Phoenix ELR H5-I-PT- 24DC/500AC-9-P-hybrid motor starter 2909560, the hybrid motor starter can replace the traditional reversing contactor. Reverse start a 3-phase AC motor with a rated current of 9 A and provide motor protection. Power supply and relay extension are possible via DIN rail connectors.

Product Type hybrid motor starter
Product Series CONTACTRON
Mode of operation 100% operating factor

phase number 3
Motor Starter Type reversible starter
Switching frequency ≤ 2Hz (depending on load)
Switching frequency ≤ 2Hz (depending on load)
maximum power loss 7W
minimum power loss 0.88W
type of coordination 1
Power
Rated control circuit supply voltage US 24V DC
Control Supply Voltage Range 19.2V DC ... 30V DC
Rated control supply current IS 60 mA
protection circuit surge protection
polarity protection; parallel polarity protection diode
insulation characteristics
Rated insulation voltage 550V
Rated overvoltage 6 kV
Overvoltage Level III
pollution level 2
control input and control supply voltage and insulation characteristics from auxiliary circuit to main circuit safety insulation (IEC 60947-1)
control input and control supply voltage to auxiliary circuits safety insulation (IEC 60947-1),≤ 300V AC in auxiliary circuits
emergency trip
Operating Threshold > 60 A
response time < 0.5 s

control
Enter Name Control Input Right/Left
Rated operating voltage UC 24V DC
Trigger voltage range 19.2V DC ... 30V DC
Rated operating current IC 7 mA
Switch Threshold 9.6V ("0" signal)
19.2V ("1" signal)
Typical closing time < 30 ms
protection circuit polarity protection

AC output
Rated operating voltage Ue 500V AC
Operating voltage range 42V AC ... 550V AC
Rated operating current Ie 9 A (AC-51)
7 A (AC-53a)
mains frequency 50/60Hz
Load current range 1.5 A ... 9 A
action characteristics according to IEC 60947-4-2 Class 10 (≤ 3 A)
Class 10A (> 3 A)
cooling time 20 min (for automatic reset)
leakage current 0 mA
protection circuit Surge protection; Varistor
Confirm Output
Considerations confirmation: floating transfer contact, signal contact
Contact Type 1 changeover contact
switching capacity according to IEC 60947-5-1 2 A (24V (DC13))

control loop
Connection Mode in-line connection
stripping length 10mm
Rigid conductor cross section 0.2 mm² ... 2.5 mm²
Flexible Wire Cross Section 0.2 mm² ... 2.5 mm²
Attachable Guide Cross Section AWG 24 ... 14
Load Circuit
Connection Mode in-line connection
stripping length 10mm
Rigid conductor cross section 0.2 mm² ... 2.5 mm²
Flexible Wire Cross Section 0.2 mm² ... 2.5 mm²
Attachable Guide Cross Section AWG 24 ... 14
2900421

Phoenix ELR H5-I-PT- 24DC/500AC-9-P-Hybrid Motor Starter 2909560