Phoenix ELR W3-230AC/500AC-2I-hybrid motor starter 2297044, hybrid motor starter, used for reverse starting 3-phase AC motors, up to 500V AC and 2 A output current, 230V AC control voltage, Adjustable overload shutdown, emergency stop function up to SIL 3/PL e and screw connection

Product Type hybrid motor starter
Product Series CONTACTRON
Mode of operation 100% operating factor

phase number 3
Motor Starter Type reversible starter
Switching frequency ≤ 2Hz (depending on load)
rated conditions 2.2W
Switching frequency ≤ 2Hz (depending on load)
maximum power loss 4.7W
minimum power loss 2.6W
Power
Rated control circuit supply voltage US 230V AC
Control Supply Voltage Range 92V AC ... 253V AC
Rated control supply current IS 4 mA
mains frequency 40/100Hz
protection circuit surge protection
insulation characteristics
Rated insulation voltage 500V
Rated overvoltage 6 kV
Overvoltage Level III
pollution level 2
control input and control supply voltage and insulation characteristics from auxiliary circuit to main circuit safety insulation (IEC 60947-1) for operating voltages ≤ 300V AC
operating voltage 300V AC ... 500V AC (IEC 60947-1)
control input and control supply voltage to auxiliary circuits safety insulation (IEC 60947-1),≤ 300V AC in auxiliary circuits

control
Enter Name Control Input Right/Left
Rated operating voltage UC 230V AC
Trigger voltage range 92V AC ... 253V AC
Rated operating current IC 7 mA
Switch Threshold 44V AC ("0" signal)
85V AC ("1" signal)
switch level < 5V DC (for emergency stop)
Typical Response Time < 35 ms
Typical closing time < 80 ms

AC output
Rated operating voltage Ue 500V AC
Operating voltage range 42V AC ... 550V AC
Rated operating current Ie 2.4 A (AC-51)
2.4 A (AC-53a)
mains frequency 50/60Hz
Load current range 180 mA ... 2.4 A (see decay curve)
action characteristics according to IEC 60947-4-2 Class 10A
cooling time 20 min (for automatic reset)
leakage current 0 mA
residual pressure < 0.3V
surge current 100 A (t = 10 ms)
protection circuit surge protection
Confirm Output
Considerations confirmation: floating transfer contact, signal contact
Contact Type 1 changeover contact
switching capacity according to IEC 60947-5-1 3 A (230 V, AC15)
2 A (24V (DC13))
residual pressure < 0.5V

control loop
Connection Mode screw connection
stripping length 8mm
thread M3
Rigid conductor cross section 0.2 mm² ... 2.5 mm²
Flexible Wire Cross Section 0.2 mm² ... 2.5 mm²
Attachable Guide Cross Section AWG 24 ... 14
Tightening torque 0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.
2900421

Phoenix ELR W3-230AC/500AC- 2I-Hybrid Motor Starter 2297044

Product Center