Phoenix PSR-MC40-3NO-1DO-24DC-SP-safety relay 2700570, safety relay, used for emergency stop, safety door and grating, safety level up to SIL 3, Cat. 4, PL e, single-channel or dual-channel operation, automatic or manual, controlled Start, 3 enable current paths, US = 24V DC, pluggable in-line terminals

Product Type safety relay
Product Series PSRmini
Application Emergency stop button
safety door
grating
electromagnetic switch
answering machine
control dual channel
Relay Model Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3
insulation characteristics
Overvoltage Level III
pollution level 2
Typical Response Time < 175 ms (auto start)
< 175 ms (manual, monitoring start)
Typical startup time (Us) < 250 ms (when controlled via A1)
Typical release time < 20 ms (via sensor loop as required)
< 20 ms (as required, via A1)
restart time < 1 s (start-up time)
Recovery Time < 500 ms
Start Pulse Length ≥ 500 ms (manual reset)

rated conditions 4.8W (US= 26.4 V, IL² = 48 A²,PTotal max= 2.4W +2.4 W)
Rated operating mode 100% Eligible
Rated insulation voltage 250V AC
rated overvoltage/insulation See chapter "Insulation Coordination"
power supply
Name A1/A2
Rated control circuit supply voltage US 20.4V DC ... 26.4V DC
Rated control circuit supply voltage US 24V DC -15 % / +10%
Rated control supply current IS 80 mA typical
US Typical 1.92W
Impulse current typical 5 A (& Delta;t = 200 & micro;s Us)
filter time 1 ms (at A1, at the voltage dip Us)
protection circuit series protection to prevent polarity reversal; suppression diode

digital quantity: sensor circuit (S12,S22)
Input Description safety-related sensor inputs
Input Quantity 2
input voltage range, "0" signal 0V DC ... 5V DC (for safety shutdown; at S12 and S22)
Input current range "0" signal 0 mA ... 2 mA (for safety shutdown; at S12 and S22)
Impulse current < 20 mA (S12 input, the voltage is usually US)
< 5 mA (S22 input, voltage is usually US)
filter time max. 1.5 ms (test pulse width of low test pulse)
test pulse rate = 5 x test pulse width
parallel
Allowable Total Conductor Resistance 150 Ω
protection circuit Suppressor Diode
power consumption < 5 mA (in UStypical)
digital quantity: starting circuit (S34)
Input Description non-safety related
2700499