Phoenix PSR-MS30-1NO-24DC-SC-safety relay 2904952, safety relay for emergency stop and safety door, meets SILCL 3,Cat. 4. PL e,1 or 2 channel operation, automatic start, cross circuit detection, 1 start current path, Us = 24V DC, fixed screw connector

Product Type safety relay
product series PSRmini
Application Emergency stop button
safety door
electromagnetic switch
answering machine
control Single and Dual Channel
Relay Model Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3
insulation characteristics
Overvoltage Level III
pollution level 2
Typical Response Time < 175 ms
Typical startup time (Us) < 250 ms (when controlled via A1)
Typical release time < 20 ms (when controlled via A1 or S12 and S22)
restart time 1 s (start-up time, after supply voltage is applied)
Recovery Time < 500 ms

rated conditions 3W (US= 26.4 V, IL² = 36 A²,PTotal max= 1.2W +1.8 W)
Rated operating mode 100% Eligible
Rated insulation voltage 250V AC
rated overvoltage/insulation input circuit and normally open safety contact output
4 kV foundation safety isolation between all current paths and enclosure
Power
Name A1/A2
Rated control circuit supply voltage US 20.4V DC ... 26.4V DC
Rated control circuit supply voltage US 24V DC -15 % / +10%
Rated control supply current IS Typical 42 mA
US Typical 1W
Impulse current 4.5 A (&Delta;t < 120 &micro;s Us)
filter time 1 ms (at A1, at the voltage dip Us)
protection circuit Surge protection; Suppressor diode
series protection to prevent polarity reversal

digital quantity: sensor circuit (S12,S22)
Input Description safety-related sensor inputs
Input Quantity 2
input voltage range, "0" signal 0V DC ... 5V DC (for safety shutdown; at S12)
input voltage range, "1" signal 20.4V DC ... 26.4V DC
Input current range "0" signal 0 mA ... 2 mA (for safety shutdown; at S12)
Impulse current < 20 mA (S12 input, the voltage is usually US)
< 5 mA (S22 input, voltage is usually US)
> -15 mA (typically USS22/0 V)
filter time max. 1.5 ms (test pulse width of low test pulse)
test pulse rate = 5 x test pulse width
Allowable Total Conductor Resistance 150 Ω
protection circuit suppression diode
power consumption < 5 mA (Us/Ixto S12)
< 5 mA (Us/Ixto S22)
> -5 mA (Us/Ixto S22/0V)
digital quantity: starting circuit (S35)
Input Description non-safety related
Input Quantity 1
input voltage range, "1" signal 20.4V DC ... 26.4V DC
Impulse current < 10 mA
Allowable Total Conductor Resistance 150 Ω
protection circuit suppression diode
power consumption < 10 mA
2904951

Phoenix PSR-MS30-1NO-24DC-SC-Safety Relays 2904952

Product Center

PRODUCT CENTER