Phoenix ELR H3-IES-PT-24DC/500AC-9-T-Hybrid Motor Starter 2906064, Hybrid Motor Starter; Function: Start Motor, Motor Protection (Class 10A), Emergency Stop Button, Higher Transient Voltage Tolerance, ATEX; Input: 24V DC; Output: 3 ~, 500V AC, 9 A; In-line connection

Product Type hybrid motor starter
Product Series CONTACTRON
Mode of operation 100% operating factor

phase number 3
Motor Starter Type direct starter
Switching frequency ≤ 2Hz (depending on load)
rated conditions 13.5W
Switching frequency ≤ 2Hz (depending on load)
Maximum power loss 14.6W
minimum power loss 1.1W
type of coordination 1
Power
Rated control circuit supply voltage US 24V DC
Control Supply Voltage Range 19.2V DC ... 30V DC
Rated control supply current IS 40 mA
protection circuit surge protection
polarity protection
insulation characteristics
Rated insulation voltage 500V
Rated overvoltage 6 kV
Overvoltage Level III
pollution level 2
control input and control supply voltage and insulation characteristics from auxiliary circuit to main circuit safety insulation (IEC 60947-1/EN 50178) for operating voltages ≤ 300V AC
operating voltage 300V AC ... 500V AC (IEC 60947-1)
safety insulation (EN 50178), suitable for working voltage 300 ... 500V AC
control input and control supply voltage to auxiliary circuits safety insulation (IEC 60947-1),≤ 300V AC in auxiliary circuits
safety insulation (EN 50178), in auxiliary circuits ≤ 300V AC
emergency trip
Operating Threshold > 45 A
response time 2 s

control
Enter Name Control Input
Rated operating voltage UC 24V DC
Trigger voltage range 19.2V DC ... 30V DC
Rated operating current IC 5 mA
Switch Threshold 9.6V ("0" signal)
19.2V ("1" signal)
switch level < 5V DC (for emergency stop)
Typical closing time < 30 ms
protection circuit polarity protection

AC output
Rated operating voltage Ue 500V AC
Operating voltage range 42V AC ... 550V AC
Rated operating current Ie 9 A (AC-51)
6.5 A (AC-53a)
mains frequency 50/60Hz
Load current range 1.5 A ... 9 A (see decay curve)
action characteristics according to IEC 60947-4-2 Class 10A
cooling time 20 min
leakage current 0 mA
protection circuit surge protection
Confirm Output
Considerations confirmation: floating transfer contact, signal contact
Contact Type 1 changeover contact
switching capacity according to IEC 60947-5-1 3 A (230 V, AC15)
2 A (24V (DC13))

control loop
Connection Mode in-line connection
stripping length 10mm
Rigid conductor cross section 0.2 mm² ... 2.5 mm²
Flexible Wire Cross Section 0.2 mm² ... 2.5 mm²
Attachable Guide Cross Section AWG 24 ... 14
Load Circuit
Connection Mode in-line connection
stripping length 10mm
Rigid conductor cross section 0.2 mm² ... 2.5 mm²
Flexible Wire Cross Section 0.2 mm² ... 2.5 mm²
Attachable Guide Cross Section AWG 24 ... 14

Status Display LED (yellow)
Operating voltage display Green LED
error indication Red LED