Phoenix ELR H5-IS-PT- 24DC/500AC-3-P-hybrid motor starter 2909569, the hybrid motor starter can replace the traditional reverse contactor. Reverse start a 3-phase AC motor up to 3 A, providing motor protection and emergency stop with a safety integrity level of SIL 3/PL e. Grouped shutdown, power supply and relay expansion can be achieved through DIN rail connectors.
| Product Type | hybrid motor starter |
| Product Series | CONTACTRON |
| Mode of operation | 100% operating factor |
| phase number | 3 |
| Motor Starter Type | reversible starter |
| Switching frequency | ≤ 2Hz (depending on load) |
| Switching frequency | ≤ 2Hz (depending on load) |
| Maximum power loss | 4.1W |
| minimum power loss | 0.88W |
| type of coordination | 1 |
| Power | |
| Rated control circuit supply voltage US | 24V DC |
| Control Supply Voltage Range | 19.2V DC ... 30V DC |
| Rated control supply current IS | 60 mA |
| protection circuit | surge protection |
| polarity protection | |
| insulation characteristics | |
| Rated insulation voltage | 550V |
| Rated overvoltage | 6 kV |
| Overvoltage Level | III |
| pollution level | 2 |
| control input and control supply voltage and insulation characteristics from auxiliary circuit to main circuit | safety insulation (IEC 60947-1) |
| control input and control supply voltage to auxiliary circuits | safety insulation (IEC 60947-1),≤ 300V AC in auxiliary circuits |
| emergency trip | |
| Operating Threshold | > 33 A |
| response time | < 0.5 s |
| control | |
| Enter Name | control inputs: right/left and enable inputs |
| Considerations | The enable input is compatible with the blanking signal (semiconductor output signal, test pulse duration not exceeding 3 ms), A turn-on pulse of up to 4 ms is permitted without adversely affecting the safety function. |
| Rated operating voltage UC | 24V DC |
| Trigger voltage range | 19.2V DC ... 30V DC |
| Rated operating current IC | 7 mA |
| Switch Threshold | 9.6V ("0" signal) |
| 19.2V ("1" signal) | |
| switch level | < 5V DC (for emergency stop) |
| Typical closing time | < 30 ms |
| protection circuit | polarity protection |
| AC output | |
| Rated operating voltage Ue | 500V AC |
| Operating voltage range | 42V AC ... 550V AC |
| Rated operating current Ie | 3 A (AC-51) |
| 3 A (AC-53a) | |
| mains frequency | 50/60Hz |
| Load current range | 180 mA ... 3 A |
| action characteristics according to IEC 60947-4-2 | Class 10 |
| cooling time | 20 min (for automatic reset) |
| leakage current | 0 mA |
| protection circuit | Surge protection; Varistor |
| Confirm Output | |
| Considerations | confirmation: floating transfer contact, signal contact |
| Contact Type | 1 changeover contact |
| switching capacity according to IEC 60947-5-1 | 2 A (24V (DC13)) |
| control loop | |
| Connection Mode | in-line connection |
| stripping length | 10mm |
| Rigid conductor cross section | 0.2 mm² ... 2.5 mm² |
| Flexible Wire Cross Section | 0.2 mm² ... 2.5 mm² |
| Attachable Guide Cross Section AWG | 24 ... 14 |
| Load Circuit | |
| Connection Mode | in-line connection |
| stripping length | 10mm |
| Rigid conductor cross section | 0.2 mm² ... 2.5 mm² |
| Flexible Wire Cross Section | 0.2 mm² ... 2.5 mm² |
| Attachable Guide Cross Section AWG | 24 ... 14 |