Phoenix EEM-MB371-EIP-measuring device 2907976, multifunctional energy measuring device without display, with direct Roche connection and integrated Modbus/TCP and EtherNet/IP™ interface, for measuring electrical parameters in low-voltage installations up to 690V.

Product Type Electric energy monitoring equipment
Product Series EMpro

rated conditions 10 VA
Main Power Type 3-phase (3 or 4-wire system), dual-phase (2-wire system) and single-phase (single-wire system)
electrical isolation
Test Voltage 4 kV AC (50 Hz, 60 s)
pollution level 2
insulation reinforced insulation
electrical isolation housing relative to all potentials IEC 61010-1
Standards/Regulations IEC 61010-1
Overvoltage Category III (300V AC)
II (600V AC)
insulation reinforced insulation
Electrically isolated power supply with respect to all other potentials IEC 61010-1
Standards/Regulations IEC 61010-1
Overvoltage Category III (300V AC)
II (600V AC)
insulation reinforced insulation
galvanically isolated voltage measurement input relative to all other potentials IEC 61010-2-030
Standards/Regulations IEC 61010-2-030
Measurement Type III (300V AC)
II (600V AC)
insulation reinforced insulation
galvanically isolated digital I/O
insulation Functional insulation
Electrical Isolation Communication Interface
insulation Functional insulation
power supply
Supply Voltage Range 100V AC ... 230V AC (±20 %)
150V DC ... 250V DC (±20 %)
power consumption ≤ 4W
Rated frequency 50Hz ... 60Hz (AC sinusoidal)

Overview
measuring principle True effective value measurement
measured value AC sinusoidal (50Hz/60Hz)
harmonic current acquisition up to 63rd harmonic
Input Description digital input conforming to IEC/EN 61131-2 (type 3)
number. 1
voltage input signal 24V DC
0V DC ... 30V DC
current input signal 2 mA ... 15 mA
protection 250 mA (fast fuse)
protection circuit Prevent wrong DC connection (max. 30V)
measurement: voltage
Enter Name voltage measurement inputs V1,V2,V3
Input Voltage Range Direct 35V AC ... 690V AC (phase/phase)
20V AC ... 400V AC (phase/neutral conductor)
input voltage range via external current transformer 60V AC ... 2000000V AC (Primary)
60V AC ... 400V AC (secondary)
surge power 760V AC (phase/phase)
accuracy 0.2 percent
power consumption < 2 VA
measurement: current
Enter Name current measurement RC1, RC2, RC3
input current ≤ 400 A (measurement level 1)
≤ 4000 A (measurement level 2)
transmission factor: 100 mV/1000 A when using Phoenix Electric coils
Input voltage measurement range 500 &micro;V ... 400 mV
Measurement Range Rating 5 A
2907984

Phoenix EEM-MB371-EIP-Measuring Equipment 2907976