Phoenix PSI-REP-DNET CAN-Repeater 2313423, modular repeater, used to electrically isolate and extend the transmission distance of DeviceNet™, SDS, CANopen®, data rate up to 1 Mbps, can achieve high-quality electrical isolation between interfaces, Support DIN rail installation, 24V DC power supply
Product Type
Interface Interface Converter
MTTF
1091 years (SN 29500 standard, temperature 25°C, duty cycle 21%)
514 years (SN 29500 standard, temperature 40°C, duty cycle 34.25%)
208 years (SN 29500 standard, temperature 40°C, duty cycle 100%)
MTBF
823 years (Telcordia standard, temperature 25°C,21% operation cycle (5 days a week, 8 hours a day))
170 years (Telcordia standard, 40°C,34.25% cycle (5 days a week, 12 hours a day))
electrical isolation
VCC // TBUS // CAN A // CAN B
rated conditions
1.32W
test voltage data interface/power supply
1.5 kVrms(50 Hz,1 min)
Rated insulation voltage
85V DC (conforming to EN/IEC 60079-7, Annex H)
Power
Supply Voltage Range
10V DC ... 30V DC (via plug-in COMBICON screw terminal block)
Rated supply voltage
24V DC
Typical current consumption
55 mA (24V DC)
Maximum current consumption
80 mA
≤ 2 A (via DIN rail connector when running in connection site)
Function
diagnostics and status indicators
LEDs: VCC (supply voltage), NET A(Mod/Net status port A), NET B(Mod/Net status port B), ACT (active/data traffic)
switching
Output Name
relay output
outputs
1
Contact Type
normally closed contact
Minimum Switching Voltage
10V DC
maximum switching voltage
30V DC
limit continuous current
500 mA
Power
stripping length
7.00mm
Tightening torque
0.56 Nm ... 0.79 Nm
-bit distortion, input
± 35%
-bit distortion output
< 6.25%
bit delay
a message length (extended)
signal
CAN
CANopen®
DeviceNet™
data: CAN interface, ISO/IS 11898 compliant, for DeviceNet™, CAN, CANopen®
transmission speed
≤ 1 MBit/s (configurable with DIP switch)
Connection Mode
plug-in COMBICON screw terminal block
Channels
2 (CAN_High / CAN_Low)
Transmission Length
≤ 5000 m (depending on transmission rate and transport protocol used)
INTERBUS equipment quantity
≤ 64 (each potential section)
≤ 63 (DeviceNet™, logically addressable)
≤ 128 (CANopen®, logically addressable)
terminal resistance
124 Ω (integrated and ready to switch)
single wire/wiring point, rigid
0.2 mm² ... 2.5 mm²
single wire/wiring point, flexible
0.2 mm² ... 2.5 mm²
AWG stranded wire, flexible
14
AWG Wire Minimum Cross Section, Flexible
24
single wire/wiring point, maximum rigid AWG
14
Single Wire/End Point, Minimum Rigid AWG
24
stripping length
7mm
transmission medium
2 core twisted pair, shielded
transmission technology
CSMA/CA
File Format/Encoding
bit padding, NRZ
data: CAN interface, ISO/IS 11898 compliant, for DeviceNet™, CAN, CANopen®
transmission speed
≤ 1 MBit/s (configurable with DIP switch)
Connection Mode
plug-in COMBICON screw terminal block
Channels
2 (CAN_High / CAN_Low)
Transmission Length
≤ 5000 m (depending on transmission rate and transport protocol used)