ms (test pulse period)
delay time Typical 10 ms (risk time delay per device)

Switching frequency max. 1Hz
short-circuit current Typical 100 A (condition short-circuit current)
Switching frequency max. 1Hz
Rated insulation voltage max. 300V
Rated overvoltage Max. 1.5 kV
power supply
supply voltage 24V DC ± 15% (PELV, controlled, residual voltage ripple <5%)
power consumption max. 40 mA
protection minimum 0.25 A (externally executed)
max. 8 A (external execution required)
Contact Type 2 safe digital outputs
2 safe digital outputs

signal
Name DGN
Output Description p wiring
outputs 1
output voltage (UB- 1.5V (HIGH))
Max (UB(HIGH))
Minimum 0V DC (LOW)
Max 1V DC (LOW)
current 1 mA minimum
max. 50 mA
Short-circuit protection is
Safety Output
Name FO1A, FO1B
Output Description P-type semiconductor output
outputs 2
output voltage (UB- 1.5V (HIGH FO1A, FO1B))
Max (UB(HIGH FO1A, FO1B))
Minimum 0V DC (LOW FO1A/FO1B)
Max 1V DC (LOW FO1A/FO1B)
switching current minimum 1 mA (per safety output)
maximum 150 mA (per safety output)
residual flow ≤ 0.25 mA
Category of use according to IEC 60947-5-2 150 mA (24V (DC13))